Highly Sensitive Non-Enzymatic Electrochemical Sensor to Detect an Important Neurotransmitter Using Cobalt-Based Metal-Organic Framework/Graphene Oxide Composite

被引:0
作者
Houshmand, Shiva [1 ]
Mazloum-Ardakani, Mohammad [1 ]
Mohammadian-Sarcheshmeh, Hamideh [1 ]
Mohseni-Sardari, Fereshteh [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd, Iran
关键词
Neurotransmitter; glutamate; electrochemical sensor; DPV; cobalt-based metal-organic framework; GLASSY-CARBON ELECTRODE; GRAPHENE OXIDE; GLUTAMIC-ACID; NANOCOMPOSITE; PERFORMANCE; ARRAY; IMMOBILIZATION; NANOPARTICLES; EPINEPHRINE; DOPAMINE;
D O I
10.1149/1945-7111/ada57e
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Glutamate (Glu) is a principal neurotransmitter owing to its significant function in physiological and pathological processes. Deviations in Glu levels have been associated with the onset of various neurological disorders, implicating it as a potential biomarker for conditions like epilepsy, stroke, Alzheimer's disease, and amyotrophic lateral sclerosis. Accurate detection of Glu is essential for the prevention, diagnosis, and treatment of such diseases. Herein, a highly sensitive non-enzymatic sensor is introduced to detect Glu. The electrochemical performance of Glu was studied by modifying the glassy carbon electrode using a cobalt-based metal-organic framework/graphene oxide composite (CoMG/GCE). Differential pulse voltammetry exhibited a linear response from 20.0 to 1.00 x 103 mu M at an alkali solution with a detection limit of 3.10 mu M. DPV was utilized to determine Glu in human blood serum samples using the standard addition method. This sensor showed the lowest interference with popular interference species, indicating its ability for healthcare applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide
    Wu, Geng-huang
    Song, Xin-hong
    Wu, Yan-fan
    Chen, Xiao-mei
    Luo, Feng
    Chen, Xi
    TALANTA, 2013, 105 : 379 - 385
  • [22] Non-Enzymatic Electrochemical Sensing of Bisphenol A in Drinking Water and Milk Using Bimetallic Nickel-Copper Metal-Organic Framework
    Dey, Baban
    Ahmad, Md. Wasi
    Al-Shannaq, Refat
    Al-Humaidi, Jehan Y.
    Hossain, S. K. Safdar
    Patra, Chandra N.
    Althomali, Raed H.
    Rahman, Mohammed M.
    Choudhury, Arup
    JOURNAL OF ANALYSIS AND TESTING, 2024, 8 (04) : 451 - 465
  • [23] Non-enzymatic electrochemical sensor for nitrite based on a graphene oxide-polyaniline-Au nanoparticles nanocomposite
    Chen, Guozhen
    Zheng, Jianbin
    MICROCHEMICAL JOURNAL, 2021, 164
  • [24] A CuNi/C Nanosheet Array Based on a Metal-Organic Framework Derivate as a Supersensitive Non-Enzymatic Glucose Sensor
    Zhang, Li
    Ye, Chen
    Li, Xu
    Ding, Yaru
    Liang, Hongbo
    Zhao, Guangyu
    Wang, Yan
    NANO-MICRO LETTERS, 2018, 10 (02)
  • [25] A simple and fast epinephrine voltammetry sensor using reduced graphene oxide and iron metal-organic framework
    Joghani, Roghaiyeh Asadpour
    Rafati, Amir Abbas
    Ghodsi, Javad
    Asl, Azam Zolfaghari
    Feizollahi, Azizallah
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2023, 27 (12) : 3347 - 3361
  • [26] A sensitive non-enzymatic electrochemical glucose sensor based on a ZnO/Co3O4/reduced graphene oxide nanocomposite
    Hussein, Beshir A.
    Tsegaye, Abebaw A.
    Shifera, Getabalew
    M. Taddesse, Abi
    SENSORS & DIAGNOSTICS, 2023, 2 (02): : 347 - 360
  • [27] Construction of a Non-Enzymatic Electrochemical Sensor Based on Metal-Organic-Framework-Derived Manganese Oxide Microspheres for the Detection of Hydrogen Peroxide
    Liu, Xiaohong
    Luo, Caixiu
    Wu, Jinsheng
    He, Nan
    Yu, Rong
    Liu, Xiuhui
    CHEMELECTROCHEM, 2021, 8 (21) : 4141 - 4147
  • [28] Sensitive Non-Enzymatic Glucose Electrochemical Sensor Based on Electrochemically Synthesized PANI/Bimetallic Oxide Composite
    Khan, Anish
    Khan, Aftab Aslam Parwaz
    Marwani, Hadi M.
    Alotaibi, Maha Moteb
    Asiri, Abdullah M.
    Manikandan, Ayyar
    Siengchin, Suchart
    Rangappa, Sanjay Mavinkere
    POLYMERS, 2022, 14 (15)
  • [29] Highly sensitive non-enzymatic MP sensor based on electrospun copper oxide-doped zirconium oxide composite microfibers
    Li, Ling
    Wang, Zhihui
    Wang, Tingting
    Gong, Jian
    Qi, Bin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 846
  • [30] A nanohybrid based on porphyrin dye functionalized graphene oxide for the application in non-enzymatic electrochemical sensor
    Wu, Hai
    Li, Xiang
    Chen, Miaomiao
    Wang, Chang
    Wei, Ting
    Zhang, Hong
    Fan, Suhua
    ELECTROCHIMICA ACTA, 2018, 259 : 355 - 364