Diagnostic accuracy of reduced electroencephalography montages for seizure detection: A frequentist and Bayesian meta-analysis

被引:1
作者
Lin, Yu-Chen [1 ]
Lin, Hui-An [2 ,3 ,4 ]
Chang, Ming-Long [2 ,4 ]
Lin, Sheng-Feng [3 ,4 ,5 ,6 ,7 ]
机构
[1] Taipei Med Univ, Coll Med, Sch Med, Taipei, Taiwan
[2] Taipei Med Univ, Coll Med, Sch Med, Dept Emergency Med, Taipei, Taiwan
[3] Taipei Med Univ, Coll Publ Hlth, Sch Publ Hlth, Taipei, Taiwan
[4] Taipei Med Univ Hosp, Dept Emergency Med, Taipei, Taiwan
[5] Taipei Med Univ, Coll Med, Sch Med, Dept Publ Hlth, Taipei, Taiwan
[6] Taipei Med Univ, Ctr Evidence Based Med, Taipei, Taiwan
[7] Taipei Med Univ Hosp, Dept Med Res, Taipei, Taiwan
来源
NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY | 2025年 / 55卷 / 02期
关键词
Electroencephalography (EEG); Meta-analysis; Reduced EEG montage; Seizure; Subhairline EEG; SYSTEMATIC REVIEWS; ELECTRODE ARRAYS; EEG MONTAGE; SENSITIVITY; MANAGEMENT;
D O I
10.1016/j.neucli.2025.103044
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aim: To evaluate the diagnostic accuracy of reduced montage electroencephalography (EEG) for seizure detection and provide evidence-based recommendations. Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we conducted a diagnostic meta-analysis to assess the sensitivity and specificity of reduced EEG montages in detecting seizure activity. A hierarchical summary receiver operating characteristic curve (HSROC) model was used to estimate the area under the curve (AUC). Subgroup analyses were conducted to identify sources of heterogeneity. Bayesian estimates were used for validation. Results: Across 8 studies encompassing 3,458 reduced EEG montage samples, all studies used a reduced EEG montage with 7 to 10 electrodes. The pooled sensitivity was 0.75 (95 % CI: 0.68-0.80), and the pooled specificity was 0.97 (95 % CI: 0.95-0.98). The HSROC model had an AUC of 0.96 (95 % CI: 0.93-0.97). Variations in study results were attributed to factors such as the number of electrodes (pooled sensitivity of 0.66 for studies employing <8 leads and 0.77 for studies employing >= 8 leads) and montage design coverage (pooled sensitivity of 0.64 for studies employing subhairline montage and 0.77 for studies employing above-hairline montage). The Bayesian and frequentist findings agreed with each other and had a pooled sensitivity of 0.74 (95 % HPD: 0.65-0.83) and pooled specificity of 0.97 (95 % highest posterior density 0.95-0.98). Conclusion: Reduced EEG montages with 8 or more electrodes are feasible for seizure detection, especially in emergency settings where rapid detection is crucial.
引用
收藏
页数:7
相关论文
共 26 条
  • [1] Overview of EEG Montages and Principles of Localization
    Acharya, Jayant N.
    Acharya, Vinita J.
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2019, 36 (05) : 325 - 329
  • [2] Bernabei John M, 2021, Crit Care Explor, V3, pe0476, DOI 10.1097/CCE.0000000000000476
  • [3] Guidelines for the Evaluation and Management of Status Epilepticus
    Brophy, Gretchen M.
    Bell, Rodney
    Claassen, Jan
    Alldredge, Brian
    Bleck, Thomas P.
    Glauser, Tracy
    LaRoche, Suzette M.
    Riviello, James J., Jr.
    Shutter, Lori
    Sperling, Michael R.
    Treiman, David M.
    Vespa, Paul M.
    [J]. NEUROCRITICAL CARE, 2012, 17 (01) : 3 - 23
  • [4] The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    Deeks, JJ
    Macaskill, P
    Irwig, L
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) : 882 - 893
  • [5] Midline and Parasagittal Seizures are Rare in Adult Patients
    Gururangan, Kapil
    Parvizi, Josef
    [J]. NEUROCRITICAL CARE, 2020, 32 (01) : 193 - 197
  • [6] Diagnostic utility of eight-channel EEG for detecting generalized or hemispheric seizures and rhythmic periodic patterns
    Gururangan, Kapil
    Razavi, Babak
    Parvizi, Josef
    [J]. CLINICAL NEUROPHYSIOLOGY PRACTICE, 2018, 3 : 65 - 73
  • [7] Meta-analysis for diagnostic tests
    Hartzes, Anastasia M.
    Morgan, Charity J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 68 - 71
  • [8] Reduced electrode arrays for the automated detection of rhythmic and periodic patterns in the intensive care unit: Frequently tried, frequently failed?
    Herta, J.
    Koren, J.
    Fuerbass, F.
    Hartmann, M.
    Gruber, A.
    Baumgartner, C.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2017, 128 (08) : 1524 - 1531
  • [9] Measuring inconsistency in meta-analyses
    Higgins, JPT
    Thompson, SG
    Deeks, JJ
    Altman, DG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414): : 557 - 560
  • [10] Jasper H., 1958, ELECTROEN CLIN NEURO, V10, P370, DOI [10.1016/0013-4694(58)90053-1, DOI 10.1016/0013-4694(58)90053-1]