Eye lens dose estimations in chest computed tomography examinations using Monte Carlo simulations in a Siemens SOMATOM perspective scanner

被引:0
|
作者
Leon, M. I. [1 ]
Quispe, B. [1 ]
Gutierrez, L. [2 ]
Pena, J. D. [1 ]
Waldo, G. [1 ]
Ceron, P. [3 ]
Hernandez, M. A. [2 ]
Vega, H. R. [4 ]
Montes, E. [1 ]
Reyes, U. [5 ]
Vallejo, M. [1 ]
Sosa, M. [1 ]
机构
[1] Univ Guanajuato, Dept Phys Engn, DCI, Leon 37150, Gto, Mexico
[2] Mexican Inst Social Secur, Hlth Res Div, High Specialty Med Unit T1, Leon 31320, Gto, Mexico
[3] Univ Quintana Roo, Dept Environm Sci DCIyT, Chetmal 77019, Mexico
[4] Autonomous Univ Zacatecas, Acad Unit Nucl Studies, Zacatecas, 98000, Zac, Mexico
[5] State Ctr Cancerol, Durango Hlth Serv, Durango 34000, Dgo, Mexico
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2024年 / 22卷 / 04期
关键词
Monte Carlo method; eye lens; radiation dosage; tomography; X-RAY; CT EXAMINATIONS; RADIATION; REDUCTION; DOSIMETRY; EXPOSURE; ORGANS;
D O I
10.61186/ijrr.22.4.853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The radiation dose received by the eye lens when a chest computed tomography (CT) scan is performed, is generally not recorded in clinical practice, particularly due to the distance of this organ from the X-ray beam. Material and Methods: The absorbed dose in the eye lens was determined by Monte Carlo NParticle version 5 (MCNP5) calculations and thermoluminescence dosimetry (TLD). Two models of the CT scanner and patient were constructed using the MCNP5 code. The first model was the Bottle Manikin Absorber (BOMAB), which includes the main structures of the eye, and the second was the computational voxelized phantom MAX06. In addition, measurements were carried out in 21 adult patients, which underwent a chest CT study in a Siemens SOMATOM Perspective scanner. Results: Average Monte Carlo values for the absorbed dose of 16.4 +/- 0.4 mGy and 1.97 +/- 0.04 mSv for the effective dose were obtained when the BOMAB model was used. Mean values of 13.3 +/- 0.3 mGy and 1.59 +/- 0.04 mSv, respectively, were obtained for the absorbed dose and effective dose for the MAX06 phantom. TLD measurements gave average values of 12.66 +/- 1.33 mGy and 1.52 +/- 0.16 mSv for absorbed dose and effective dose, respectively, in simple chest scans, and 7.60 +/- 0.63 mGy and 0.91 +/- 0.07 mSv, respectively, for simple contrast-enhanced studies. Conclusions: The results of the Monte Carlo simulations with BOMAB and voxelized phantoms in our study agree relatively well with each other.
引用
收藏
页码:853 / 860
页数:8
相关论文
共 30 条
  • [21] Monte Carlo simulation of eye lens dose reduction from CT scan using organ based tube current modulation
    Huang, Ying
    Zhuo, Weihai
    Gao, Yiming
    Liu, Haikuan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 72 - 75
  • [22] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    Pontana, Francois
    Duhamel, Alain
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Hachulla, Anne-Lise
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 636 - 643
  • [23] Improving Calculations of Electron Eye-lens Operational Dose Coefficients Using the Monte Carlo Codes PENELOPE and MCNP6.2
    Dubeau, Jacques
    Sun, Jiansheng
    Djeffal, Salah
    Ali, Fawaz
    HEALTH PHYSICS, 2024, 126 (05): : 339 - 345
  • [24] Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software
    Kim, Eun-Kyung
    Han, Won-Jeong
    Choi, Jin-Woo
    Battulga, Bulgan
    IMAGING SCIENCE IN DENTISTRY, 2018, 48 (01) : 21 - 30
  • [25] Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch
    May, Matthias S.
    Deak, Paul
    Kuettner, Axel
    Lell, Michael M.
    Wuest, Wolfgang
    Scharf, Michael
    Keller, Andrea K.
    Haeberle, Lothar
    Achenbach, Stephan
    Seltmann, Martin
    Uder, Michael
    Kalender, Willi A.
    EUROPEAN RADIOLOGY, 2012, 22 (03) : 569 - 578
  • [26] Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system
    Sookpeng S.
    Butdee C.
    Emergency Radiology, 2017, 24 (3) : 233 - 239
  • [27] Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality
    Kawauchi, Satoru
    Chida, Koichi
    Moritake, Takashi
    Hamada, Yusuke
    Tsuruta, Wataro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 192 - 199
  • [28] Evaluation of Organ Doses for Pediatric Computed Tomography Using a Newly Designed Radiophotoluminescence Glass Dosimeter and Comparison with a Monte Carlo Simulation-based Dose Calculator
    Chang, Weishan
    Koba, Yusuke
    HEALTH PHYSICS, 2021, 120 (03): : 288 - 295
  • [29] COMPARISON OF PEDIATRIC LENS DOSE MEASUREMENTS BETWEEN AXIAL SCAN MODE WITHOUT ACTIVE COLLIMATOR AND HELICAL SCAN MODE WITH ACTIVE COLLIMATOR BY USING A 64 DETECTOR-ROW COMPUTED TOMOGRAPHY SCANNER
    Masuda, Takanori
    Funama, Yoshinori
    Nakaura, Takeshi
    Sato, Tomoyasu
    Urayama, Kotaro
    Kiguchi, Masao
    Oku, Takayuki
    Arao, Shinichi
    Ono, Atsushi
    Hiratsuka, Junichi
    Awai, Kazuo
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (19) : 1522 - 1527
  • [30] Quantification of the kV X-ray imaging dose during real-time tumor tracking and from three- and four-dimensional cone-beam computed tomography in lung cancer patients using a Monte Carlo simulation
    Nakamura, Mitsuhiro
    Ishihara, Yoshitomo
    Matsuo, Yukinori
    Iizuka, Yusuke
    Ueki, Nami
    Iramina, Hiraku
    Hirashima, Hideaki
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 173 - 181