Denoising Improves Cross-Scanner and Cross-Protocol Test-Retest Reproducibility of Diffusion Tensor and Kurtosis Imaging

被引:0
作者
Ades-Aron, Benjamin [1 ,2 ]
Coelho, Santiago [1 ]
Lemberskiy, Gregory [2 ]
Veraart, Jelle [1 ]
Baete, Steven H. [1 ]
Shepherd, Timothy M. [1 ]
Novikov, Dmitry S. [1 ]
Fieremans, Els [1 ]
机构
[1] New York Univ, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York 10012, NY USA
[2] Microstruct Imaging Inc, Brooklyn, NY 11201 USA
基金
美国国家卫生研究院;
关键词
brain white matter; clinical translation; diffusion kurtosis imaging; diffusion tensor imaging; higher-order diffusion; image denoising; MPPCA; test-retest reproducibility; GAUSSIAN WATER DIFFUSION; MRI; TRACT; MICROSTRUCTURE; QUANTIFICATION; ACQUISITION; MOVEMENT;
D O I
10.1002/hbm.70142
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The clinical translation of diffusion magnetic resonance imaging (dMRI)-derived quantitative contrasts hinges on robust reproducibility, minimizing both same-scanner and cross-scanner variability. As multi-site data sets, including multi-shell dMRI, expand in scope, enhancing reproducibility across variable MRI systems and MRI protocols becomes crucial. This study evaluates the reproducibility of diffusion kurtosis imaging (DKI) metrics (beyond conventional diffusion tensor imaging (DTI)), at the voxel and region-of-interest (ROI) levels on magnitude and complex-valued dMRI data, using denoising with and without harmonization. We compared same-scanner, cross-scanner, and cross-protocol variability for a multi-shell dMRI protocol (2-mm isotropic resolution, b = 0, 1000, 2000 s/mm2) in 20 subjects. We first evaluated the effectiveness of Marchenko-Pastur Principal Component Analysis (MPPCA) based denoising strategies for both magnitude and complex data to mitigate noise-induced bias and variance, to improve dMRI parametric maps and reproducibility. Next, we examined the impact of denoising under different population analysis approaches, specifically comparing voxel-wise versus region of interest (ROI)-based methods. We also evaluated the role of denoising when harmonizing dMRI across scanners and protocols. The results indicate that DTI and DKI maps visually improve after MPPCA denoising, with noticeably fewer outliers in kurtosis maps. Denoising, either using magnitude or complex dMRI, enhances voxel-wise reproducibility, with test-retest variability of kurtosis indices reduced from 15%-20% without denoising to 5%-10% after denoising. Complex dMRI denoising reduces the noise floor by up to 60%. Denoising not only reduced variability across scans and protocols, but also increased statistical power for low SNR voxel-wise comparisons when comparing cross sectional groups. In conclusion, MPPCA denoising, either over magnitude or complex dMRI data, enhances the reproducibility and precision of higher-order diffusion metrics across same-scanner, cross-scanner, and cross-protocol assessments. The enhancement in data quality and precision facilitates the broader application and acceptance of these advanced imaging techniques in both clinical practice and large-scale neuroimaging studies.
引用
收藏
页数:20
相关论文
共 90 条
  • [1] Evaluation of the accuracy and precision of the diffusion parameter EStImation with Gibbs and NoisE removal pipeline
    Ades-Aron, Benjamin
    Veraart, Jelle
    Kochunov, Peter
    McGuire, Stephen
    Sherman, Paul
    Kellner, Elias
    Novikov, Dmitry S.
    Fieremans, Els
    [J]. NEUROIMAGE, 2018, 183 : 532 - 543
  • [2] A NEW PHASE CORRECTION METHOD IN NMR IMAGING BASED ON AUTOCORRELATION AND HISTOGRAM ANALYSIS
    AHN, CB
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (01) : 32 - 36
  • [3] Noise estimation in single- and multiple-coil magnetic resonance data based on statistical models
    Aja-Fernandez, Santiago
    Tristan-Vega, Antonio
    Alberola-Lopez, Carlos
    [J]. MAGNETIC RESONANCE IMAGING, 2009, 27 (10) : 1397 - 1409
  • [4] Imaging brain microstructure with diffusion MRI: practicality and applications
    Alexander, Daniel C.
    Dyrby, Tim B.
    Nilsson, Markus
    Zhang, Hui
    [J]. NMR IN BIOMEDICINE, 2019, 32 (04)
  • [5] MODIFIED ITERATIVE MODEL BASED ON DATA EXTRAPOLATION METHOD TO REDUCE GIBBS RINGING
    AMARTUR, S
    HAACKE, EM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03): : 307 - 317
  • [6] Incorporating outlier detection and replacement into a non-parametric framework for movement and distortion correction of diffusion MR images
    Andersson, Jesper L. R.
    Graham, Mark S.
    Zsoldos, Eniko
    Sotiropoulos, Stamatios N.
    [J]. NEUROIMAGE, 2016, 141 : 556 - 572
  • [7] An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging
    Andersson, Jesper L. R.
    Sotiropoulos, Stamatios N.
    [J]. NEUROIMAGE, 2016, 125 : 1063 - 1078
  • [8] Structure-adaptive sparse denoising for diffusion-tensor MRI
    Bao, Lijun
    Robini, Marc
    Liu, Wanyu
    Zhu, Yuemin
    [J]. MEDICAL IMAGE ANALYSIS, 2013, 17 (04) : 442 - 457
  • [9] Basser PJ, 2000, MAGNET RESON MED, V44, P41, DOI 10.1002/1522-2594(200007)44:1<41::AID-MRM8>3.0.CO
  • [10] 2-O