Refrigerants evaluation and energy performance optimization for a high-temperature carbon dioxide plus hydrofluoroolefin / hydrochlorofluoroolefin cascade heat pump dryer with two air heating circuits

被引:0
|
作者
Xu, Yingjie [1 ,2 ]
Jia, Liulu [1 ]
Ye, Yufeng [3 ]
Liu, Jiameng [1 ]
Shen, Xi [1 ]
Han, Xiaohong [4 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Engn Res Ctr Proc Equipment & Remfg, Minist Educ, Hangzhou 310014, Peoples R China
[2] Zhejiang Univ Technol, Taizhou Inst, Taizhou Key Lab Adv Mfg Technol, Taizhou 318014, Peoples R China
[3] Zhejiang Tobacco Co LTD, Hangzhou 310002, Peoples R China
[4] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310018, Peoples R China
关键词
Carbon dioxide heat pump; Heat pump drying system; Environment-friendly refrigerants; High-temperature heat pump; Multi-objective optimization; SYSTEM;
D O I
10.1016/j.enconman.2025.119677
中图分类号
O414.1 [热力学];
学科分类号
摘要
The carbon dioxide heat pump is promising for energy savings and emission reductions in the drying industry due to its good performance. However, the efficiency of carbon dioxide gas cooler is low under drying working condition, due to significant temperature glide of supercritical state. Moreover, for many drying materials, the drying temperature provided by current heat pumps is still lower than the optimal drying temperature. To resolve these issues, a new low-carbon refrigerant + carbon dioxide transcritical cascade heat pump drying system has been proposed. In this new system, the discharged carbon dioxide from the compressor of lowtemperature stage is cooled by both fresh air and the low-carbon refrigerant through two distinct heat exchangers. System simulation and multi-objective optimization are conducted based on experimentally validated model. The results show that when R1234ze(Z) is used at high temperature stage, the system performs the best, with a maximum coefficient of performance of 1.78, heating capacity of 20.2 kW, condensing temperature of 110 degrees C, and low-temperature heat source of 10 degrees C. The best individual in Pareto front is selected, with 3.55 x 104 CNY/year and 3.47 x 104 kg/year. The optimal geometric parameters of components are determined as follows, 3.39 m2 gas-cooler heat transfer area, 48 m2 condensing heat transfer area and 9.68 MPa parameters of heat rejection pressure. Additionally, the impact of critical factors on system performance was investigated. The new system and the results of this paper are expected to provide new ideas for high-temperature heat pump drying system and system energy saving.
引用
收藏
页数:16
相关论文
共 10 条
  • [1] Performance and Economic Analysis of Two Types of High-Temperature Heat Pump Based on New Refrigerants
    Sun, Dahan
    Qin, Jiang
    Liu, Zhongyan
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [2] Theoretical evaluation of energy, exergy, and minimum superheat in a high-temperature heat pump with low GWP refrigerants
    Sulaiman, Adam Y.
    Cotter, Donal
    Arpagaus, Cordin
    Hewitt, Neil
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 99 - 109
  • [3] Energy, exergy, economic and environmental analyses and optimization of a novel vapor injection autocascade heat pump for high-temperature water heating
    Chen, Jiaheng
    Chen, Qi
    Qin, Xiang
    Wang, Dingbiao
    ENERGY CONVERSION AND MANAGEMENT, 2022, 267
  • [4] Performance analysis and multi-objective optimization of the high-temperature cascade heat pump system
    Wu, Zhangxiang
    Wang, Xiaoyan
    Sha, Li
    Li, Xiaoqiong
    Yang, Xiaochen
    Ma, Xuelian
    Zhang, Yufeng
    ENERGY, 2021, 223
  • [5] Transcritical-transcritical cascade CO2 heat pump cycles for high-temperature heating: A numerical evaluation
    Kong, Lana
    Walmsley, Timothy Gordon
    Hoang, Duy Khanh
    Schlosser, Florian
    Chen, Qun
    Carson, James K.
    Cleland, Donald John
    APPLIED THERMAL ENGINEERING, 2024, 238
  • [6] An experimental energy performance investigation and economic analysis on a cascade heat pump for high-temperature water in cold region
    Xu, Liangfeng
    Li, Enteng
    Xu, Yingjie
    Mao, Ning
    Shen, Xi
    Wang, Xinlei
    RENEWABLE ENERGY, 2020, 152 : 674 - 683
  • [7] Life cycle performance evaluation of cascade-heating high temperature heat pump system for waste heat utilization: Energy consumption, emissions and financial analyses
    Dai, Baomin
    Liu, Xiao
    Liu, Shengchun
    Wang, Dabiao
    Meng, Chenyang
    Wang, Qi
    Song, Yifan
    Zou, Tonghua
    ENERGY, 2022, 261
  • [8] Characteristic analysis and performance optimization of a transcritical CO2 heat pump for high-temperature heating: An experimental study
    Yang, Lingxiao
    Wang, Xin
    Xu, Bo
    Chen, Zhenqian
    RENEWABLE ENERGY, 2024, 237
  • [9] Heat exchanger design and performance evaluation for a high-temperature heat pump system under different two-phase correlations: 4E analysis
    Wu, Ding
    Ma, Bo
    Huang, Xiaohui
    Wu, Xian
    Yang, Yan
    Wen, Chuang
    Zhang, Ji
    APPLIED ENERGY, 2025, 384
  • [10] Performance optimization and evaluation of integrating thermochemical energy storage with low-temperature driven absorption heat pump for building heating: 4E analyses
    Wang, Yihan
    Chen, Tingsen
    Liu, Shuli
    Ji, Wenjie
    Shen, Yongliang
    Wang, Zhihao
    Li, Yongliang
    APPLIED ENERGY, 2024, 372