High-Frequency Ultrasound for Detecting Periodontal Inflammation: A Preclinical Diagnostic Accuracy Study

被引:1
作者
Samal, Ankita [1 ]
Majzoub, Jad [2 ]
Betancourt, Amanda Rodriguez [3 ]
Webber, Liana [2 ]
Mazzocco, John [2 ]
Wang, Hom-Lay [2 ]
Castilho, Rogerio [2 ]
Fenno, J. Christopher [4 ]
Chan, Hsun-Liang [5 ]
Kripfgans, Oliver D. [6 ]
机构
[1] Univ Iowa, Coll Dent & Dent Clin, Dept Periodontol, Iowa City, IA USA
[2] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[3] Univ Illinois, Coll Dent, Dept Periodontol, Chicago, IL USA
[4] Univ Michigan, Sch Dent, Dept Biol & Mat Sci & Prosthodont, Ann Arbor, MI USA
[5] Ohio State Univ, Coll Dent, Div Periodontol, Columbus, OH 43210 USA
[6] Univ Michigan, Dept Radiol, Ann Arbor, MI USA
基金
美国国家卫生研究院;
关键词
anatomy; periodontal dimension; periodontal phenotype; periodontium; ultrasonography; COMPUTED-TOMOGRAPHY; AESTHETIC ZONE; BONE; ULTRASONOGRAPHY; STABILITY; THICKNESS; BIOTYPE;
D O I
10.1111/jre.13376
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria. Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks. Before euthanization, the periodontium was imaged with US. After euthanization, cone-beam computed tomography (CBCT) scans and histology were performed. Soft and hard tissue measurements by calibrated and masked examiners from US, CBCT, and histology were statistically compared. Results: Seventy-one histological samples with corresponding CBCT and US scans were available for analysis. Overall, there was a good to excellent agreement between histology and US (ICC: 0.77-0.96) for parameters such as Soft Tissue Thickness (STT), Gingival Recession, Crestal Bone Thickness (CBT), and the bone-to-cemento-enamel junction (B-CEJ) distance. However, discrepancies were observed for STT at 3 mm below the CEJ and Soft Tissue Height (STH) (ICC: 0.44 and 0.54, respectively). CBCT showed lower agreement with histology, particularly for thin CBT (< 1 mm), with an ICC of 0.20, compared to 0.90 for US vs. histology. CBCT failed to identify crestal bone in 14 cases when the crestal bone was thin. Notably, CBCT results differed more from histological measurements than US in assessing B-CEJ and thin CBT. Conclusion: US demonstrated substantial potential as a transformative tool for periodontal diagnostics, exhibiting high agreement with histology in determining critical parameters. Compared to CBCT, US offered advantages, particularly in cases with thin crestal bone.
引用
收藏
页数:11
相关论文
共 62 条
[11]  
Carovac Aladin, 2011, Acta Inform Med, V19, P168, DOI 10.5455/aim.2011.19.168-171
[12]   Ultrasonography for diagnosis of peri-implant diseases and conditions: a detailed scanning protocol and case demonstration [J].
Chan, Hsun-Liang ;
Kripfgans, Oliver D. .
DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (07)
[13]   Ridge Alterations Post-extraction in the Esthetic Zone: A 3D Analysis with CBCT [J].
Chappuis, V. ;
Engel, O. ;
Reyes, M. ;
Shahim, K. ;
Nolte, L. -P. ;
Buser, D. .
JOURNAL OF DENTAL RESEARCH, 2013, 92 (S12) :195S-201S
[14]   The utility of 40 MHz periodontal ultrasonography in the assessment of gingival inflammation evolution following professional teeth cleaning [J].
Chifor, Radu ;
Badea, Mindra Eugenia ;
Vesa, Stefan Cristian ;
Chifor, Ioana .
MEDICAL ULTRASONOGRAPHY, 2015, 17 (01) :34-38
[15]  
Chifor R, 2011, MED ULTRASON, V13, P120
[16]   Mucogingival conditions in the natural dentition: Narrative review, case definitions, and diagnostic considerations [J].
Cortellini, Pierpaolo ;
Bissada, Nabil F. .
JOURNAL OF PERIODONTOLOGY, 2018, 89 :S204-S213
[17]   Dose estimation for cone-beam computed tomography in image-guided radiation therapy for pelvic cancer using adult mesh-type reference computational phantoms [J].
Cumur, Ceyda ;
Fujibuchi, Toshioh ;
Arakawa, Hiroyuki ;
Hamada, Keisuke .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (02) :203-211
[18]   Dose estimation for cone-beam computed tomography in image-guided radiation therapy using mesh-type reference computational phantoms and assuming head and neck cancer [J].
Cumur, Ceyda ;
Fujibuchi, Toshioh ;
Hamada, Keisuke .
JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
[19]   Shrinkage of skin excision specimens: formalin fixation is not the culprit [J].
Dauendorffer, J. N. ;
Bastuji-Garin, S. ;
Guero, S. ;
Brousse, N. ;
Fraitag, S. .
BRITISH JOURNAL OF DERMATOLOGY, 2009, 160 (04) :810-814
[20]  