Optimization of a liquid injection NH3/CO2 cascade refrigeration system. Energetic, exergetic and environmental assessment

被引:0
|
作者
Hamzaoui, Malek [1 ]
Grine, Ali [2 ]
Tiachacht, Samir [1 ]
Beltagy, Hani [3 ]
机构
[1] Mouloud Mammeri Univ Tizi Ouzou, Lab Mech Struct & Energet LMSE, BPN 17 RP, Tizi Ouzou 15000, Algeria
[2] Mhamed Bougara Univ, Mech Engn Dept, Boumerdes 35000, Algeria
[3] Mouloud Mammeri Univ Tizi Ouzou, Fac Engn Construct, Dept Mech Engn, BPN 17 RP, Tizi Ouzou 15000, Algeria
关键词
Cascade system; NH3/CO2; Liquid injection; Energy and exergy optimization; TEWI; ROTARY-COMPRESSOR; TEMPERATURE; PERFORMANCE; 2-PHASE; SUCTION;
D O I
10.1016/j.psep.2025.106862
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article presents an in-depth numerical study on optimizing the operation of a liquid-injection cascade refrigeration system. The main objective is to determine the optimal operating point that maximizes the COP within the temperature ranges of 30 degrees C <T-C< 60 degrees C and -55 degrees C<T-E< -30 degrees C. A comprehensive mathematical model was developed to simulate the thermodynamic behavior of the system, taking into account the liquid injection processes. Optimization, based on a bio-inspired metaheuristic algorithm (Puma), was used to determine the optimal operating parameters, such as T-3L, the injection pressures and flow rates. The results show that liquid injection significantly improves system performance by reducing energy consumption, exergy destruction, and compressor discharge temperature. Additionally, an environmental analysis based on the Total Equivalent Warming Impact (TEWI) was conducted to assess the environmental impact of the system. The results show that the optimized system has a lower TEWI compared to conventional systems, highlighting its potential for reducing greenhouse gas emissions. Finally, correlations providing T-3(L), injection pressures, flow ratios, and optimal COPs are provided to give valuable information for the design and operation of more efficient and environmentally friendly liquid-injection cascade refrigeration systems.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Thermodynamic analysis of NH3/CO2 cascade refrigeration system with thermosyphon refrigerant cooling screw compressor motor
    Li, Liu
    Yang, Qichao
    Wu, Jiawei
    Li, Liansheng
    Zhang, Yongli
    Zhang, Xiliang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 1 - 13
  • [22] Performance evaluation of NH3/CO2 cascade refrigeration system with ejector subcooling for low-temperature cycle
    Chi, Weikai
    Yang, Qichao
    Chen, Xiaonan
    Liu, Guangbin
    Zhao, Yuanyang
    Li, Liansheng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 162 - 171
  • [23] Exergoeconomic and environmental analyses of CO2/NH3 cascade refrigeration systems equipped with different types of flash tank intercoolers
    Mosaffa, A. H.
    Farshi, L. Garousi
    Ferreira, C. A. Infante
    Rosen, M. A.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 117 : 442 - 453
  • [24] Thermodynamic analysis of optimal condensing temperature of cascade-condenser in CO2/NH3 cascade refrigeration systems
    Lee, Tzong-Shing
    Liu, Cheng-Hao
    Chen, Tung-Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (07): : 1100 - 1108
  • [25] ENERGETIC AND EXERGETIC STUDIES OF MODIFIED CO2 TRANSCRITICAL REFRIGERATION CYCLES
    Shet, Shrikant
    Patil, Omprakash
    Agrawal, Neeraj
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 186 - 193
  • [26] Energetic and exergetic studies of modified CO2 transcritical refrigeration cycles
    Patil, Omprakash S.
    Shet, Shrikant A.
    Jadhao, Manish
    Agrawal, Neeraj
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (01) : 171 - 180
  • [27] Energy and exergy analysis of NH3/CO2 cascade refrigeration system with subcooling in the low-temperature cycle based on an auxiliary loop of NH3 refrigerants
    Chen, Xiaonan
    Yang, Qichao
    Chi, Weikai
    Zhao, Yuanyang
    Liu, Guangbin
    Li, Liansheng
    ENERGY REPORTS, 2022, 8 : 1757 - 1767
  • [28] A FEASIBILITY ANALYSIS OF REPLACING THE STANDARD AMMONIA REFRIGERATION DEVICE WITH THE CASCADE NH3/CO2 REFRIGERATION DEVICE IN THE FOOD INDUSTRY
    Jankovich, Dennis
    Osman, Kresimir
    THERMAL SCIENCE, 2015, 19 (05): : 1821 - 1833
  • [29] ABINITIO PREDICTION OF PROPERTIES OF CO2, NH3, AND CO2=NH3
    AMOS, RD
    HANDY, NC
    KNOWLES, PJ
    RICE, JE
    STONE, AJ
    JOURNAL OF PHYSICAL CHEMISTRY, 1985, 89 (11): : 2186 - 2192
  • [30] Performance evaluation and optimal configuration analysis of a CO2/NH3 cascade refrigeration system with falling film evaporator-condenser
    Ma, Ming
    Yu, Jianlin
    Wang, Xiao
    ENERGY CONVERSION AND MANAGEMENT, 2014, 79 : 224 - 231