Temperature dependence compensation of X-ray spectrometry with MiniPIX Timepix3 SiC detector

被引:0
|
作者
Kurucova, N. [1 ]
Granja, C. [2 ]
Hladik, D. [2 ]
Sagatova, A. [1 ]
Zatko, B. [3 ]
机构
[1] Slovak Univ Technol Bratislava, Inst Nucl & Phys Engn, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 84104, Slovakia
[2] ADVACAM, Pergamenky 12, Prague 17000, Czech Republic
[3] Slovak Acad Sci, Inst Elect Engn, Dubravska Cesta 9, Bratislava 84104, Slovakia
来源
JOURNAL OF INSTRUMENTATION | 2025年 / 20卷 / 02期
关键词
Detector design and construction technologies and materials; Radiation-hard detectors; Radiation-hard electronics; X-ray detectors;
D O I
10.1088/1748-0221/20/02/C02033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Timepix3 is a hybrid pixel radiation detector, from the CERN-designed Timepix family, which contains 65.536 pixels. The detectors based on Timepix3 read-out chips have started to be used in a wide range of applications, such as medicine, particle physics, neutron detection and space applications. For applications in harsh environments such as space, particle therapy and nuclear power engineering, silicon carbide (SiC) stands as suitable semiconductor sensor thanks to its chemical stability, wide temperature operation range and enhanced radiation hardness. Newly developed MiniPIX Timepix3 SiC cameras are undergoing physical and operating tests for various applications. Since their main applications are in harsh environments where they are exposed to a wide range of temperatures, it is important to examine and describe the behaviour of these detectors under the influence of different temperatures. Consequently, it is necessary to compensate these temperature effects. Thus, this study investigates the temperature dependence of the spectral (deposited energy) response of the Timepix3 detectors equipped with a 4H-SiC sensor over a temperature range of 10 degrees C to 60 degrees C, with a per-pixel energy calibration performed at 20 degrees C. The detector was exposed to fluorescence X-rays with energies between 8 keU and 58 keU and between 31 keU and 40 keU from the radioactive sources 133Ba and 152Eu, respectively. It was found that with increasing temperature there is a shift of the energy spectra to lower values, which increases with increasing incident energy. A compensation method is proposed to correct for the distortion in the measured energy range.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] X-ray micro-CT scanner for small animal imaging based on Timepix detector technology
    Dudak, Jan
    Zemlicka, Jan
    Krejci, Frantisek
    Polansky, Stepan
    Jakubek, Jan
    Mrzilkova, Jana
    Patzelt, Matej
    Trnka, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 773 : 81 - 86
  • [32] Characterization of a Pixelated CdTe X-Ray Detector Using the Timepix Photon-Counting Readout Chip
    Ruat, Marie
    Ponchut, Cyril
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2392 - 2401
  • [33] X-Ray Detector With Internal Gain Based on a SiC npn Structure
    Wang, Jing
    Chen, Liang
    Bai, Song
    Zhou, Leidang
    Wang, Fangbao
    Zhang, Silong
    Fan, Tingting
    Huang, Runhua
    Yang, Shaohua
    Tian, Geng
    Ouyang, Xiaoping
    IEEE ELECTRON DEVICE LETTERS, 2024, 45 (11) : 2142 - 2145
  • [34] TEMPERATURE-DEPENDENCE OF X-RAY DEBYE TEMPERATURE OF INDIUM
    VOLD, CL
    RICHARDS, LE
    REPORT OF NRL PROGRESS, 1975, (MAR): : 35 - 36
  • [35] Temperature dependence of AlGaAs soft X-ray detectors
    Barnett, A. M.
    Bassford, D. J.
    Lees, J. E.
    Ng, J. S.
    Tan, C. H.
    David, J. P. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 453 - 455
  • [36] TEMPERATURE DEPENDENCE OF ANOMALOUS X-RAY TRANSMISSION IN SILICON
    KYUTT, RN
    EFIMOV, ON
    SOVIET PHYSICS SOLID STATE,USSR, 1969, 11 (02): : 228 - +
  • [38] TEMPERATURE-DEPENDENCE OF X-RAY PLASMON SCATTERING
    PRIFTIS, GD
    PHYSICAL REVIEW B, 1973, 8 (07): : 3134 - 3137
  • [39] Gas proportional scintillation detector with a focusing system for X-ray spectrometry
    Vikulov, IV
    Komin, VE
    Shchekin, KI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1996, 39 (02) : 275 - 278
  • [40] Compensation Of X-ray Mirror Distortion By Cooling Temperature Control
    Hand, Matthew
    Wang, Hongchang
    Harkiolaki, Maria
    Venturini, Federica
    Arrigo, Rosa
    Ferrer-Escorihuela, Pilar
    Alcock, Simon
    Nistea, Ioana
    Marshall, Andy
    Scott, Stewart
    Duke, Liz
    Held, Georg
    Sawhney, Kawal
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054