High spatial resolution collinear chiral sum-frequency generation microscopy

被引:0
|
作者
Ji, Ziheng [1 ,2 ]
Yu, Wentao [2 ,3 ]
Dong, Dashan [2 ,4 ]
Yang, Hong [2 ,4 ,5 ]
Liu, Kaihui [2 ]
Xiao, Yun-Feng [2 ,4 ,5 ]
Gong, Qihuang [2 ,4 ,5 ]
Song, Qinghai [1 ,4 ]
Shi, Kebin [2 ,4 ,5 ]
机构
[1] Harbin Inst Technol Shenzhen, Sch Sci, Minist Ind & Informat Technol, Key Lab Micronano Optoelect Informat Syst, Shenzhen, Peoples R China
[2] Peking Univ, Sch Phys, State Key Lab Mesoscop Phys & Frontiers Sci Ctr N, Beijing, Peoples R China
[3] Nanjing Univ Sci & Technol, Inst Interdisciplinary Phys Sci, Sch Sci, Nanjing, Peoples R China
[4] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan, Peoples R China
[5] Peking Univ, Yangtze Delta Inst Optoelect, Nantong, Peoples R China
来源
ADVANCED PHOTONICS NEXUS | 2024年 / 3卷 / 02期
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
chiral sum-frequency generation; radially polarized beam; nonlinear optical microscopy; VIBRATIONAL SPECTROSCOPY; LIQUIDS;
D O I
10.1117/1.APN.3.2.026006
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Chiral sum-frequency generation (SFG) has proven to be a versatile spectroscopic and imaging tool for probing chirality. However, due to polarization restriction, the conventional chiral SFG microscopes have mostly adopted noncollinear beam configurations, which only partially cover the aperture of microscope and strongly spoil the spatial resolution. In this study, we report the first experimental demonstration of collinear chiral SFG microscopy, which fundamentally supports diffraction-limited resolution. This advancement is attributed to the collinear focus of a radially polarized vectorial beam and a linearly polarized (LP) beam. The tightly focused vectorial beam has a very strong longitudinal component, which interacts with the LP beam and produces the chiral SFG. The collinear configuration can utilize the full aperture and thus push the spatial resolution close to the diffraction limit. This technique can potentially boost the understanding of chiral systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Collinear Chiral Sum Frequency Generation Microscopy by Using Vectorial Beam
    Ji, Ziheng
    Yu, Wentao
    Cai, Yanhui
    Yang, Hong
    Liu, Kaihui
    Gong, Qihuang
    Liu, Zhiwen
    Shi, Kebin
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2017,
  • [2] The chiral specificity of sum-frequency generation in solutions
    Fischer, P
    Beckwitt, K
    Wise, FW
    Albrecht, AC
    CHEMICAL PHYSICS LETTERS, 2002, 352 (5-6) : 463 - 468
  • [3] Resonant sum-frequency generation in chiral liquids
    Belkin, MA
    Kulakov, TA
    Ernst, KH
    Han, SH
    Shen, YR
    OPTICAL MATERIALS, 2003, 21 (1-3) : 1 - 5
  • [4] Sum-frequency generation in chiral liquids.
    Kulakov, TA
    Belkin, MA
    Yan, L
    Ernst, KH
    Shen, YR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U344 - U345
  • [5] Molecular Imaging with Sum-frequency Generation Microscopy
    Han, Yang
    Hsu, Julie
    Ge, Nien-Hui
    Potma, Eric O.
    2015 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2015,
  • [6] Ultrafast control over chiral sum-frequency generation
    Vogwell, Joshua
    Rego, Laura
    Smirnova, Olga
    Ayuso, David
    SCIENCE ADVANCES, 2023, 9 (33)
  • [8] Sum-frequency generation studies of chiral adsorbates.
    Messmer, MC
    Pizzolatto, RL
    Yang, YJ
    Wolf, LK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U432 - U432
  • [9] High-resolution sum-frequency generation from alkylsiloxane monolayers
    B.C. Chow
    T.T. Ehler
    T.E. Furtak
    Applied Physics B, 2002, 74 : 395 - 399
  • [10] High-resolution sum-frequency generation from alkylsiloxane monolayers
    Chow, BC
    Ehler, TT
    Furtak, TE
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 74 (4-5): : 395 - 399