Total Reflection X-ray Fluorescence Spectrometry: A Comprehensive Review of Critical Components, Analytical Benefits and Practical Applications

被引:1
作者
Zhang, Yongsheng [1 ,2 ]
Yuan, Jian [3 ]
Xu, Tao [4 ]
Dong, Lei [1 ,2 ]
Ma, Weiguang [1 ,2 ]
Zhang, Lei [1 ,2 ]
Yin, Wangbao [1 ,2 ]
Jia, Suotang [1 ,2 ]
机构
[1] Shanxi Univ, Inst Laser Spect, State Key Lab Quantum Opt & Quantum Opt Devices, Taiyuan 030006, Peoples R China
[2] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan, Peoples R China
[3] Beijing Res Inst Uranium Geol, Beijing 100029, Peoples R China
[4] Fujian Normal Univ, Sch Phys & Energy, Fuzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Laboratory-built TXRF; Component optimization; Multi-element analysis; Sample pretreatment; Practical applications; LOW Z-ELEMENTS; TRACE-ELEMENTS; TOXIC ELEMENTS; WAVE-GUIDE; SAMPLES; QUANTIFICATION; PERFORMANCE; MILK; SPECTROSCOPY; METALS;
D O I
10.1080/10408347.2024.2411245
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Total reflection X-ray fluorescence spectrometry (TXRF) is a pivotal technique in modern atomic spectroscopy, distinguished by its capability for multi-element simultaneous determination, a wide dynamic concentration range, samples do not require acid digestion. Additionally, TXRF exhibits negligible matrix effects when samples are prepared as thin films. Based on these unique features, recent research efforts have increasingly employed laboratory-built TXRF systems for the determination of major and trace elements in various samples. Given the diverse and intricate nature of TXRF systems components, this paper provides an overview of critical components that constitute these systems, compares the influence of various parameters on analytical performance, and offers recommendations for component selection. Additionally, recent applications of laboratory-built TXRF in fields such as environmental monitoring, nuclear energy, and food safety are discussed, with a focus on sample preparation, analyzed elements, and quantitative analysis are presented together with analytical parameters such as detection limits and recoveries. By introducing the instrument components and their practical applications, this paper aims to guide researchers in the construction and optimization of TXRF systems, thereby promoting the advancement of TXRF in future research and practical applications.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Total reflection X-ray fluorescence as a tool for food screening
    Borgese, Laura
    Bilo, Fabjola
    Dalipi, Rogerta
    Bontempi, Elza
    Depero, Laura E.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 113 : 1 - 15
  • [22] Quantification of gold nanoparticles in blood using total reflection X-ray fluorescence
    Mankovskii, Gabriella
    Pejovic-Milic, Ana
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 194
  • [23] Atomic spectrometry update - a review of advances in X-ray fluorescence spectrometry and its special applications
    Vanhoof, Christine
    Bacon, Jeffrey R.
    Fittschen, Ursula E. A.
    Vincze, Laszlo
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (09) : 1797 - 1812
  • [24] Determination of Halide Impurities in Ionic Liquids by Total Reflection X-ray Fluorescence Spectrometry
    Vander Hoogerstraete, Tom
    Jamar, Steven
    Wellens, Sil
    Binnemans, Koen
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (08) : 3931 - 3938
  • [25] Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater
    Dhara, Sangita
    Misra, N. L.
    [J]. PRAMANA-JOURNAL OF PHYSICS, 2011, 76 (02): : 361 - 366
  • [26] Application of total reflection X-ray fluorescence spectrometry for multi-elements characterization in human hair
    Yadav, V. B.
    Pillay, R. H.
    Jha, S. K.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (01) : 57 - 60
  • [27] Determination of trace elements in uranium oxide by Total Reflection X-ray Fluorescence spectrometry
    Misra, NL
    Mudher, KDS
    Adya, VC
    Rajeswari, B
    Venugopal, V
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (06) : 834 - 840
  • [28] Trace element quantification in light fuels by total reflection X-ray fluorescence spectrometry
    Cinosi, A.
    Siviero, G.
    Monticelli, D.
    Furian, R.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 164
  • [29] 2020 atomic spectrometry update - a review of advances in X-ray fluorescence spectrometry and its special applications
    Vanhoof, Christine
    Bacon, Jeffrey R.
    Fittschen, Ursula E. A.
    Vincze, Laszlo
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (09) : 1704 - 1719
  • [30] Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry
    Khuder, A.
    Sawan, M. Kh.
    Karjou, J.
    Razouk, A. K.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) : 721 - 725