Design of a Multi-Parameter Fusion Sensor and System for Respiratory Monitoring of Mechanically Ventilated Patients in the ICU

被引:0
|
作者
Ren, Shuai [1 ]
Wang, Xiaohan [1 ]
Cai, Maolin [2 ]
Shi, Yan [2 ]
Wang, Tao [1 ]
Luo, Zujin [3 ]
机构
[1] Beijing Inst Technol, Sch Automat, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
[3] Capital Med Univ Beijing, Beijing Chao Yang Hosp, Beijing Engn Res Ctr Resp & Crit Care Med, Beijing Inst Resp Med,Dept Resp & Crit Care Med, Beijing 100191, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
Monitoring; Temperature measurement; Temperature sensors; Biomedical monitoring; Ventilators; Ventilation; Real-time systems; Medical services; Humidity; Humidity measurement; Mechanical ventilation; respiratory monitoring; multi-parameter; wireless; remote monitoring; HUMIDITY; TEMPERATURE;
D O I
10.1109/JBHI.2024.3471822
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to achieve precise respiratory therapy for mechanically ventilated patients, real-time monitoring of the state parameters of inhaled and exhaled gases is required. These parameters are primarily measured by ventilators, with limitations such as insufficient monitoring parameters, circuit leaks, and constraints imposed by distance and obstacles. This paper designs a low-power wireless sensor for multi-parameter monitoring near the patient, which can be used continuously for approximately 60 days. Based on this sensor, an intelligent respiratory monitoring system with a distributed architecture is proposed to achieve intelligent patient-ventilator asynchrony (PVA) perception. Experimental results show that the system can stably and accurately collect and transmit data, with measurement errors for pressure, flow, temperature, humidity, and CO (2) concentration being +/- 1.3%, +/- 2.1%, +/- 0.6 degrees C, +/- 1% RH, +/- 0.3 mmHg respectively. The proposed sensor and system have the potential to enhance the efficiency and intelligence of medical care significantly.
引用
收藏
页码:923 / 934
页数:12
相关论文
共 50 条
  • [21] Data fusion in multi-parameter measurement of optical fiber sensors system
    Jiang, JF
    Liu, TG
    Zhang, Y
    Jie, S
    Li, CA
    Sheng, D
    APPLICATIONS OF PHOTONIC TECHNOLOGY 6: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2003, 5260 : 516 - 518
  • [22] Real-Time PVC Recognition System Design Based on Multi-Parameter SE-ResNet
    Li, Duan
    Liu, Peisen
    Sun, Tingting
    Li, Lianxiang
    Xue, Yibai
    IEEE ACCESS, 2024, 12 : 70345 - 70356
  • [23] Study of the Multi-parameter Measuring System Based on Wireless Sensor Network
    Liu Xingqiao
    Li Chengchun
    Zhang Xiangmei
    Liu Yang
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL I, 2009, : 148 - 151
  • [24] Prevalence and prognosis of respiratory pendelluft phenomenon in mechanically ventilated ICU patients with acute respiratory failure: a retrospective cohort study
    Chi, Yi
    Zhao, Zhanqi
    Frerichs, Inez
    Long, Yun
    He, Huaiwu
    ANNALS OF INTENSIVE CARE, 2022, 12 (01)
  • [25] Design of multi-parameter real-time monitoring signal acquisition and analysis system for industrial sewage
    Fu Qi-feng
    Yang Ya-lei
    2014 SEVENTH INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND DESIGN (ISCID 2014), VOL 2, 2014,
  • [26] Prevalence and prognosis of respiratory pendelluft phenomenon in mechanically ventilated ICU patients with acute respiratory failure: a retrospective cohort study
    Yi Chi
    Zhanqi Zhao
    Inéz Frerichs
    Yun Long
    Huaiwu He
    Annals of Intensive Care, 12
  • [27] An appraisal of respiratory system compliance in mechanically ventilated covid-19 patients
    Gianluigi Li Bassi
    Jacky Y. Suen
    Heidi J. Dalton
    Nicole White
    Sally Shrapnel
    Jonathon P. Fanning
    Benoit Liquet
    Samuel Hinton
    Aapeli Vuorinen
    Gareth Booth
    Jonathan E. Millar
    Simon Forsyth
    Mauro Panigada
    John Laffey
    Daniel Brodie
    Eddy Fan
    Antoni Torres
    Davide Chiumello
    Amanda Corley
    Alyaa Elhazmi
    Carol Hodgson
    Shingo Ichiba
    Carlos Luna
    Srinivas Murthy
    Alistair Nichol
    Pauline Yeung Ng
    Mark Ogino
    Antonio Pesenti
    Huynh Trung Trieu
    John F. Fraser
    Critical Care, 25
  • [28] An appraisal of respiratory system compliance in mechanically ventilated covid-19 patients
    Li Bassi, Gianluigi
    Suen, Jacky Y.
    Dalton, Heidi J.
    White, Nicole
    Shrapnel, Sally
    Fanning, Jonathon P.
    Liquet, Benoit
    Hinton, Samuel
    Vuorinen, Aapeli
    Booth, Gareth
    Millar, Jonathan E.
    Forsyth, Simon
    Panigada, Mauro
    Laffey, John
    Brodie, Daniel
    Fan, Eddy
    Torres, Antoni
    Chiumello, Davide
    Corley, Amanda
    Elhazmi, Alyaa
    Hodgson, Carol
    Ichiba, Shingo
    Luna, Carlos
    Murthy, Srinivas
    Nichol, Alistair
    Ng, Pauline Yeung
    Ogino, Mark
    Pesenti, Antonio
    Huynh Trung Trieu
    Fraser, John F.
    CRITICAL CARE, 2021, 25 (01)
  • [29] Design and implementation of multi-parameter portable biological information measurement system
    Zhao Jinchuang
    Zhang Hao
    Fu Wenli
    Zou Xingxing
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 3762 - 3765
  • [30] A multi-parameter signal monitoring system based on Cortex-M3
    Wang, Luyan
    Chen, Hang
    Ye, Shuming
    2014 IEEE WORKSHOP ON ELECTRONICS, COMPUTER AND APPLICATIONS, 2014, : 870 - 873