A novel label-free immunosensor for detection of VEGF using FFT admittance voltammetry

被引:0
作者
Heidari, Negar [1 ]
Sajedi, Reza Hassan [4 ]
Kharat, Ali Nemati [1 ]
Bonakdar, Alireza [5 ,6 ]
Mirzazadeh, Jalil [7 ]
Qaraei, Kianoush Kazemi [1 ]
Norouzi, Parviz [1 ,2 ,3 ]
机构
[1] Univ Tehran, Chem Fac, Sch Sci, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] York Univ, Lassonde Sch Engn, Dept Elect Engn & Comp Sci, Toronto, ON, Canada
[4] Tarbiat Modares Univ, Fac Sci, Dept Biochem & Biophys, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Med Nanotechnol & Tissue Engn Res Ctr, Tehran, Iran
[6] Shahid Beheshti Univ Med Sci, Sch Adv Technol Med, Dept Tissue Engn & Appl Cell Sci, Tehran 1983963113, Iran
[7] R&D Ctr IKCO, 14th Karaj Rd, Tehran, Iran
关键词
Vascular endothelial growth factor (VEGF); Label-free Immunosensor; Admittance measurement; FFT voltammetry; SENSITIVE ELECTROCHEMICAL IMMUNOSENSOR; SELF-ASSEMBLED MONOLAYERS; SQUARE-WAVE VOLTAMMETRY; REAL-TIME; NANOCOMPOSITE; ELECTRODE;
D O I
10.1016/j.bioelechem.2025.108948
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study presents a novel, label-free electrochemical immunosensor for the detection of vascular endothelial growth factor (VEGF), a crucial tumor biomarker. The immunosensor was developed by electrochemical deposition of gold nanoparticles-reduced graphene oxide (AuNPs-rGO) nanocomposite on glassy carbon (GC) and screen-printed carbon (SPC) electrodes. A specific monoclonal antibody against VEGF was immobilized on the electrode surface through a carbodiimide coupling reaction. Field Emission Scanning Electron Microscopy (FESEM), X-ray Diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) have been used to characterize the developed immunosensor. For quantitative measurement of VEGF, fast Fourier transformation admittance voltammetry was employed by applying a special potential waveform on the immunosensor and sampling the currents. The response was determined by measuring changes in the electrode admittance caused by the adsorption of VEGF molecules, without the use of a redox probe. Under optimal conditions, the immunosensor responses were within a linear detection range for VEGF from 0.1 to 10,000 pg/ml and from 10 to 10,000 pg/ml, with notably low detection limits of 29.1 fg/ml and 352 fg/ml for the modified GC and SPC electrodes, respectively. The sensor exhibits minimal interference from common serum proteins, making it a promising candidate for sensitive, low-cost commercialization.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Aptamer biosensor for label-free square-wave voltammetry detection of angiogenin [J].
Li, Lidong ;
Zhao, Hongtao ;
Chen, Zhengbo ;
Mu, Xiaojiao ;
Guo, Lin .
BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) :261-266
[22]   Ultrasensitive Fluorescent "ON-OFF" Label-Free Immunosensor for Detection of Vitellogenin of Marine Medaka [J].
Qi, Chong ;
Yang, Ailing ;
Wang, Huaidong ;
Zhang, Zhenzhong ;
Wang, Jun .
CHEMOSENSORS, 2022, 10 (12)
[23]   Multilayer Label-Free Non-Faradic Electrochemical Impedance Immunosensor for Cortisol Detection [J].
Gupta, Chinmay ;
Pattanayek, Sudip Kumar ;
Mukherjee, Biswarup ;
Kumar, Sachin .
IEEE SENSORS JOURNAL, 2024, 24 (03) :2413-2420
[24]   Graphene Nanoplatelets/Chitosan-Modified Electrochemical Immunosensor for the Label-Free Detection of Haptoglobin [J].
Adhikari, Juthi ;
Mohd-Naim, Noor Faizah ;
Ahmed, Minhaz Uddin .
IEEE SENSORS JOURNAL, 2021, 21 (04) :4176-4183
[25]   Carcinoembryonic Antigen Admittance Biosensor Based on Au and ZnO Nanoparticles Using FFT Admittance Voltammetry [J].
Norouzi, Parviz ;
Gupta, Vinod Kumar ;
Faridbod, Farnoush ;
Pirali-Hamedani, Morteza ;
Larijani, Bagher ;
Ganjali, Mohammad Reza .
ANALYTICAL CHEMISTRY, 2011, 83 (05) :1564-1570
[26]   A novel label-free electrochemical immunosensor modified by glutathione and hyaluronic acid for the ultrasensitive and ultraselective detection of brucellosis in dilute serum [J].
Chen, Lihua ;
Zhao, Shiyi ;
Liu, Mingchao ;
Wu, Peng ;
Chen, Chuangfu .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 287 :510-516
[27]   Label-free immunosensor for the detection of kanamycin using Ag@Fe3O4 nanoparticles and thionine mixed graphene sheet [J].
Yu, Shujun ;
Wei, Qin ;
Du, Bin ;
Wu, Dan ;
Li, He ;
Yan, Liangguo ;
Ma, Hongmin ;
Zhang, Yong .
BIOSENSORS & BIOELECTRONICS, 2013, 48 :224-229
[28]   Label-free bead-based metallothionein electrochemical immunosensor [J].
Nejdl, Lukas ;
Hoai Viet Nguyen ;
Richtera, Lukas ;
Krizkova, Sona ;
Guran, Roman ;
Masarik, Michal ;
Hynek, David ;
Heger, Zbynek ;
Lundberg, Karin ;
Erikson, Kristofer ;
Adam, Vojtech ;
Kizek, Rene .
ELECTROPHORESIS, 2015, 36 (16) :1894-1904
[29]   Label-Free Immunosensor for the Determination of Microcystin-LR in Water [J].
Almeida de Oliveira, Ravila ;
Zanato, Nicole ;
Cruz Vieira, Iolanda .
ELECTROANALYSIS, 2020, 32 (10) :2166-2173
[30]   Label-free immunosensor based on gold nanoparticle silver enhancement [J].
Yang, Minghui ;
Wang, Cunchang .
ANALYTICAL BIOCHEMISTRY, 2009, 385 (01) :128-131