Comparison of the C-MAC D-Blade Video Laryngoscope and the McCoy Laryngoscope in Difficult Airway Patients According to Arne Multivariate Risk Classification: A Randomised Prospective Trial

被引:0
|
作者
Duran, M. [1 ]
Yilmaz, N. [1 ]
Tepe, M. [1 ]
Kaya, R. [2 ]
Dogukan, M. [1 ]
Nakir, H. [3 ]
Magac, M. S. [4 ]
机构
[1] Adiyaman Univ, Fac Med, Dept Anesthesiol & Reanimat, Adiyaman, Turkiye
[2] Private Yeni Hayat Hosp, Dept Anesthesiol & Reanimat, Osmaniye, Turkiye
[3] Nazilli State Hosp, Dept Anesthesiol & Reanimat, Aydin, Turkiye
[4] Balikesir State Hosp, Dept Anesthesiol & Reanimat, Balikesir, Turkiye
关键词
C-MAC D-blade video laryngoscope; difficult airway; McCoy laryngoscope; TRACHEAL INTUBATION; MANAGEMENT; BOUGIE;
D O I
10.4103/njcp.njcp_422_24
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Difficult intubation is an important cause of morbidity and mortality during anaesthesia. Detection of patient with difficult airway is very important. Arne multivariate risk classification score is one of the tests that is used to detect this difficult airway patients. McCoy direct laryngoscope and the C-MAC videolaryngoscope are parts of among the tools that are currently used for these patients. Aim:This study aimed to compare the intubation success and access the quality of difficult airway using the McCoy direct laryngoscope and the C-MAC video laryngoscope. Methods:Included in this study were 100 patients scheduled for elective surgery, ASA I-III, who had the Arne multivariate risk classification score >11. The patients were randomly divided into the C-MAC D-Blade video laryngoscope (n = 50) and the McCoy laryngoscope (n = 50). The Mallampati score, Arne multivariate score, intubation success, required time for intubation, number of intubation attempts, required time to visualize the glottis, need for auxiliary equipment, and complications were recorded. Results:No differences in the demographic data were observed between the two groups (P > 0.05). In addition, no differences were observed between the groups in the required time to visualize the glottis (P = 0.801) or the Arne score (P = 0.619). The rate of use of gum elastic bougies in Grup C-MAC was lower (P = 0.014), and the intubation success rate was higher during the first attempt (P = 0.016). The intubation time was longer in the McCoy group (P = 0.017). Conclusion:The C-MAC D-Blade video laryngoscope was superior to the McCoy direct laryngoscope for difficult-to-intubate patients due to the shorter required time for intubation, higher intubation success rate, and lesser need for auxiliary equipment.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 45 条
  • [21] Comparison of McGrath® Series 5 video laryngoscope with Macintosh laryngoscope: A prospective, randomised trial in patients with normal airways
    Sargin, Mehmet
    Uluer, Mehmet Selcuk
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (04) : 869 - 874
  • [22] Comparison of Macintosh laryngoscope, non-channelled (C-MAC video-laryngoscope) and channelled laryngoscope (Airtraq) for intubation in lateral position - A prospective randomized controlled study
    Sultana, Farheen
    Nikhar, Sapna Annaji
    Durga, Padmaja
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2021, 40 : 30 - 34
  • [23] Out-of-hospital airway management in trauma patients. Experiences with the C-MAC® video laryngoscope
    Hossfeld, B.
    Jongebloed, A.
    Lampl, L.
    Helm, M.
    UNFALLCHIRURG, 2016, 119 (06): : 501 - 507
  • [24] A comparative study of the C-MAC D-blade videolaryngoscope and McCoy laryngoscope for oro-tracheal intubation with manual in-line stabilization of neck in patients undergoing cervical spine surgery
    Kumari, Astha
    Choudhuri, Pratiti
    Agrawal, Nidhi
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2023, 39 (03) : 435 - 443
  • [25] Comparison of conventional C-MAC video laryngoscope guided intubation by anesthesia trainees with and without Frova endotracheal introducer: A randomized clinical trial
    Arasu, Meenupriya
    Rudingwa, Priya
    Satyaprakash, Mv S.
    Panneerselvam, Sakthirajan
    Kuberan, Aswini
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2020, 36 (04) : 483 - 488
  • [26] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Paik, Hyesun
    Park, Hee-Pyoung
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [27] Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial
    Aziz, M. F.
    Bayman, E. O.
    Van Tienderen, M. M.
    Todd, M. M.
    Brambrink, A. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 118 - 123
  • [28] Comparison of Efficacy of Intubation with HugeMed Non-channelled Video Laryngoscope, McCoy and Macintosh Laryngoscope in Simulated Difficult Laryngoscopy Using Rigid Cervical Collar: A Prospective Randomized Trial
    Murdeshwar, Greeshma N.
    Yashodha, V.
    Poolandevi, Kempaiah
    Malini, S.
    ANNALS OF AFRICAN MEDICINE, 2024, 23 (03) : 358 - 364
  • [29] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Huang, Ping
    Zhou, Renlong
    Lu, Zhixing
    Hang, Yannan
    Wang, Shanjuan
    Huang, Zhenling
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [30] C-MAC D-Blade vs Airtraq for Intubation with Manual Inline Axial Stabilisation- A Randomised Clinical Trial
    Mani, Nikitha
    Palanisamy, Nagalakshmi
    Zachariah, Mamie
    George, Sagiev Koshy
    Dsilva, Allen Aloysius
    Johns, Jemmie Rachel
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (01)