Effectiveness of low-intensity pulsed ultrasound in patients after osteotomy: A systematic review

被引:0
作者
Caamano, J. Rama [1 ]
Sousa, O. Iglesias [2 ]
机构
[1] Clin Med REHASALUD, La Coruna, Spain
[2] Complejo Hosp Univ A Coruna, La Coruna, Spain
来源
REHABILITACION | 2024年 / 58卷 / 02期
关键词
LIPUS; Low intensity pulsed ultrasound; Ultrasound therapy; Osteotomy; Bone consolidation; DELAYED-UNION; LIPUS;
D O I
10.1016/j.rh.2023.100826
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The use of low intensity pulsed ultrasound (LIPUS) therapy for bone healing and fracture treatment is increasingly considered as a therapeutic alternative with moderate economic cost and none or minimal adverse effects (e.g., low reaction to the conductive gel). However, there is some controversy regarding its scientific evidence. The present review seeks to shed some light on this controversy and to cover an area of study not occupied by previous or current work on ultrasound therapy. It is necessary to know the real impact of the treatment with low intensity pulsed ultrasound in patients with osteotomy, as well as its applicability as a post-surgery protocol to improve the recovery and rehabilitation processes and, at the end of the day, to reduce the time of disability. (c) 2023 Sociedad Espanola de Rehabilitacion y Medicina F & imath;sica. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页数:9
相关论文
共 33 条
[1]  
[Anonymous], 2012, Newcastle-Ottawa quality assessment form for cohort studies
[2]   Effect of low-intensity pulsed ultrasound after intraoral vertical ramus osteotomy [J].
Arimoto, Satomi ;
Hasegawa, Takumi ;
Takeda, Daisuke ;
Tateishi, Chizu ;
Akashi, Masaya ;
Furudoi, Shungo ;
Komori, Takahide .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 128 (06) :581-589
[3]  
Cano SMA, 2002, Rev Mex Med Fis Rehab, V14, P26
[4]  
Chingonton RB, 2001, Reemo, V10, P3
[5]   Introduction to critical reading of articles: Study design and biases [J].
Garcia Villar, C. .
RADIOLOGIA, 2015, 57 :3-13
[6]  
Goshima Kenichi, 2017, J Orthop Trauma, V31, pS3, DOI 10.1097/01.bot.0000520894.00094.cb
[7]   Mode & mechanism of low intensity pulsed ultrasound (LIPUS) in fracture repair [J].
Harrison, Andrew ;
Lin, Sheldon ;
Pounder, Neill ;
Mikuni-Takagaki, Yuko .
ULTRASONICS, 2016, 70 :45-52
[8]   ACCELERATION OF TIBIAL FRACTURE-HEALING BY NONINVASIVE, LOW-INTENSITY PULSED ULTRASOUND [J].
HECKMAN, JD ;
RYABY, JP ;
MCCABE, J ;
FREY, JJ ;
KILCOYNE, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) :26-34
[9]   CONVINCING EVIDENCE FROM CONTROLLED AND UNCONTROLLED STUDIES ON THE LIPID-LOWERING EFFECT OF A STATIN [J].
Higgins, Julian .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (12)
[10]  
King-Martinez Ana Cristina, 2007, Rev Med Inst Mex Seguro Soc, V45, P111