Real-time frequency matching circuit for a high sensitivity cMUT-based gas flow sensor

被引:0
|
作者
Pernu, Tapio [1 ]
Saarilahti, Jaakko [1 ]
Sillanpaa, Teuvo [1 ]
机构
[1] VTT Tech Res Ctr Finland, Dept Microelect & Quantum Technol, FI-02150 Espoo, Finland
关键词
Ultrasound flow measurement; CMUT; Frequency matching; MICROMACHINED ULTRASONIC TRANSDUCERS; OXIDE; DESIGN; FILMS;
D O I
10.1016/j.sna.2025.116252
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a comprehensive study on a low-cost, real-time frequency matching circuit for a high sensitivity gas flow sensor based on cMUTs (Capacitive Micromachined Ultrasonic Transducer). The gas flow sensor is designed with a focus on the mechanical resonance of the moving membrane. It measures gas velocity using the differential transit time method. Custom cMUTs with a resonance frequency of 2.44 MHz were designed and fabricated. The fabrication process involves a 7-step lithography process with thin-film surface micromachining technology. The frequency matching circuit, implemented around a microcontroller, uses conductance measurement and bias voltage sweeping to match resonance frequencies of two cMUTs to the excitation frequency. The flow sensor was tested over a full-scale range with air flow of +/- 50 standard cubic centimeters per minute (sccm), showing a maximum flow error within 0.8 % of the full-scale (FS), demonstrating the state-of-theart sensitivity of cMUT-based gas flow sensors in the literature. The real-time frequency matching circuit significantly reduces zero-flow drift over a temperature range of 0-50 degrees C, from 1.3 % FS to 0.3 % FS. The sensor offers high accuracy and low-cost advantages for ultrasound-based gas flow measurement applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A CMUT-based Real-time Volumetric Ultrasound Imaging System with Row-Column Addressing
    Chen, Albert I. H.
    Wong, Lawrence L.
    Logan, Andrew S.
    Yeow, John T. W.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1755 - 1758
  • [2] Real-Time Coded Excitation Imaging Using a CMUT-Based Side Looking Array for Intravascular Ultrasound
    Zangabad, Reza Pakdaman
    Bosch, Johan G.
    Mastik, Frits
    Beurskens, Robert H. S. H.
    Henneken, Vincent A.
    Weekamp, Johannes W.
    van der Steen, Antonius F. W.
    van Soest, Gijs
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (06) : 2048 - 2058
  • [3] CMUT-based resonant gas sensor array for VOC detection with low operating voltage
    Park, Sangjun
    Yoon, Inug
    Lee, Sungwoo
    Kim, Hyojung
    Seo, Ji-Won
    Chung, Yoonyoung
    Unger, Alexander
    Kupnik, Mario
    Lee, Hyunjoo J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1556 - 1563
  • [4] A High Sensitivity CMUT-Based Passive Cavitation Detector for Monitoring Microbubble Dynamics During Focused Ultrasound Interventions
    Zangabad, Reza Pakdaman
    Lee, Hohyun
    Zhang, Xitie
    Kilinc, M. Sait
    Arvanitis, Costas D.
    Degertekin, F. Levent
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (09) : 1087 - 1096
  • [5] Development of PMUT-Based High Sensitivity Gas Flow Sensor
    Pernu, Tapio
    Sillanpaa, Teuvo
    Karuthedath, Cyril Baby
    Sebastian, Abhilash Thanniyil
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2024, 33 (01) : 88 - 94
  • [6] RF Circuit Implementation of a Real-Time Frequency Spread Emulator
    Karabacak, Murat
    Mohammed, Ahmed Hossam
    Ozdemir, Mehmet Kemal
    Arslan, Huseyin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (01) : 241 - 243
  • [7] Contactless Electrical Sensor Based on Resonance Frequency for Real-Time Monitoring of Bacterial Growth
    Haab, Charles A.
    Jaime, Adriano M.
    Silva, Jussiane S.
    Silva, Thaiane M.
    Pinto, Vandre S.
    Barin, Juliano S.
    Menezes, Cristiano R.
    Viegas, Julio
    Michels, Leandro
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 9326 - 9333
  • [8] Real-Time Correction of Gas Concentration in Nondispersive Infrared Sensor
    Qiang, Zhenfeng
    Wang, Xue
    Zhang, Weihang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [9] Graphene-Based Gas Sensors with High Sensitivity and Minimal Sensor-to-Sensor Variation
    Choi, Jae Hong
    Lee, Junghyun
    Byeon, Mirang
    Hong, Tae Eun
    Park, Hyesung
    Lee, Chang Young
    ACS APPLIED NANO MATERIALS, 2020, 3 (03) : 2257 - 2265
  • [10] A fully printed sensor with optical readout for real-time flow monitoring
    Barmpakos, Dimitris
    Apostolakis, Apostolos
    Pilatis, Aggelos
    Pagonis, Dimitrios-Nikolaos
    Kaltsas, Grigoris
    FLEXIBLE AND PRINTED ELECTRONICS, 2023, 8 (04):