Effectiveness and robustness of using nonlinear pendulum tuned mass damper inerters for wind-induced vibration mitigation of high-rise buildings

被引:0
|
作者
Yang, Xunchen [1 ]
Ma, Ruisheng [1 ,2 ]
Bi, Kaiming [3 ,4 ]
Li, Huan [1 ]
Du, Xiuli [1 ]
机构
[1] Beijing Univ Technol, State Key Lab Bridge Engn Safety & Resilience, Beijing, Peoples R China
[2] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian, Peoples R China
[3] Hong Kong Polytech Univ, Res Ctr Urban Hazards Mitigat RCUHM, Hong Kong, Peoples R China
[4] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Nonlinear pendulum tuned mass damper inerters; Clutched inerter; High-rise building; Optimization design; Control effectiveness; Wind-induced response; Robustness; SEISMIC RESPONSE; OPTIMAL-DESIGN; TURBINE TOWER;
D O I
10.1016/j.istruc.2025.108356
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tall buildings are at risk of experiencing vibrations induced by the wind because of their long fundamental periods and low inherent damping. These excessive vibrations can threaten the structural safety and the comfort of residents. For this reason, pendulum tuned mass dampers (PTMDs) are commonly employed to reduce the adverse vibrations of high-rise buildings. However, their applications are often accompanied by concerns over the large auxiliary mass required and overabundant swing angles. To tackle the above issues, this study investigates the potential of using inerters to enhance the conventional PTMDs for achieving more effective windinduced vibration mitigation performance of high-rise buildings. In particular, the concepts and working mechanisms of two nonlinear pendulum tuned mass damper inerters (NPTMDIs) with different configurations are first presented. Subsequently, the analytical models of a high-rise building equipped with NPTMDIs are established, and the optimal parameters of NPTMDIs are obtained via genetic algorithm by minimizing the maximum top-floor absolute acceleration of the building structure. Ultimately, the vibration control effectiveness of the two NPTMDIs is evaluated and contrasted with that of a conventional PTMD. Moreover, the robustness of NPTMDIs against structure and device parameter variations is also comprehensively evaluated. The results demonstrate that NPTMDIs demonstrate greater effectiveness compared to PTMD in mitigating the wind-induced responses of the high-rise building with much smaller swing angles of the tip mass, and they exhibit better robustness against the mistuning issue induced by the perturbations of structural stiffness and damping. Besides, compared to NPTMDI with configuration II, the vibration control effectiveness and robustness of NPTMDI I are more significant.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
    Giaralis, Agathoklis
    Petrini, Francesco
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (09)
  • [2] THE WIND-INDUCED VIBRATION CONTROL OF HIGH-RISE CHIMNEYS BY A TUNED MASS DAMPER INERTER (TMDI)
    Su N.
    Peng S.-T.
    Hong N.-N.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (11): : 143 - 156
  • [3] Bi-directional wind-induced vibration control of high-rise buildings using bi-directional rail variable friction pendulum-tuned mass damper
    Xiang, Yue
    Tan, Ping
    Wu, Jiurong
    He, Hui
    Shang, Jiying
    Yang, Kui
    Zheng, Zhuopeng
    ENGINEERING STRUCTURES, 2024, 303
  • [4] Wind-induced vibration mitigation of video screen rooms in high-rise buildings
    Rizzo, Fabio
    Ierimonti, Laura
    Venanzi, Ilaria
    Sacconi, Stefano
    STRUCTURES, 2021, 33 : 2388 - 2401
  • [5] ROBUST OPTIMUM DESIGN OF TUNED MASS DAMPERS FOR HIGH-RISE BUILDINGS SUBJECT TO WIND-INDUCED VIBRATION
    Rossato, Bibiana Bertolin
    Fadel Miguel, Letcia Fleck
    NUMERICAL ALGEBRA CONTROL AND OPTIMIZATION, 2023, 13 (01): : 154 - 168
  • [6] Wind-induced vibration of high-rise building with tuned mass damper including soil-structure interaction
    Liu, Ming-Yi
    Chiang, Wei-Ling
    Hwang, Jin-Hung
    Chu, Chia-Ren
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (6-7) : 1092 - 1102
  • [7] Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper
    Aly, Aly Mousaad
    SMART STRUCTURES AND SYSTEMS, 2014, 13 (03) : 473 - 500
  • [8] Asymmetric and Cubic Nonlinear Energy Sink Inerters for Mitigating Wind-Induced Responses of High-Rise Buildings
    Wang, Qinhua
    Wu, Huaxiao
    Qiao, Haoshuai
    Yu, Xianfeng
    Huang, Peng
    STRUCTURAL CONTROL & HEALTH MONITORING, 2023, 2023
  • [9] Experimental parametric study on wind-induced vibration control of particle tuned mass damper on a benchmark high-rise building
    Lu, Zheng
    Wang, Dianchao
    Zhou, Ying
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (08):
  • [10] Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter (vol 143, 2017)
    Giaralis, Agathoklis
    Petrini, Francesco
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)