Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling

被引:1
作者
Marsala, Richard [1 ,2 ]
Dvorak, Milos [1 ]
Kuban, Pavel [1 ]
机构
[1] Czech Acad Sci, Inst Analyt Chem, Veveri 97, CZ-60200 Brno, Czech Republic
[2] Masaryk Univ, Fac Sci, Dept Chem, Kamenice 5, CZ-62500 Brno, Czech Republic
来源
ADVANCES IN SAMPLE PREPARATION | 2025年 / 13卷
关键词
Automation; Capillary electrophoresis; Contactless conductivity detection; Dried blood spot; Lactate; Volumetric absorptive microsampling; QUANTITATIVE BIOANALYSIS; ASSAY BIAS; LACTATE; CHROMATOGRAPHY; HEMATOCRIT; URINE;
D O I
10.1016/j.sampre.2024.100142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated method for the analysis of dried blood samples collected by volumetric absorptive microsampling (VAMS) is presented for the first time. A single commercial capillary electrophoresis (CE) instrument (with no need for hardware or software modifications) was employed for the expeditious analyses of the dried material using several integral and novel features. These included the use of external pressure for sub-minute sample preparation from Mitra (R) VAMS polymeric tips, the use of the sampling tips as inherent micro-agitators for instant eluate homogenization, preparation/sampling at the CE outlet for more convenient capillary length adjustment, and short-end injection for sub-minute CE separation and quantification of lactate as a model analyte. The operational parameters for the sample preparation and analysis were comprehensively evaluated resulting in a baseline separation of lactate from all endogenous matrix compounds. The optimized method demonstrated excellent intra- and inter-day repeatability of peak areas (RSD values <= 7.2 %), linearity (R2 = 0.9990) over the clinically relevant concentration range (0.15 - 20 mM), the limits of detection and quantification at 0.03 and 0.1 mM, respectively, and a sample throughput >= 16 samples/hour. No ageing was observed for VAMS devices stored at ambient conditions for up to 14 days. Comparative analysis with a portable lactate analyser revealed slightly elevated concentrations in dried vs. liquid capillary blood due to the glycolysis of glucose during drying, nevertheless, lactate concentrations in Mitra (R) devices correlated well with those in blood plasma, which is typically used in clinical practice. The present study offers a robust, accurate, and environmentally benign concept for the automated analyses of VAMS-collected blood samples with its potential application in patient-centric sampling, clinical diagnostics and research, and personalized healthcare.
引用
收藏
页数:9
相关论文
共 51 条
[1]   Cost-effectiveness analysis of repeated self-sampling for HPV testing in primary cervical screening: a randomized study [J].
Aarnio, Riina ;
Ostensson, Ellinor ;
Olovsson, Matts ;
Gustavsson, Inger ;
Gyllensten, Ulf .
BMC CANCER, 2020, 20 (01)
[2]  
[Anonymous], About us
[3]   Rapid determination of phenylalanine and tyrosine in volumetrically collected dried blood spots using fully automated processing and analysis by capillary electrophoresis [J].
Aranda-Merino, Noemi ;
Dvorak, Milos ;
Kuban, Pavel .
TALANTA, 2025, 284
[4]  
Bonaventura JM, 2015, J SPORT SCI MED, V14, P203
[5]   Volumetric Absorptive Microsampling in the Analysis of Endogenous Metabolites [J].
de Sa e Silva, Daniel Marques ;
Thaitumu, Marlene ;
Theodoridis, Georgios ;
Witting, Michael ;
Gika, Helen .
METABOLITES, 2023, 13 (10)
[6]   Alternative Sampling Devices to Collect Dried Blood Microsamples: State-of-the-Art [J].
Delahaye, Lisa ;
Veenhof, Herman ;
Koch, Birgit C. P. ;
Alffenaar, Jan-Willem C. ;
Linden, Rafael ;
Stove, Christophe .
THERAPEUTIC DRUG MONITORING, 2021, 43 (03) :310-321
[7]   Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis [J].
Denniff, Philip ;
Spooner, Neil .
ANALYTICAL CHEMISTRY, 2014, 86 (16) :8489-8495
[8]   The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs [J].
Denniff, Philip ;
Spooner, Neil .
BIOANALYSIS, 2010, 2 (08) :1385-1395
[9]   Dried blood microsampling-assisted therapeutic drug monitoring of immunosuppressants: An overview [J].
Deprez, Sigrid ;
Stove, Christophe P. .
JOURNAL OF CHROMATOGRAPHY A, 2023, 1689
[10]   Evaluation and clinical implication of lactate measurement by amperometry and spectrophotometry [J].
Diz Mellado, O. M. ;
Melguizo Madrid, E. ;
Saez-Benito Godino, A. .
CLINICA CHIMICA ACTA, 2019, 493 :S13-S14