Spectral performance for iodine quantification of a dual-source, dual-kV photon counting detector CT

被引:0
|
作者
Winfree, Tim [1 ]
Treb, Kevin [1 ]
Mccollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 1st St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
adaptive filtration; dual-source CT; iodine quantification; multi-energy CT; photon counting detector CT; ENERGY CT;
D O I
10.1002/mp.17679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMulti-energy CT (MECT) enables quantification of material concentrations by measuring linear attenuation coefficient line integrals with multiple x-ray spectra. Photon counting detector (PCD)-CT utilizes a detector-based approach for MECT that can suffer from substantial spectral overlap, resulting in amplified material quantification noise. Dual-source dual-kV approaches for MECT are currently utilized in some energy-integrating detector (EID)-CT systems and can potentially be utilized with PCD-CT for improved spectral separation.PurposeTo evaluate the iodine quantification performance of a novel dual-source (DS)-PCD-CT scan mode and compare to single-source (SS)-PCD-CT and DS-EID-CT.Materials and MethodsA 30 cm x 40 cm solid water phantom with four iodine inserts (2, 5, 10, and 15 mg/mL) was scanned with the three spectral modalities: SS-PCD-CT with two energy thresholds, DS-PCD-CT (90/Sn150 kV), and DS-EID-CT (90/Sn150 kV). For each modality, full-dose (12 mGy) and half-dose scans were acquired, and images were reconstructed with filtered back-projection using a quantitative (Qr40) kernel. When scanning in a DS configuration, the total radiation dose budget is split between two detectors, increasing the strength of a signal-dependent filter compared to a SS acquisition. To account for this effect, the modulation transfer function (MTF) for each modality was measured from a 0.05 mm tungsten wire. A linear spatial filter was applied to the SS images to match their MTF to that of the DS images. The resulting high- and low-energy images were input into an image-domain least squares material decomposition algorithm with iodine and water as the two basis materials. Iodine quantification accuracy and noise measured from the iodine basis images were used as figures of merit, and t-tests used to compare between modalities.ResultsThe 10% MTF cutoffs were 0.56, 0.57, 0.60, and 0.57 lp/mm for DS-EID-CT, DS-PCD-CT, SS-PCD-CT, and SS-PCD-CT after MTF-matching, respectively, with the SS-PCD-CT MTF cutoff dropping to 0.58 lp/mm at half-dose. Without accounting for the signal-dependent filter by matching the MTFs, the noise in iodine material basis images from SS-PCD-CT was 10% higher than that of DS-EID-CT. After matching the MTFs, the noise in the SS-PCD-CT iodine image was 9%-22% lower than that of the DS-EID-CT. The lowest iodine image noise was from the DS-PCD-CT, which was 39%-41% lower than the DS-EID-CT. The DS-PCD-CT noise magnitude was significantly different from the other modalities. Mean iodine quantification accuracy across all measured concentrations was within 5% for all modalities at full dose, but was only below 5% for the DS-PCD-CT at half-dose.ConclusionsSS-PCD-CT with two energy thresholds outperformed DS-EID-CT in terms of image noise in iodine basis images when spatial resolution was matched. DS-PCD-CT gave the lowest noise due to the combination of PCD technology and improved spectral separation from the different x-ray spectra.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance
    Tao, Ashley
    Huang, Richard
    Tao, Shengzhen
    Michalak, Gregory J.
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11)
  • [2] Performance of iodine quantification through high-pitch dual-source photon-counting CT: a phantom study
    Liu, Peng
    Zhou, Shanshui
    Dong, Haipeng
    Li, Jiqiang
    Xu, Zhihan
    Lin, Shushen
    Yang, Wenjie
    Yan, Fuhua
    Qin, Le
    JAPANESE JOURNAL OF RADIOLOGY, 2025, 43 (02) : 309 - 318
  • [3] Quantitative assessment of motion effects in dual-source dual-energy CT and dual-source photon-counting detector CT
    Ahmed, Zaki
    Rajendran, Kishore
    Gong, Hao
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [4] Multi-energy CT imaging for large patients using dual-source photon-counting detector CT
    Tao, Shengzhen
    Marsh, Jeffrey F.
    Tao, Ashley
    Michalak, Greg J.
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
  • [5] Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study
    Tao, Shengzhen
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL PHYSICS, 2019, 46 (09) : 4105 - 4115
  • [6] Consistency of spectral results in cardiac dual-source photon-counting CT
    Liu, Leening P.
    Shapira, Nadav
    Sahbaee, Pooyan
    Gang, Grace J.
    Knollman, Friedrich D.
    Chen, Marcus Y.
    Litt, Harold I.
    Noel, Peter B.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT
    Oechsner, Tim
    Soschynski, Martin
    Schlett, Christopher L.
    Krauss, Tobias
    Schupppert, Christopher
    Mueller-Peltzer, Katharina
    Vecsey-Nagy, Milan
    Kravchenko, Dmitrij
    Varga-Szemes, Akos
    Emrich, Tilman
    Scheu, Raphael
    Taron, Jana
    Bamberg, Fabian
    Hagar, Muhammad Taha
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 183
  • [8] Impact of patient habitus and acquisition protocol on iodine quantification in dual-source photon-counting computed tomography
    Liu, Leening P.
    Pua, Rizza
    Dieckmeyer, Michael
    Shapira, Nadav
    Sahbaee, Pooyan
    Gang, Grace J.
    Litt, Harold I.
    Noel, Peter B.
    JOURNAL OF MEDICAL IMAGING, 2024, 11
  • [9] Multi-Contrast Imaging on Dual-Source Photon-Counting-Detector (PCD) CT
    Tao, Shengzhen
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [10] Performance evaluation of single- and dual-contrast spectral imaging on a photon-counting-detector CT
    Ren, Liqiang
    Zhou, Zhongxing
    Ahmed, Zaki
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2024, 51 (11) : 8034 - 8046