Aerosol Delivery Challenges and Strategies for Pediatric Asthma

被引:0
作者
Berlinski, Ariel [1 ,2 ]
机构
[1] Univ Arkansas Med Sci, Coll Med, Dept Pediat, 1 Childrens Way,Slot 512-17, Little Rock, AR 72202 USA
[2] Arkansas Childrens Res Inst, Pediat Aerosol Res Lab, Little Rock, AR USA
关键词
nebulizer; metered dose inhaler; valved holding chamber; inhalation technique; aerosol; pediatrics; dry power inhaler; soft mist inhaler; asthma; METERED-DOSE-INHALER; FLOW NASAL CANNULA; INTERMITTENT NEBULIZED ALBUTEROL; RANDOMIZED CONTROLLED-TRIAL; BREATH-ACTUATED NEBULIZER; SOFT MIST(TM) INHALER; LUNG DEPOSITION; TIDAL VOLUME; FACE MASK; IN-VITRO;
D O I
10.1089/respcare.12626
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Asthma is a chronic respiratory condition affecting 6.5% of the pediatric population in the United States. Inhaled medications are the mainstay of treatment of asthma. Delivering inhaled medications to children with asthma has several challenges. Personalized device selection and education are paramount for successful asthma treatment. The complexity of drug delivery in pediatric asthma is potentiated by the anatomical, physiological, and behavioral differences present in children. In addition, aerosols are given for preventive and for rescue reasons. The latter might also occur in children receiving respiratory support. This article reviews patient- and device-related factors affecting inhaled drug delivery and deposition. It also provides a framework to understand variations of drug delivery that occur during transition between different respiratory support devices. This review also discusses clinical trial data comparing different devices. Finally, guidance on how to choose the right delivery device for each patient is provided.
引用
收藏
页码:721 / 734
页数:14
相关论文
共 98 条
[1]   Improving efficiency of pediatric emergency asthma treatment by using metered dose inhaler [J].
Abaya, Ruth ;
Delgado, Eva M. ;
Scarfone, Richard J. ;
Reardon, Ann Marie ;
Rodio, Bonnie ;
Simpkins, Denise ;
Mehta, Vaidehi ;
Hayes, Katie ;
Zorc, Joseph J. .
JOURNAL OF ASTHMA, 2019, 56 (10) :1079-1086
[2]   Feasibility of Aerosol Bronchodilators Delivery Through High-Flow Nasal Cannula in Pediatric Subjects With Respiratory Distress [J].
Al-Subu, Awni M. ;
Nguyen, Vu T. ;
AlAli, Yousef ;
Yngsdal-Krenz, Rhonda A. ;
Lasarev, Michael R. ;
Eldridge, Marlowe W. ;
Hagen, Scott A. .
RESPIRATORY CARE, 2020, 65 (10) :1464-1469
[3]   Impact of Gas Flow and Humidity on Trans-Nasal Aerosol Deposition via Nasal Cannula in Adults: A Randomized Cross-Over Study [J].
Alcoforado, Luciana ;
Ari, Arzu ;
Barcelar, Jacqueline de Melo ;
Brandao, Simone Cristina S. ;
Fink, James B. ;
de Andrade, Armele Dornelas .
PHARMACEUTICS, 2019, 11 (07)
[4]   Factors that affect the efficacy of inhaled corticosteroids for infants and young children [J].
Amirav, Israel ;
Newhouse, Michael T. ;
Minocchieri, Stefan ;
Castro-Rodriguez, Jose A. ;
Schueepp, Karen G. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2010, 125 (06) :1206-1211
[5]   Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children [J].
Anhoj, J ;
Bisgaard, H ;
Lipworth, BJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1999, 47 (03) :333-336
[6]  
Anhoj J, 2000, AM J RESP CRIT CARE, V162, P1819
[7]  
[Anonymous], 2022, GINA Main Report - Global Initiative for Asthma - GINA
[8]   Longitudinal Evaluation of Compressor/Nebulizer Performance [J].
Awad, Samah ;
Williams, David K. ;
Berlinski, Ariel .
RESPIRATORY CARE, 2014, 59 (07) :1053-1061
[9]   Effect of aerosol delivery system and formulation on nebulized budesonide output [J].
Berlinski, A ;
Waldrep, JC .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1997, 10 (04) :307-318
[10]   Four hours of Continuous albuterol nebulization [J].
Berlinski, A ;
Waldrep, JC .
CHEST, 1998, 114 (03) :847-853