The calculated and the rapid equilibrium dialyzed human serum free testosterone by LC-MS/MS and their performances in PCOS diagnosis

被引:0
|
作者
Rao, Menghua [1 ,2 ]
Guo, Zaixin [3 ,4 ]
Dong, Heng [1 ,2 ]
Ho, Chung Shun [5 ]
Chen, Xiuru [1 ,2 ]
Li, Jin [6 ]
Hong, Xinyu [3 ,4 ]
You, Yang [3 ,4 ]
Hao, Yanfang [3 ,4 ]
Hu, Pan [3 ,4 ]
She, Xuhui [1 ,2 ]
Yu, Qi [3 ,4 ]
机构
[1] Guangzhou KingMed Ctr Clin Lab Co Ltd, Clin Mass Spectrometry Ctr, Guangzhou Int Bioisl, 10 Luoxuan 3rd Rd, Guangzhou 510005, Guangdong, Peoples R China
[2] Guangzhou Med Univ, KingMed Coll, Lab Med, Guangzhou 511436, Guangdong, Peoples R China
[3] Peking Union Med Coll, Peking Union Med Coll Hosp, Dept Obstet & Gynecol, Natl Clin Res Ctr Obstet & Gynecol Dis, Beijing 100730, Peoples R China
[4] Chinese Acad Med Sci, Beijing 100730, Peoples R China
[5] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Chem Pathol, Biomed Mass Spectrometry Unit, Hong Kong, Peoples R China
[6] Guangzhou Int Bioisl, Clin Biochem & Immunol Testing Ctr, Guangzhou KingMed Ctr Clin Lab Co Ltd, 10 Luoxuan Third Rd, Guangzhou City 510005, Guangdong, Peoples R China
关键词
Free testosterone; Equilibrium dialysis; LC-MS/MS; Polycystic ovary syndrome; CLINICAL UTILITY; ULTRAFILTRATION; WOMEN;
D O I
10.1016/j.cca.2025.120210
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: To compare the calculated and the rapid equilibrium dialyzed (ED) human serum free testosterone (FT) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and to explore their performances in polycystic ovary syndrome (PCOS) diagnosis. Methods: A rapid ED LC-MS/MS method for serum FT was established and validated for linearity, lower limit of the measuring interval (LLMI), imprecision, trueness, stability, dilution, matrix specificity and carryover. The validated ED LC-MS/MS (ED-FT) was compared with calculated LC-MS/MS method from Vermeulen's formula (cFT) for FT measurement in 139 PCOS patients and 100 healthy controls. The performances of total testosterone (TT), ED-FT and cFT by LC-MS/MS in PCOS diagnosis were investigated with the same cohorts. Results: The linearity range of ED-FT was 1.74-890 pmol/L, with a LLMI at 1.74 pmol/L. The intra-assay and inter-assay imprecision were < 3.8 % and < 5.9 %. The trueness was acceptable with recoveries of 92.9 %-108.2 %. The equilibrium dialysis time was 4 h. The two FT methods displayed systematic and proportional differences and cFT showed significant positive deviations compared to ED-FT. Receiver operating characteristic curve analysis proved that ED-FT outperformanced in PCOS diagnosis with the an area under the curve at 0.973, sensitivity of 89.93 % and specificity of 96.00 %. Conclusions: This study established a rapid, accurate and sensitive ED LC-MS/MS method for serum FT. ED-FT is optimal compared to TT and cFT by LC-MS/MS in PCOS diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous quantification of total and free testosterone in human serum by LC-MS/MS
    Huang, Rongmei
    Hong, Yi
    Wu, Yike
    Li, Weifeng
    Liu, Wenlan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (27) : 6851 - 6861
  • [2] Free Cortisol Measurement in Human Serum by Combined Equilibrium Dialysis and LC-MS/MS
    Twentyman, J.
    Cradic, K.
    Grebe, S.
    Singh, R.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A190 - A190
  • [3] Testosterone analysis in serum of women by LC-MS/MS
    Kushmir, MM
    Rockwood, AL
    Yue, B
    Roberts, WL
    Meikle, AW
    CLINICAL CHEMISTRY, 2004, 50 (06) : A91 - A92
  • [4] Harmonization of Immunoassay Reference Intervals with LC-MS/MS for Total and Calculated Free Testosterone Measurement
    Li, S.
    Povse, P.
    Lattanzio, F.
    Patel, K.
    Kerlin, R.
    Jones, J.
    CLINICAL CHEMISTRY, 2024, 70
  • [5] A sensitive assay for the measurement of testosterone in human serum by LC-MS/MS.
    Nelson, RE
    Singh, RJ
    Grebe, SK
    CLINICAL CHEMISTRY, 2004, 50 (06) : A106 - A106
  • [6] SIMULTANEOUS QUANTIFICATION OF TESTOSTERONE AND ANDROSTENEDIONE IN HUMAN SERUM USING LC-MS/MS
    Joos, E.
    Van Bocxlaer, J.
    Vandermarliere, M.
    Croes, K.
    ACTA CLINICA BELGICA, 2010, 65 (03): : 215 - 215
  • [7] Quantification of free and protein bound uremic toxins in human serum by LC-MS/MS: Comparison of rapid equilibrium dialysis and ultrafiltration
    Fabresse, Nicolas
    Uteem, Imteyaz
    Lamy, Elodie
    Massy, Ziad
    Larabi, Islam Amine
    Alvarez, Jean-Claude
    CLINICA CHIMICA ACTA, 2020, 507 : 228 - 235
  • [8] Total testosterone quantitative measurement in serum by LC-MS/MS
    Wang, Yuesong
    Gay, Gabrielle D.
    Botelho, Julianne Cook
    Caudill, Samuel P.
    Vesper, Hubert W.
    CLINICA CHIMICA ACTA, 2014, 436 : 263 - 267
  • [9] LC-MS/MS methods for the measurement of androstenedione and testosterone in serum
    Erdogan, E.
    Kushnir, M. M.
    Yue, B.
    Blamires, T. L.
    Roberts, W. L.
    Meikle, A. W.
    Rockwood, A. L.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A184 - A184
  • [10] An LC-MS/MS assay for analysis of equilibrium angiotensin II in human serum
    Bernstone, Laura
    Adaway, Joanne E.
    Keevil, Brian G.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (05) : 422 - 433