High-Flow Nasal Aerosol Therapy; Regional Aerosol Deposition and Airway Responsiveness

被引:0
|
作者
Potla, Srinivasa [1 ]
Smaldone, Gerald C. [1 ]
机构
[1] SUNY Stony Brook, Dept Med, Div Pulm Crit Care & Sleep Med, Med Ctr, Stony Brook, NY 11794 USA
关键词
aerosol deposition; breath-enhanced jet nebulizer; high-flow nasal cannula; IN-VIVO DEPOSITION; CANNULA; MECHANISMS; DELIVERY; OXYGEN;
D O I
10.1089/jamp.2024.0026
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: In normal subjects, during tidal breathing, aerosols deposit by settling in small airways. With obstructive lung disease (OLD), collapse of airways during expiration causes turbulence and increased deposition in central airways. High-flow nasal cannula (HFNC) therapy, washing out dead space, may affect deposition mechanisms and drug delivery. This study compared aerosol deposition and airway responsiveness in OLD after traditional and HFNC nebulization therapy.Methods: Twelve subjects with moderate to severe OLD participated in a two-day study. Spirometry was measured pre- and post-aerosol inhalation. On Day 1 (D1) subjects tidally inhaled radiolabeled albuterol (99mTc DTPA) by mouth via AeroTech II, (Biodex. Shirley, NY). Day 2 (D2) inhalation was via HFNC using i-AIRE (InspiRx, Inc. Somerset, NJ). The HFNC system (60 L/m) was infused by syringe pump at 50 mL/h. D2 lung deposition was monitored in real time by gamma camera to match D1. Pre and post heart rate, O2 sat, and nasopharyngeal deposition (NP) were measured. Mechanistic contributions were modeled using multiple linear regression (MLR) of deposition rate (DR mu g/m) as a function of breathing frequency, airway geometry (FEV1), and parenchymal integrity (DLCO).Results: Albuterol lung depositions were matched (p = 0.13) with D1 central/peripheral (sC/P) ratios 1.99 +/- 0.98. Following HFNC, peripheral deposition increased (31% +/- 33%, sC/P = 1.51 +/- 0.43, p = 0.01). D2/D1% change FVC increased by 16.1 +/- 16.7% (p = 0.003). NP deposition averaged 333% of lung. Heart rate and O2 sat were unaffected (p = 0.31, p = 0.63 respectively). DR analysis was markedly different between D1 (R2 = 0.82) and D2 (R2 = 0.12).Conclusion: In subjects with OLD, HFNC nebulization at 60 L/min was well tolerated and increased peripheral drug delivery. Spirometry significantly improved. Systemic effects were undetected indicating limited nasal absorption. MLR demonstrated that different mechanisms of deposition govern traditional vs HFNC aerosol delivery. Breath-enhanced nebulization via HFNC may provide controllable and effective aerosol therapy in OLD.
引用
收藏
页码:338 / 345
页数:8
相关论文
共 50 条
  • [21] High-flow nasal therapy - modelling the mechanism
    Lumb, A. B.
    Thomas, C. R.
    ANAESTHESIA, 2019, 74 (04) : 420 - 423
  • [22] Aerosol drug delivery to the lungs during nasal high flow therapy: an in vitro study
    Wallin, Martin
    Tang, Patricia
    Chang, Rachel Yoon Kyung
    Yang, Mingshi
    Finlay, Warren H.
    Chan, Hak-Kim
    BMC PULMONARY MEDICINE, 2019, 19 (1)
  • [23] Measurement of airway pressure during high-flow nasal therapy in apnoeic oxygenation: a randomised controlled crossover trial*
    Riva, T.
    Meyer, J.
    Theiler, L.
    Obrist, D.
    Butikofer, L.
    Greif, R.
    Nabecker, S.
    ANAESTHESIA, 2021, 76 (01) : 27 - 35
  • [24] Risk of Aerosol Formation During High-Flow Nasal Cannula Treatment in Critically Ill Subjects
    Bem, Reinout A.
    van Mourik, Niels
    Klein-Blommert, Rozalinde
    Spijkerman, Ingrid Jb
    Kooij, Stefan
    Bonn, Daniel
    Vlaar, Alexander P.
    RESPIRATORY CARE, 2021, 66 (06) : 891 - 896
  • [25] Influences of Cannula Size and Flow Rate on Aerosol Drug Delivery Through the Vapotherm Humidified High-Flow Nasal Cannula System
    Perry, Sarah A.
    Kesser, Kenneth C.
    Geller, David E.
    Selhorst, Dawn M.
    Rendle, John K.
    Hertzog, James H.
    PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (05) : E250 - E256
  • [26] The Impact of High-Flow Nasal Cannula Device, Nebulizer Type, an Placement on Trans-Nasal Aerosol Drug Delivery
    Li, Jie
    Williams, Lucas
    Fink, James B.
    RESPIRATORY CARE, 2022, 67 (01) : 1 - 8
  • [27] Pressurized Metered Dose Inhaler Aerosol Delivery Within Nasal High-Flow Circuits: A Bench Study
    Szychowiak, Piotr
    Gensburger, Samuel
    Bocar, Thomas
    Landel, Cassandre
    Philippe, Marion
    Le Pennec, Deborah
    Cabrera, Maria
    Mordier, Lydiane
    Vecellio, Laurent
    Reminiac, Francois
    Heuze-Vourc'h, Nathalie
    Ehrmann, Stephan
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2021, 34 (05) : 303 - 310
  • [28] Feasibility of Aerosol Bronchodilators Delivery Through High-Flow Nasal Cannula in Pediatric Subjects With Respiratory Distress
    Al-Subu, Awni M.
    Nguyen, Vu T.
    AlAli, Yousef
    Yngsdal-Krenz, Rhonda A.
    Lasarev, Michael R.
    Eldridge, Marlowe W.
    Hagen, Scott A.
    RESPIRATORY CARE, 2020, 65 (10) : 1464 - 1469
  • [29] High-flow nasal cannula compared with continuous positive airway pressure: a bench and physiological study
    Vieira, Fernando
    Bezerra, Frank Silva
    Coudroy, Remi
    Schreiber, Annia
    Telias, Irene
    Dubo, Sebastian
    Cavalot, Giulia
    Pereira, Sergio Martins
    Piraino, Thomas
    Brochard, Laurent Jean
    JOURNAL OF APPLIED PHYSIOLOGY, 2022, 132 (06) : 1580 - 1590
  • [30] The Mechanisms of Benefit of High-Flow Nasal Therapy in Stable COPD
    Zantah, Massa
    Pandya, Aloknath
    Jacobs, Michael R.
    Criner, Gerard J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 7