Verification of dose and dose rate for quality assurance of spread-out-Bragg-peak proton FLASH radiotherapy using machine log files

被引:0
作者
Oliaei Motlagh, Seyyedeh Azar [1 ,4 ]
Vander Stappen, Francois [2 ]
Kim, Michele M. [1 ]
Labarbe, Rudi [2 ]
Hotoiu, Lucian [2 ]
Pin, Arnaud [2 ]
Nilsson, Rasmus [3 ]
Traneus, Erik [3 ]
Cengel, Keith A. [1 ]
Zou, Wei [1 ]
Teo, Boon-Keng Kevin [1 ]
Dong, Lei [1 ]
Diffenderfer, Eric S. [1 ]
机构
[1] Univ Penn, Dept Radiat Oncol, 3400 Civ Ctr Blvd,PCAM 2 West, Philadelphia, PA 19104 USA
[2] Ion Beam Applicat SA, IBA, Louvain La Neueve, Belgium
[3] RaySearch Labs AB, Stockholm, Sweden
[4] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI USA
基金
美国国家卫生研究院;
关键词
conformal; flash; log file; monte carlo; proton; QA; IRRADIATION; PBS;
D O I
10.1002/mp.17792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Ultra-high dose rate radiotherapy elicits a biological effect (FLASH), which has been shown to reduce toxicity while maintaining tumor control in preclinical radiobiology experiments. FLASH depends on the dose rate, with evidence that higher dose rates drive increased normal tissue sparing. The pattern of dose delivery also has significance for conformal proton FLASH delivered via pencil beam scanning (PBS) given its unique spatio-temporal distribution of dose deposition. Purpose In PBS, the machine-generated log file contains information on the spatio-temporal pattern of PBS delivery measured by the segmented ionization chambers in the treatment nozzle. The spot position and monitor unit (MU) obtained from log files have previously been used to reconstruct the treatment dose by Monte Carlo (MC) simulations. The incorporation of spot timing allows reconstruction of the 3D temporal dose distribution. The log-based dose and dose rate can have a role in quality assurance (QA) and FLASH treatment verification if the reconstruction can be shown to be accurate in spatial and temporal domains of dose deposition. Thus, the objective of this study is to validate the accuracy of dose rate reconstruction using input data from machine log files of PBS delivery. By analyzing the delivered spot timing, position, and MU extracted from the logs, we aim to evaluate the reliability and precision of the log data for dose and dose rate reconstruction. Methods FLASH PBS spread-out Bragg peak (SOBP) treatment fields were delivered using a cyclotron accelerated proton beam. This method involves a patient and field-specific conformal energy modulator (CEM) to achieve a SOBP at the tumor site. Log files record spot positions and the delivered MU with timing information at 250 mu s resolution. To validate timing information, a 9.9 mm diameter parallel plate ionization chamber was positioned at various locations within the SOBP. An electrometer sampling at 20 kHz recorded the time-resolved ionization current collected by the ionization chamber. These measurements were used to determine spot dose, dose rate, duration, and transition times. Disparities between the measured and logged spot map MU and timing were determined. Dose average and PBS dose rates were compared between the measurement and log-based MC simulations. Results There was a good agreement between the measured dwell time and transition time and the logged information across various detector positions. The median disparities for inter-spot dwell time range from -0.041 to 0.024 ms. Differences between logged and planned spot positions are minimal, measuring less than 1.08 mm in the x direction and 1.15 mm in the y direction, consistent with prior studies and the spatial resolution of the PBS nozzle ionization chamber. Delivered MU were within 1.9% of the planned MU. Measured dose and dose rates are consistent with simulated outcomes derived from MC simulation. Conclusion We validated the precision and accuracy of PBS log file data through measurements and MC simulations. These findings support the use of log files in MC calculations as one part of patient-specific quality assurance (PSQA) and dose rate delivery verification for conformal proton FLASH radiotherapy with SOBP.
引用
收藏
页数:12
相关论文
共 52 条
  • [1] A comprehensive and efficient daily quality assurance for PBS proton therapy
    Actis, O.
    Meer, D.
    Koenig, S.
    Weber, D. C.
    Mayor, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05) : 1661 - 1675
  • [2] [Anonymous], 2000, At Energy, DOI [DOI 10.1097/00004032-200111000-00017, 10.61092/iaea.ve7q-y94k, DOI 10.61092/IAEA.VE7Q-Y94K]
  • [3] [Anonymous], openFLASH GitHub
  • [4] [Anonymous], OpenREGGUI
  • [5] FLASH ultra-high dose rates in radiotherapy: preclinical and radiobiological evidence
    Borghini, Andrea
    Vecoli, Cecilia
    Labate, Luca
    Panetta, Daniele
    Andreassi, Maria Grazia
    Gizzi, Leonida A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2022, 98 (02) : 127 - 135
  • [6] Ultra-fast, high spatial resolution single-pulse scintillation imaging of synchrocyclotron pencil beam scanning proton delivery
    Clark, Megan
    Ding, Xuanfeng
    Zhao, Lewei
    Pogue, Brian
    Gladstone, David
    Rahman, Mahbubur
    Zhang, Rongxiao
    Bruza, Petr
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04)
  • [7] Voxel-wise dose rate calculation in clinical pencil beam scanning proton therapy
    Daartz, Juliane
    Madden, Thomas M.
    Lalonde, Arthur
    Cascio, Ethan
    Verburg, Joost
    Shih, Helen
    MacDonald, Shannon
    Hachadorian, Rachael
    Schuemann, Jan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06)
  • [8] Spread-out Bragg peak proton FLASH irradiation using a clinical synchrocyclotron: Proof of concept and ion chamber characterization
    Darafsheh, Arash
    Hao, Yao
    Zhao, Xiandong
    Zwart, Townsend
    Wagner, Miles
    Evans, Tucker
    Reynoso, Francisco
    Zhao, Tianyu
    [J]. MEDICAL PHYSICS, 2021, : 4472 - 4484
  • [9] Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study
    Deffet, Sylvain
    Hamaide, Valentin
    Sterpin, Edmond
    [J]. MEDICAL PHYSICS, 2023, 50 (09) : 5784 - 5792
  • [10] FLASH Radiotherapy With Electrons: Issues Related to the Production, Monitoring, and Dosimetric Characterization of the Beam
    Di Martino, Fabio
    Barca, Patrizio
    Barone, Salvatore
    Bortoli, Eleonora
    Borgheresi, Rita
    De Stefano, Silvia
    Di Francesco, Massimo
    Faillace, Luigi
    Giuliano, Lucia
    Grasso, Luigi
    Linsalata, Stefania
    Marfisi, Daniela
    Migliorati, Mauro
    Pacitti, Matteo
    Palumbo, Luigi
    Felici, Giuseppe
    [J]. FRONTIERS IN PHYSICS, 2020, 8