Comparison of the C-MAC D-Blade Video Laryngoscope and the McCoy Laryngoscope in Difficult Airway Patients According to Arne Multivariate Risk Classification: A Randomised Prospective Trial

被引:0
作者
Duran, M. [1 ]
Yilmaz, N. [1 ]
Tepe, M. [1 ]
Kaya, R. [2 ]
Dogukan, M. [1 ]
Nakir, H. [3 ]
Magac, M. S. [4 ]
机构
[1] Adiyaman Univ, Fac Med, Dept Anesthesiol & Reanimat, Adiyaman, Turkiye
[2] Private Yeni Hayat Hosp, Dept Anesthesiol & Reanimat, Osmaniye, Turkiye
[3] Nazilli State Hosp, Dept Anesthesiol & Reanimat, Aydin, Turkiye
[4] Balikesir State Hosp, Dept Anesthesiol & Reanimat, Balikesir, Turkiye
关键词
C-MAC D-blade video laryngoscope; difficult airway; McCoy laryngoscope; TRACHEAL INTUBATION; MANAGEMENT; BOUGIE;
D O I
10.4103/njcp.njcp_422_24
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Difficult intubation is an important cause of morbidity and mortality during anaesthesia. Detection of patient with difficult airway is very important. Arne multivariate risk classification score is one of the tests that is used to detect this difficult airway patients. McCoy direct laryngoscope and the C-MAC videolaryngoscope are parts of among the tools that are currently used for these patients. Aim:This study aimed to compare the intubation success and access the quality of difficult airway using the McCoy direct laryngoscope and the C-MAC video laryngoscope. Methods:Included in this study were 100 patients scheduled for elective surgery, ASA I-III, who had the Arne multivariate risk classification score >11. The patients were randomly divided into the C-MAC D-Blade video laryngoscope (n = 50) and the McCoy laryngoscope (n = 50). The Mallampati score, Arne multivariate score, intubation success, required time for intubation, number of intubation attempts, required time to visualize the glottis, need for auxiliary equipment, and complications were recorded. Results:No differences in the demographic data were observed between the two groups (P > 0.05). In addition, no differences were observed between the groups in the required time to visualize the glottis (P = 0.801) or the Arne score (P = 0.619). The rate of use of gum elastic bougies in Grup C-MAC was lower (P = 0.014), and the intubation success rate was higher during the first attempt (P = 0.016). The intubation time was longer in the McCoy group (P = 0.017). Conclusion:The C-MAC D-Blade video laryngoscope was superior to the McCoy direct laryngoscope for difficult-to-intubate patients due to the shorter required time for intubation, higher intubation success rate, and lesser need for auxiliary equipment.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 45 条
  • [41] First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population
    Aziz, Michael F.
    Abrons, Ron O.
    Cattano, Davide
    Bayman, Emine O.
    Swanson, David E.
    Hagberg, Carin A.
    Todd, Michael M.
    Brambrink, Ansgar M.
    ANESTHESIA AND ANALGESIA, 2016, 122 (03) : 740 - 750
  • [42] Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices-A Non-Inferiority Trial
    Bacher, Viktor
    Nemeth, Marton
    Rendeki, Szilard
    Tornai, Balazs
    Rozanovic, Martin
    Pankaczi, Andrea
    Olah, Janos
    Farkas, Jozsef
    Chikhi, Melania
    Schlegl, Adam
    Maroti, Peter
    Nagy, Balint
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [43] Comparison of Glidescope Core, C-MAC Miller and conventional Miller laryngoscope for difficult airway management by anesthetists with limited and extensive experience in a simulated Pierre Robin sequence: A randomized crossover manikin study
    Moritz, Andreas
    Holzhauser, Luise
    Fuchte, Tobias
    Kremer, Sven
    Schmidt, Joachim
    Irouschek, Andrea
    PLOS ONE, 2021, 16 (04):
  • [44] Comparison of the effects of the McGRATH MAC, C-MAC, and Macintosh laryngoscopes on the intraocular pressures of non-ophthalmic patients: A prospective, randomised, clinical trial
    Ozkan, Ahmet Selim
    Akbas, Sedat
    Karaaslan, Erol
    Polat, Nihat
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2021, 40 (06)
  • [45] Comparison of BlockBuster® Laryngeal Mask Airway, King Vision® Video Laryngoscope, and flexible intubation scope for orotracheal intubation in adult patients with simulated immobilised cervical spine: A randomised controlled trial
    Sinha, Neha
    Bhat, Kharat
    Khanuja, Samiksha
    Gupta, Mahima
    Wadhwani, Megha
    Panjiar, Pratibha
    INDIAN JOURNAL OF ANAESTHESIA, 2025, 69 (03) : 296 - 301