A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula

被引:2
作者
Mcneely, Richard N. [1 ]
Mcginnity, Katherine [2 ]
Stewart, Stephen [1 ]
Pazo, Emmanuel Eric [3 ,4 ]
Moutari, Salissou [5 ]
Moore, Jonathan E. [1 ,3 ,4 ,6 ]
机构
[1] Cathedral Eye Clin, Belfast BT1 2LS, North Ireland
[2] Belfast Hlth & Social Care Trust, Dept Ophthalmol, Belfast BT12, North Ireland
[3] Tianjin Med Univ, Eye Inst, Tianjin Branch Natl Clin Res Ctr Ocular Dis, Tianjin Key Lab Retinal Funct & Dis,Eye Hosp, Tianjin 300384, Peoples R China
[4] Tianjin Med Univ, Sch Optometry, Eye Hosp, Tianjin 300384, Peoples R China
[5] Queens Univ Belfast, Math Sci Res Ctr, Sch Math & Phys, Belfast BT7 1NN, North Ireland
[6] Aston Univ, Coll Hlth & Life Sci, Birmingham B4 7ET, England
关键词
MM; Barrett; EVO; AS-OCT ray tracing; POWER CALCULATION; REFRACTIVE OUTCOMES; AXIAL LENGTH; ACCURACY;
D O I
10.3390/vision8030049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy). Mean (MAE) and median (MedAE) absolute errors and percentage of eyes within +/- 0.25D, +/- 0.50D, +/- 0.75D, and +/- 1.00D of the target were compared, with +/- 0.75D considered a key metric. The highest percentage within +/- 0.75D was found with MM (96%) followed by the Haigis (94%) for the enhanced monofocal IOL. SRK/T (94%) had the highest percentage within +/- 0.75D, followed by Holladay 1, MM, BUII, and ray tracing (all 90%) for the multifocal IOL. No statistically significant difference in MAE was found with both IOLs. EVO showed the lowest MAE for the enhanced monofocal and ray tracing for the multifocal IOL. EVO and ray tracing showed the lowest MedAE for the two respective IOLs. A similar performance with high accuracy across formulae was found. MM and ray tracing appear to have similar accuracy to the well-established formulae and displayed a high percentage of eyes within +/- 0.75D.
引用
收藏
页数:10
相关论文
共 32 条
[2]   Comparison of the accuracy of 11 intraocular lens power calculation formulas [J].
Carmona-Gonzalez, David ;
Castillo-Gomez, Alfredo ;
Palomino-Bautista, Carlos ;
Romero-Dominguez, Marta ;
Gutierrez-Moreno, Maria Angeles .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) :2370-2376
[3]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[4]   Benchmark standards for refractive outcomes after NHS cataract surgery [J].
Gale, R. P. ;
Saldana, M. ;
Johnston, R. L. ;
Zuberbuhler, B. ;
McKibbin, M. .
EYE, 2009, 23 (01) :149-152
[5]   The estimation of approximate sample size requirements necessary for clinical and epidemiological studies in vision sciences [J].
Goodall, E. A. ;
Moore, J. ;
Moore, T. .
EYE, 2009, 23 (07) :1589-1597
[6]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773
[7]   VRF-G, a New Intraocular Lens Power Calculation Formula: A 13-Formulas Comparison Study [J].
Hipolito-Fernandes, Diogo ;
Luis, Maria Elisa ;
Gil, Pedro ;
Maduro, Vitor ;
Feijao, Joao ;
Yeo, Tun Kuan ;
Voytsekhivskyy, Oleksiy ;
Alves, Nuno .
CLINICAL OPHTHALMOLOGY, 2020, 14 :4395-4402
[9]   Review and recommendations for univariate statistical analysis of spherical equivalent prediction error for IOL power calculations [J].
Holladay, Jack T. ;
Wilcox, Rand R. ;
Koch, Douglas D. ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01) :65-77
[10]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24