4DCT image artifact detection using deep learning

被引:1
作者
Carrizales, Joshua W. [1 ]
Flakus, Mattison J. [2 ]
Fairbourn, Dallin [3 ]
Shao, Wei [4 ]
Gerard, Sarah E. [1 ]
Bayouth, John E. [5 ]
Christensen, Gary E. [6 ]
Reinhardt, Joseph M. [1 ]
机构
[1] Univ Iowa, Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Wisconsin Madison, Med Phys, Madison, WI USA
[3] Utah State Univ, Biol Engn, Logan, UT USA
[4] Univ Florida, Med, Gainesville, FL USA
[5] Oregon Hlth & Sci Univ, Radiat Med, Portland, OR USA
[6] Univ Iowa, Elect & Comp Engn, Iowa City, IA USA
基金
美国国家卫生研究院;
关键词
deep learning; 4DCT; motion artifacts; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; RESPIRATORY MOTION; TEXTURE ANALYSIS; LUNG; RADIOTHERAPY; REDUCTION; IDENTIFICATION; STATISTICS;
D O I
10.1002/mp.17513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundFour-dimensional computed tomography (4DCT) is an es sential tool in radiation therapy. However, the 4D acquisition process may cause motion artifacts which can obscure anatomy and distort functional measurements from CT scans.PurposeWe describe a deep learning algorithm to identify the location of artifacts within 4DCT images. Our method is flexible enough to handle different types of artifacts, including duplication, misalignment, truncation, and interpolation.MethodsWe trained and validated a U-net convolutional neural network artifact detection model on more than 23 000 coronal slices extracted from 98 4DCT scans. The receiver operating characteristic (ROC) curve and precision-recall curve were used to evaluate the model's performance at identifying artifacts compared to a manually identified ground truth. The model was adjusted so that the sensitivity in identifying artifacts was equivalent to that of a human observer, as measured by computing the average ratio of artifact volume to lung volume in a given scan.ResultsThe model achieved a sensitivity, specificity, and precision of 0.78, 0.99, and 0.58, respectively. The ROC area-under-the-curve (AUC) was 0.99 and the precision-recall AUC was 0.73. Our model sensitivity is 8% higher than previously reported state-of-the-art artifact detection methods.ConclusionsThe model developed in this study is versatile, designed to handle duplication, misalignment, truncation, and interpolation artifacts within a single image, unlike earlier models that were designed for a single artifact type.
引用
收藏
页码:1096 / 1107
页数:12
相关论文
共 50 条
[41]   Target localization accuracy in a respiratory phantom using BrainLab ExacTrac and 4DCT imaging [J].
Matney, Jason E. ;
Parker, Brent C. ;
Neck, Daniel W. ;
Henkelmann, Greg ;
Rosen, Isaac I. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02) :301-309
[42]   4DCT ventilation function image-based functional lung protection for esophageal cancer radiotherapy [J].
Zhou, Pixiao ;
Wang, Ruihao ;
Yu, Hui ;
Liao, Zhiwei ;
Zhang, Ying ;
Huang, Zouqin ;
Zhang, Shuxu .
STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (05) :445-455
[43]   Fake Image Detection Using Deep Learning [J].
Khudeyer R.S. ;
Al-Moosawi N.M. .
Informatica (Slovenia), 2023, 47 (07) :115-120
[44]   Automatic large quantity landmark pairs detection in 4DCT lung images [J].
Fu, Yabo ;
Wu, Xue ;
Thomas, Allan M. ;
Li, Harold H. ;
Yang, Deshan .
MEDICAL PHYSICS, 2019, 46 (10) :4490-4501
[45]   An approach to generate synthetic 4DCT datasets to benchmark Mid-Position implementations [J].
Ghareeb, Firass ;
Boukerroui, Djamal ;
Stroom, Joep ;
Jackson, Edward ;
Pereira, Mariana ;
Gooding, Mark ;
Greco, Carlo .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
[46]   Dosimetric impact of 4DCT artifact in carbon-ion scanning beam treatment: Worst case analysis in lung and liver treatments [J].
Mori, Shinichiro ;
Kumagai, Motoki ;
Karube, Masataka ;
Yamamoto, Naoyoshi .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (06) :787-794
[47]   A review of automatic lung tumour segmentation in the era of 4DCT [J].
Yuzhen, Nadine Wong ;
Barrett, Sarah .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (02) :208-220
[48]   Tissue-Volume Preserving Deformable Image Registration for 4DCT Pulmonary Images [J].
Zhao, Bowen ;
Christensen, Gary E. ;
Song, Joo Hyun ;
Pan, Yue ;
Gerard, Sarah E. ;
Reinhardt, Joseph M. ;
Du, Kaifang ;
Patton, Taylor ;
Bayouth, John M. ;
Hugo, Geoffrey D. .
PROCEEDINGS OF 29TH IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, (CVPRW 2016), 2016, :481-489
[49]   Quantifying ITV instabilities arising from 4DCT: a simulation study using patient data [J].
St James, Sara ;
Mishra, Pankaj ;
Hacker, Fred ;
Berbeco, Ross I. ;
Lewis, John H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :L1-L7
[50]   Commissioning evaluation of a deviceless 4DCT scanner [J].
Tillery, Hunter ;
Windsor, Cheyann ;
Aguilera, Christopher .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (05)