Spectral performance for iodine quantification of a dual-source, dual-kV photon counting detector CT

被引:0
|
作者
Winfree, Tim [1 ]
Treb, Kevin [1 ]
Mccollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 1st St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
adaptive filtration; dual-source CT; iodine quantification; multi-energy CT; photon counting detector CT; ENERGY CT;
D O I
10.1002/mp.17679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMulti-energy CT (MECT) enables quantification of material concentrations by measuring linear attenuation coefficient line integrals with multiple x-ray spectra. Photon counting detector (PCD)-CT utilizes a detector-based approach for MECT that can suffer from substantial spectral overlap, resulting in amplified material quantification noise. Dual-source dual-kV approaches for MECT are currently utilized in some energy-integrating detector (EID)-CT systems and can potentially be utilized with PCD-CT for improved spectral separation.PurposeTo evaluate the iodine quantification performance of a novel dual-source (DS)-PCD-CT scan mode and compare to single-source (SS)-PCD-CT and DS-EID-CT.Materials and MethodsA 30 cm x 40 cm solid water phantom with four iodine inserts (2, 5, 10, and 15 mg/mL) was scanned with the three spectral modalities: SS-PCD-CT with two energy thresholds, DS-PCD-CT (90/Sn150 kV), and DS-EID-CT (90/Sn150 kV). For each modality, full-dose (12 mGy) and half-dose scans were acquired, and images were reconstructed with filtered back-projection using a quantitative (Qr40) kernel. When scanning in a DS configuration, the total radiation dose budget is split between two detectors, increasing the strength of a signal-dependent filter compared to a SS acquisition. To account for this effect, the modulation transfer function (MTF) for each modality was measured from a 0.05 mm tungsten wire. A linear spatial filter was applied to the SS images to match their MTF to that of the DS images. The resulting high- and low-energy images were input into an image-domain least squares material decomposition algorithm with iodine and water as the two basis materials. Iodine quantification accuracy and noise measured from the iodine basis images were used as figures of merit, and t-tests used to compare between modalities.ResultsThe 10% MTF cutoffs were 0.56, 0.57, 0.60, and 0.57 lp/mm for DS-EID-CT, DS-PCD-CT, SS-PCD-CT, and SS-PCD-CT after MTF-matching, respectively, with the SS-PCD-CT MTF cutoff dropping to 0.58 lp/mm at half-dose. Without accounting for the signal-dependent filter by matching the MTFs, the noise in iodine material basis images from SS-PCD-CT was 10% higher than that of DS-EID-CT. After matching the MTFs, the noise in the SS-PCD-CT iodine image was 9%-22% lower than that of the DS-EID-CT. The lowest iodine image noise was from the DS-PCD-CT, which was 39%-41% lower than the DS-EID-CT. The DS-PCD-CT noise magnitude was significantly different from the other modalities. Mean iodine quantification accuracy across all measured concentrations was within 5% for all modalities at full dose, but was only below 5% for the DS-PCD-CT at half-dose.ConclusionsSS-PCD-CT with two energy thresholds outperformed DS-EID-CT in terms of image noise in iodine basis images when spatial resolution was matched. DS-PCD-CT gave the lowest noise due to the combination of PCD technology and improved spectral separation from the different x-ray spectra.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [32] Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT
    Delesalle, Marie-Aurelie
    Pontana, Francois
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Flohr, Thomas
    Tacelli, Nunzia
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2013, 267 (01) : 256 - 266
  • [33] Impact of Photon Counting Detector Spectral Response on Dual Energy Techniques
    Wang, Adam S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [34] Stent imaging on a clinical dual-source photon-counting detector CT system—impact of luminal attenuation and sharp kernels on lumen visibility
    Josua A. Decker
    Jim O’Doherty
    U. Joseph Schoepf
    Thomas M. Todoran
    Gilberto J. Aquino
    Verena Brandt
    Dhiraj Baruah
    Nicola Fink
    Emese Zsarnoczay
    Thomas Flohr
    Bernhard Schmidt
    Thomas Allmendinger
    Franka Risch
    Akos Varga-Szemes
    Tilman Emrich
    European Radiology, 2023, 33 : 2469 - 2477
  • [35] High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT
    Ahmed, Zaki
    Campeau, David
    Gong, Hao
    Rajendran, Kishore
    Rajiah, Prabhakar
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (03) : 1428 - 1435
  • [36] Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT
    Pelgrim, Gert Jan
    van Hamersvelt, Robbert W.
    Willemink, Martin J.
    Schmidt, Bernhard T.
    Flohr, Thomas
    Schilham, Arnold
    Milles, Julien
    Oudkerk, Matthijs
    Leiner, Tim
    Vliegenthart, Rozemarijn
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3904 - 3912
  • [37] Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT
    Gert Jan Pelgrim
    Robbert W. van Hamersvelt
    Martin J. Willemink
    Bernhard T. Schmidt
    Thomas Flohr
    Arnold Schilham
    Julien Milles
    Matthijs Oudkerk
    Tim Leiner
    Rozemarijn Vliegenthart
    European Radiology, 2017, 27 : 3904 - 3912
  • [38] Simultaneous high-pitch multi-energy CT pulmonary angiography using a dual-source photon-counting-detector CT: A phantom experiment
    Mihailovic, Jelena M.
    Bruesewitz, Michael R.
    Swicklik, Joseph R.
    Yalon, Mariana
    Rajiah, Prabhakar S.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (11):
  • [39] Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT
    Kaltenbach, Benjamin
    Wichmann, Julian L.
    Pfeifer, Sophia
    Albrecht, Moritz H.
    Booz, Christian
    Lenga, Lukas
    Hammerstingl, Renate
    Dangelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 20 - 24
  • [40] Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Yoshida, Ryoichi
    Katayama, Takuto
    Arimoto, Makoto
    Kataoka, Jun
    Nagata, Hiroji
    Kobayashi, Satoshi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 143 - 153