Comparison of biodegradable and metallic tension-band fixation for paediatric lateral condyle fracture of the elbow

被引:1
作者
Kassai, Tamas [1 ]
Krupa, Zsofia [1 ]
Jozsa, Gergo [2 ]
Hanna, Daniel [3 ]
Varga, Marcell [1 ]
机构
[1] Manninger Jeno, Dept Pediat Trauma Surg, Baleseti Kozpont, Budapest, Hungary
[2] Univ Pecs, Sch Med, Div Paediat Surg Traumatol Urol & Paediat Otolary, Dept Paediat, Pecs, Hungary
[3] Univ Pecs, Med Sch Pecsi Tudomanyegyet, Pecs, Hungary
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2024年 / 55卷
关键词
Biodegradable implants; Paediatric elbow; Lateral condyle fracture; Tension-band fixation; Fracture; Bioresorbable; FOREIGN-BODY REACTION; BIOABSORBABLE FIXATION; FOREARM FRACTURES; IMPLANTS; HUMERUS; SURGERY;
D O I
10.1016/j.injury.2024.111403
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: In our retrospective study we compared the outcomes of paediatric lateral condyle fractures of the elbow fixed by bioabsorbable pins and tension-band sutures or by metallic tension-band with K-wires. Materials and methods: We reviewed the data of children operated on for lateral condyle fractures between 2010 and 2020. Patients were classified as follows: 1. fractures treated with metallic (KW group), 2. fractures treated with resorbable implants (BR group). We compared the distribution of age, sex and fracture type in each group. Operative times of the two techniques were also recorded and compared. We analysed the X-rays taken one year after the injury and measured the following parameters: presence of possible non-union, varus or valgus deviation, lateral spur formation. Patients whose follow-up period was less than one year were excluded. For categorical data, group comparisons were performed with Chi-square test or Fisher's exact test, depending on the sample size. The evaluation of discrete variables was performed with Mann-Whitney U test. Results: 42 patients met the above criteria. We found 19 children in the Kirschner -wire + tansion band wire (KW) group and 23 in the Bioresorbable pin + tension band suture (BR) group. There were no significant differences between the study groups in terms of age, sex, left-right ratio, number of complications, operation time, number of Jacobs II and III cases or follow-up time. The operation time was on average 5 min longer in the bioresorbable group (K-wire mean = 62.1 min, Bioresorbable mean = 67 min), this difference, however, is not statistically significant (P = 0.177). In terms of minor and major complications, there was no statistically significant difference between the two groups. (P = 0.729). Conclusions: We did not notice any difference between the complication rates of the two methods, so the real advantage of the absorbable implant technique is that no second intervention is necessary. The benefits of using biodegradable implants in various osteosynthesis techniques need further confirmation by randomised trials.
引用
收藏
页数:7
相关论文
共 31 条
  • [1] Radiologic, clinical, and functional evaluation of children with lateral humeral condyle fractures using the Quick Disabilities of the Arm, Shoulder, and Hand questionnaire
    Abusaq, Ibrahim
    Martins, Antoine
    Mansour, Mounira
    Samba, Antoine
    Dimeglio, Alain
    Canavese, Federico
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2023, 32 (02): : 121 - 126
  • [2] Current Concepts in the Treatment of Lateral Condyle Fractures in Children
    Abzug, Joshua M.
    Dua, Karan
    Kozin, Scott H.
    Herman, Martin J.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (01) : E9 - E19
  • [3] Lateral Condyle Fracture of the Humerus in Children Treated with Bioabsorbable Materials
    Andrey, Veronique
    Tercier, Stephane
    Vauclair, Frederic
    Bregou-Bourgeois, Aline
    Lutz, Nicolas
    Zambelli, Pierre-Yves
    [J]. SCIENTIFIC WORLD JOURNAL, 2013,
  • [4] FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS
    BOSTMAN, O
    HIRVENSALO, E
    MAKINEN, J
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04): : 592 - 596
  • [5] Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
  • [6] Protein delivery from poly(lactic-co-glycolic acid) biodegradable microspheres: release kinetics and stability issues
    Crotts, G
    Park, TG
    [J]. JOURNAL OF MICROENCAPSULATION, 1998, 15 (06) : 699 - 713
  • [7] K-wire Versus Screw Fixation in Displaced Lateral Condyle Fractures of the Humerus in Children: A Multicenter Study of 762 Fractures
    Cummings, Jason L.
    Schwabe, Maria T.
    Rivera, Asdrubal E.
    Sanders, Julia
    Denning, Jaime R.
    Neal, Kevin
    Bellaire, Laura L.
    Choe, Josh
    Gaio, Natalie
    Goldstein, Rachel
    Crowe, Mary
    Hosseinzadeh, Pooya
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2023, 43 (04) : E284 - E289
  • [8] Preliminary experience with biodegradable implants for fracture fixation
    Dhillon, Mandeep S.
    Prabhakar, Sharad
    Prasanna, Chandiralingam
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2008, 42 (03) : 319 - 322
  • [9] Lateral condylar fractures of the humerus in children DOES THE TYPE OF FIXATION MATTER?
    Ganeshalingam, R.
    Donnan, A.
    Evans, O.
    Hoq, M.
    Camp, M.
    Donnan, L.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (03) : 387 - 395
  • [10] Delayed Foreign-body Reaction to Absorbable Implants in Metacarpal Fracture Treatment
    Givissis, Panagiotis K.
    Stavridis, Stavros I.
    Papagelopoulos, Panayiotis J.
    Antonarakos, Petros D.
    Christodoulou, Anastasios G.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (12) : 3377 - 3383