Solid-phase extraction combined with dispersive liquid-liquid microextraction for the analysis of glucocorticoids in environmental waters using liquid chromatography-tandem mass spectrometry

被引:0
作者
Antonelli, Lorenzo [1 ]
Dal Bosco, Chiara [1 ]
De Cesaris, Massimo Giuseppe [1 ]
Felli, Nina [1 ]
Lucci, Elena [1 ]
Gentili, Alessandra [1 ]
机构
[1] Sapienza Univ, Dept Chem, Ple Aldo Moro 5, I-00185 Rome, Italy
来源
JOURNAL OF CHROMATOGRAPHY OPEN | 2023年 / 4卷
关键词
Glucocorticoids; Corticosteroids; Deep eutectic solvents; Dispersive liquid-liquid microextraction; Environmental water; HORMONES; IMPACTS; AGENTS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper illustrates an enrichment procedure based on the combination of solid phase extraction (SPE) with dispersive liquid-liquid microextraction (DLLME) for the determination of ng/L concentration levels of glucocorticoids in river water samples. In SPE-DLLME, the target analytes were adsorbed by loading a large volume sample (200 mL) into an OASIS HLB cartridge (60 mg). After their desorption with a small volume of ethyl acetate (500 mu L), this eluate was used as the dispersant in the following DLLME, performed on 5 mL of water, using a low transition temperature mixture (LTTM) as the extractant (100 mu L). The LTTM was obtained by the heat-mixing of choline chloride and sesamol in a molar ratio 1:3 (ChCl:Ses, 1:3); when cooled, it was liquid at room temperature, denser than water and immiscible with it. The SPE-DLLME approach significantly limits the use of high volumes of organic solvents, avoids the evaporation step, and allows one to achieve an enrichment factor greater than 2500. All extracts were analysed by high-performance liquid chromatography-electrospray-tandem mass spectrometry. Eleven glucocorticoids, including the epimers dexamethasone/betamethasone, were separated on a polysaccharide-based column, based on cellulose tris(3-chloro-4-methylphenylcarbamate) chiral selector. Recoveries ranged from 68 to 100% (spike level of 5 and 20 ng/L), with a LOD of 0.21-1.39 ng/L and a LOQ of 0.69-4.17 ng/L. The intra-day precision and inter-day precision were lower than 15%. After optimization and complete validation, the method was applied to analyze surface water samples, taken from River Tiber, to evaluate the effective applicability of the procedure and to establish the contamination levels for these substances.
引用
收藏
页数:8
相关论文
共 34 条
[1]   Residue analysis of glucocorticoids in bovine milk by liquid chromatography-tandem mass spectrometry [J].
Caretti, Fulvia ;
Gentili, Alessandra ;
Ambrosi, Annalisa ;
Rocca, Lucia Mainero ;
Delfini, Maurizio ;
Di Cocco, Maria Enrica ;
D'Ascenzo, Giuseppe .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) :2477-2490
[2]   Pharmaceuticals and personal care products in the environment: Agents of subtle change? [J].
Daughton, CG ;
Ternes, TA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :907-938
[3]   Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of nine corticosteroid residues in bovine liver samples [J].
Dusi, Guglielmo ;
Gasparini, Mara ;
Curatolo, Michele ;
Assini, Walter ;
Bozzoni, Eros ;
Tognoli, Nadia ;
Ferretti, Enrica .
ANALYTICA CHIMICA ACTA, 2011, 700 (1-2) :49-57
[4]   Deep eutectic solvent as a novel disperser in dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFOD) for preconcentration of steroids in water samples: Assessment of the method deleterious impact on the environment using Analytical Eco-Scale and Green Analytical Procedure Index [J].
El-Deen, Asmaa Kamal ;
Shimizu, Kuniyoshi .
MICROCHEMICAL JOURNAL, 2019, 149
[5]   Solid-phase extraction combined with dispersive liquid-liquid microextraction-ultra preconcentration of chlorophenols in aqueous samples [J].
Fattahi, Nazir ;
Samadi, Soheila ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1169 (1-2) :63-69
[6]   Storage of Hydrogen, Methane, and Carbon Dioxide in Highly Porous Covalent Organic Frameworks for Clean Energy Applications [J].
Furukawa, Hiroyasu ;
Yaghi, Omar M. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (25) :8875-8883
[7]   Application of a Low Transition Temperature Mixture for the Dispersive Liquid-Liquid Microextraction of Illicit Drugs from Urine Samples [J].
Gallo, Valeria ;
Tomai, Pierpaolo ;
Di Lisio, Valerio ;
Dal Bosco, Chiara ;
D'Angelo, Paola ;
Fanali, Chiara ;
D'Orazio, Giovanni ;
Silvestro, Ilaria ;
Pico, Yolanda ;
Gentili, Alessandra .
MOLECULES, 2021, 26 (17)
[8]   Dispersive liquid-liquid microextraction using a low transition temperature mixture and liquid chromatography-mass spectrometry analysis of pesticides in urine samples [J].
Gallo, Valeria ;
Tomai, Pierpaolo ;
Gherardi, Monica ;
Fanali, Chiara ;
De Gara, Laura ;
D'Orazio, Giovanni ;
Gentili, Alessandra .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1642
[9]   Chromatographic Methods for the Determination of Emerging Contaminants in Natural Water and Wastewater Samples: A Review [J].
Garcia-Corcoles, M. T. ;
Rodriguez-Gomez, R. ;
de Alarcon-Gomez, B. ;
Cipa, M. ;
Martin-Pozo, L. ;
Kauffmann, J. -M. ;
Zafra-Gomez, A. .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2019, 49 (02) :160-186
[10]   Sodium dodecyl sulfate-multi-walled carbon nanotubes-coated-membrane solid phase extraction of glucocorticoids in aqueous matrices [J].
Goh, Shalene Xue Lin ;
Goh, Esther Xue Yi ;
Lee, Hian Kee .
TALANTA, 2021, 221