Temperature dependence compensation of X-ray spectrometry with MiniPIX Timepix3 SiC detector

被引:0
|
作者
Kurucova, N. [1 ]
Granja, C. [2 ]
Hladik, D. [2 ]
Sagatova, A. [1 ]
Zatko, B. [3 ]
机构
[1] Slovak Univ Technol Bratislava, Inst Nucl & Phys Engn, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 84104, Slovakia
[2] ADVACAM, Pergamenky 12, Prague 17000, Czech Republic
[3] Slovak Acad Sci, Inst Elect Engn, Dubravska Cesta 9, Bratislava 84104, Slovakia
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 02期
关键词
Detector design and construction technologies and materials; Radiation-hard detectors; Radiation-hard electronics; X-ray detectors;
D O I
10.1088/1748-0221/20/02/C02033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Timepix3 is a hybrid pixel radiation detector, from the CERN-designed Timepix family, which contains 65.536 pixels. The detectors based on Timepix3 read-out chips have started to be used in a wide range of applications, such as medicine, particle physics, neutron detection and space applications. For applications in harsh environments such as space, particle therapy and nuclear power engineering, silicon carbide (SiC) stands as suitable semiconductor sensor thanks to its chemical stability, wide temperature operation range and enhanced radiation hardness. Newly developed MiniPIX Timepix3 SiC cameras are undergoing physical and operating tests for various applications. Since their main applications are in harsh environments where they are exposed to a wide range of temperatures, it is important to examine and describe the behaviour of these detectors under the influence of different temperatures. Consequently, it is necessary to compensate these temperature effects. Thus, this study investigates the temperature dependence of the spectral (deposited energy) response of the Timepix3 detectors equipped with a 4H-SiC sensor over a temperature range of 10 degrees C to 60 degrees C, with a per-pixel energy calibration performed at 20 degrees C. The detector was exposed to fluorescence X-rays with energies between 8 keU and 58 keU and between 31 keU and 40 keU from the radioactive sources 133Ba and 152Eu, respectively. It was found that with increasing temperature there is a shift of the energy spectra to lower values, which increases with increasing incident energy. A compensation method is proposed to correct for the distortion in the measured energy range.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] X-ray topographic study of SiC crystal at high temperature
    Yamaguchi, H
    Oyanagi, N
    Kato, T
    Takano, Y
    Nishizawa, S
    Bahng, W
    Yoshida, S
    Arai, K
    SILICON CARBIDE AND RELATED MATERIALS - 1999 PTS, 1 & 2, 2000, 338-3 : 461 - 464
  • [43] Detector random time delay compensation method for X-ray pulsar observation
    Zhang, Dapeng
    Zheng, Wei
    Wang, Yidi
    Chen, Yong
    Cui, Weiwei
    Yang, Yanji
    OPTIK, 2017, 149 : 430 - 438
  • [44] Temperature dependence of Al0.2Ga0.8As X-ray photodiodes for X-ray spectroscopy
    Whitaker, M. D. C.
    Butera, S.
    Lioliou, G.
    Barnett, A. M.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (03)
  • [45] ANOMALOUS TEMPERATURE-DEPENDENCE OF X-RAY INTERFERENCE INTENSITY OF BATIO3
    IVANOV, SA
    CHORNEY, SA
    MIKHALCHENKO, VP
    VENEVTSEV, YN
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S315 - S315
  • [46] Temperature dependence of commercial 4H-SiC UV Schottky photodiodes for X-ray detection and spectroscopy
    Zhao, S.
    Lioliou, G.
    Barnett, A. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 859 : 76 - 82
  • [47] Low temperature chemical vapor deposition of 3C-SiC on 6H-SiC - An x-ray triple crystal diffractometry and x-ray topography study
    Chaudhuri, J
    Ignatiev, K
    Edgar, JH
    Xie, ZY
    Gao, Y
    WIDE-BANDGAP SEMICONDUCTORS FOR HIGH POWER, HIGH FREQUENCY AND HIGH TEMPERATURE, 1998, 512 : 169 - 174
  • [48] 3 DIMENSIONAL DIGITAL X-RAY MICROTOMOGRAPHY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    ROCKETT, P
    WEBB, S
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1989, 37 (3-4): : 92 - 97
  • [49] Improvement of the detector resolution in X-ray spectrometry by using the maximum entropy method
    Fernandez, Jorge E.
    Scot, Viviana
    Di Giulio, Eugenio
    Sabbatucci, Lorenzo
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 194 - 198
  • [50] DEPENDENCE OF X-RAY SENSITIVITY OF BACTERIOPHAGE ON PHASE STATE AND TEMPERATURE
    WOOD, TH
    NATURE, 1954, 173 (4405) : 641 - 642