Biomechanical study of a modified application of Ilizarov external mini-fixator for metacarpal neck fractures: a comparative analysis

被引:0
作者
Chen Xie [1 ]
Yanchen Dong [2 ]
Zhaozhe Yao [3 ]
Zongyu Li [4 ]
机构
[1] Department of hand surgery, The 960th Hospital of PLA, No.25 Shifan Road, Tianqiao District, Shandong, Jinan
[2] Department of outpatient, The 960th Hospital of PLA, No.25 Shifan Road, Tianqiao District, Shandong, Jinan
[3] Department of trauma center, The 960th Hospital of PLA, No.25 Shifan Road, Tianqiao District, Shandong, Jinan
关键词
Biomechanical study; Ilizarov external mini-fixator; Metacarpal neck fractures; Modified application;
D O I
10.1186/s13018-025-05795-z
中图分类号
学科分类号
摘要
Background: Metacarpal neck fractures are common and there are numerous surgical methods available, but each has certain disadvantages and limitations. We modified the conventional Ilizarov external mini-fixator and this study is designed to compare the biomechanical stability of a modified Ilizarov external mini-fixator with conventional fixation methods for metacarpal neck fractures and to provide a basis for its clinical application. Methods: Forty fresh porcine metacarpal specimens were used to create metacarpal neck fracture models. The specimens were randomly assigned to four fixation groups (n = 10) as follows: (1) modified Ilizarov external mini-fixator (IEF), (2) retrograde crossed Kirschner wires (KW), (3) antegrade intramedullary Kirschner wires (IK), and (4) locking plate fixation (LP). In the IEF group, the modified design involved crossing two Kirschner wires (K-wires) through the fracture line, with their tails bent twice and connected to the external fixator frame. Biomechanical testing was performed using a modified three-point bending test. Maximum fracture force and bending stiffness were calculated from the force-displacement curves. Kruskal–Wallis test was used to compare statistical differences in maximum fracture force and stiffness among the groups, followed by post hoc pairwise comparisons adjusted with Bonferroni corrections. Results: The median maximum fracture force values (± interquartile range, IQR) for each group were as follows: IEF 160.3 ± 55.6 N, LP 173.5 ± 42.6 N, KW 91.1 ± 23.1 N, and IK 79.8 ± 37.8 N. The corresponding stiffness values were as follows: IEF 29.5 ± 10.4 N/mm, LP 32.9 ± 10.4 N/mm, KW 17.2 ± 11.3 N/mm, and IK 18.2 ± 13.7 N/mm. The IEF group demonstrated significantly higher maximum fracture force and stiffness than the KW and IK groups; however, no statistically significant differences were observed in the IEF group compared with the LP group. Conclusion: The modified Ilizarov external mini-fixator provided significantly greater biomechanical stability for metacarpal neck fractures than retrograde crossed K-wires and antegrade intramedullary K-wires, achieving comparable performance to the locking plate system. This modified design combines the simplicity and minimally invasive advantages of K-wire fixation with enhanced stability, potentially facilitating early joint mobilization and minimizing the risk of complication. © The Author(s) 2025.
引用
收藏
相关论文
共 5 条
  • [1] A Biomechanical Study Comparing Different Configurations of the Ilizarov Mini-fixator and Plate Fixation
    Nishimura, Reiji
    Ogino, Naohiko
    Miyawaki, Takeshi
    Matsuura, Shintaro
    Fujii, Mikako
    Akaishi, Wataru
    Bo, Hideaki
    JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 1 (02): : 35 - 43
  • [2] Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study
    Christopher A. Becker
    Christian Kammerlander
    Adrian Cavalcanti Kußmaul
    Matthias Woiczinski
    Christoph Thorwächter
    Christian Zeckey
    Fabian Sommer
    Christoph Linhart
    Simon Weidert
    Eduardo M. Suero
    Wolfgang Böcker
    Axel Greiner
    BioMedical Engineering OnLine, 18
  • [3] Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study
    Becker, Christopher A.
    Kammerlander, Christian
    Kussmaul, Adrian Cavalcanti
    Woiczinski, Matthias
    Thorwaechter, Christoph
    Zeckey, Christian
    Sommer, Fabian
    Linhart, Christoph
    Weidert, Simon
    Suero, Eduardo M.
    Boecker, Wolfgang
    Greiner, Axel
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (1)
  • [4] A Comparative Analysis of Socon CS and Socon Pedicle Screws in View of their Use for Treatment of Osteoporotic Fractures of the Thoracolumbal Spine. A Biomechanical Study
    Janu, I.
    Kocis, J.
    Navrat, T.
    Florian, Z.
    Wendsche, P.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (04) : 334 - 338
  • [5] Is just one screw really enough? Single- versus double-screw in the medial malleolus in supination-external rotation ankle fractures: A comparative biomechanical study using partially threaded cancellous screws
    Giordano, Vincenzo
    Rodrigues, Aliny
    Voelcker, Luiza
    Alves, Gabriel
    Pires, Robinson Esteves
    Freitas, Anderson
    Belangero, William Dias
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (02):