Eye lens dose estimations in chest computed tomography examinations using Monte Carlo simulations in a Siemens SOMATOM perspective scanner

被引:0
|
作者
Leon, M. I. [1 ]
Quispe, B. [1 ]
Gutierrez, L. [2 ]
Pena, J. D. [1 ]
Waldo, G. [1 ]
Ceron, P. [3 ]
Hernandez, M. A. [2 ]
Vega, H. R. [4 ]
Montes, E. [1 ]
Reyes, U. [5 ]
Vallejo, M. [1 ]
Sosa, M. [1 ]
机构
[1] Univ Guanajuato, Dept Phys Engn, DCI, Leon 37150, Gto, Mexico
[2] Mexican Inst Social Secur, Hlth Res Div, High Specialty Med Unit T1, Leon 31320, Gto, Mexico
[3] Univ Quintana Roo, Dept Environm Sci DCIyT, Chetmal 77019, Mexico
[4] Autonomous Univ Zacatecas, Acad Unit Nucl Studies, Zacatecas, 98000, Zac, Mexico
[5] State Ctr Cancerol, Durango Hlth Serv, Durango 34000, Dgo, Mexico
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2024年 / 22卷 / 04期
关键词
Monte Carlo method; eye lens; radiation dosage; tomography; X-RAY; CT EXAMINATIONS; RADIATION; REDUCTION; DOSIMETRY; EXPOSURE; ORGANS;
D O I
10.61186/ijrr.22.4.853
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The radiation dose received by the eye lens when a chest computed tomography (CT) scan is performed, is generally not recorded in clinical practice, particularly due to the distance of this organ from the X-ray beam. Material and Methods: The absorbed dose in the eye lens was determined by Monte Carlo NParticle version 5 (MCNP5) calculations and thermoluminescence dosimetry (TLD). Two models of the CT scanner and patient were constructed using the MCNP5 code. The first model was the Bottle Manikin Absorber (BOMAB), which includes the main structures of the eye, and the second was the computational voxelized phantom MAX06. In addition, measurements were carried out in 21 adult patients, which underwent a chest CT study in a Siemens SOMATOM Perspective scanner. Results: Average Monte Carlo values for the absorbed dose of 16.4 +/- 0.4 mGy and 1.97 +/- 0.04 mSv for the effective dose were obtained when the BOMAB model was used. Mean values of 13.3 +/- 0.3 mGy and 1.59 +/- 0.04 mSv, respectively, were obtained for the absorbed dose and effective dose for the MAX06 phantom. TLD measurements gave average values of 12.66 +/- 1.33 mGy and 1.52 +/- 0.16 mSv for absorbed dose and effective dose, respectively, in simple chest scans, and 7.60 +/- 0.63 mGy and 0.91 +/- 0.07 mSv, respectively, for simple contrast-enhanced studies. Conclusions: The results of the Monte Carlo simulations with BOMAB and voxelized phantoms in our study agree relatively well with each other.
引用
收藏
页码:853 / 860
页数:8
相关论文
共 30 条
  • [1] Influence of dosimeter depth on estimating patient's eye lens dose in head computed tomography: A measurement and Monte Carlo simulation study
    Hirosawa, Ayaka
    Matsubara, Kosuke
    Fukuda, Atsushi
    Morioka, Yusuke
    Kitagawa, Masayasu
    Ogawa, Yoshinori
    RADIATION MEASUREMENTS, 2023, 166
  • [2] Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations
    Giansante, Louise
    Martins, Juliana C.
    Nersissian, Denise Y.
    Kiers, Karen C.
    Kay, Fernando U.
    Sawamura, Marcia V. Y.
    Lee, Choonsik
    Gebrim, Eloisa M. M. S.
    Costa, Paulo R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 308 - 320
  • [3] Calculation of radiation dose to the lens of the eye using Monte Carlo simulation
    Meriç, N
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 557 - 560
  • [4] Peak skin and eye lens radiation dose from brain perfusion CT: CTDIvol and Monte Carlo based estimations
    Lopez-Rendon, X.
    Stratis, A.
    Zhang, G.
    Coudyzer, W.
    Develter, W.
    Bogaerts, R.
    Bosmans, H.
    Zanca, F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [5] UTILIZING MONTE CARLO SIMULATIONS IN ESTIMATION OF OCCUPATIONAL EYE LENS DOSE BASED ON WHOLE BODY DOSIMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY
    Bozovic, Predrag M.
    Ciraj-Bjelac, Olivera F.
    Stankovic Petrovic, Jelena S.
    Arandjic, Danijela D.
    Ceklic, Sandra M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (04) : 375 - 379
  • [6] Occupational Radiation Dose, Especially for Eye Lens: Hp(3), in Medical Staff Members Involved in Computed Tomography Examinations
    Osanai, Minoru
    Sato, Hidenori
    Sato, Kana
    Kudo, Kohsei
    Hosoda, Masahiro
    Hosokawa, Shota
    Kitajima, Maiko
    Tsushima, Megumi
    Fujita, Akira
    Hosokawa, Yoichiro
    Saito, Yoko
    APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [7] Estimating organ dose in computed tomography using tube current modulation: A Monte Carlo simulation
    Hosseinzadeh, V
    Ghaffari, H.
    Rezaeyan, A.
    Deilami, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 575 - 581
  • [8] Estimation of Computed Tomography Dose Index (CTDI) Using Monte Carlo Simulation
    Talbi, Mohammed
    Aabid, Mohammed
    El Mansouri, M'hamed
    Nhila, Oussama
    Semghouli, Slimane
    Sebihi, Rajaa
    Choukri, Abdelmajid
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S103 - S109
  • [9] Monte Carlo Simulation of the Computed Tomography Dose Index (CTDI) Using GATE
    Mkimel, M.
    El Baydaoui, R.
    Mesradi, M. R.
    Tahiri, Z.
    Talasmat, K.
    Halimi, A.
    Krim, M.
    Saad, E.
    Hilali, A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2020, 17 (06) : 900 - 907
  • [10] Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
    Mohammadi, Gh R. Fallah
    Hesamnezhad, L.
    Mahdavi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 813 - 818