Chemical Imaging Optimization of Light Addressable Potentiometric Sensor on Amplitude-Phase Mode

被引:0
作者
Luo, Jiezhang [1 ]
Liu, Shibin [1 ]
Chen, Yinghao [1 ]
Tan, Jie [2 ]
Zhao, Wenbo [3 ]
Zheng, Yaoxin [4 ]
Yang, Yongyi [1 ]
Zhang, Yun [1 ]
Pan, Yiming [1 ]
Tan, Yue [1 ]
Li, Guifang [1 ]
Du, Yongqian [1 ]
Li, Huijuan [5 ]
机构
[1] Northwestern Polytech Univ, Sch Elect & Informat, Xian, Shaanxi, Peoples R China
[2] Xihua Univ, Sch Elect & Informat Engn, Chengdu, Sichuan, Peoples R China
[3] Northwestern Polytech Univ, Inst Flexible Elect, Xian, Shaanxi, Peoples R China
[4] Beijing Automat Control Equipment Inst, Beijing, Peoples R China
[5] Shaanxi Polytech Inst, Coll Elect Engn, Xianyang, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
amplitude-phase mode; chemical imaging; imaging quality; light addressable potentiometric sensor (LAPS); HIGH-SPEED; SPATIAL-RESOLUTION; LATERAL DIFFUSION; LAPS;
D O I
10.1002/elan.12003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Light-addressable potentiometric sensor (LAPS) is one of the label-free chemical imaging sensors and attractive for its flexible imaging capability coming from its unique addressing mechanism. Imaging quality of LAPS is limited by illumination intensity and stability of light source. In this study, the amplitude-phase mode, which combines the advantages of constant-bias mode and phase mode, is proposed. The role of amplitude-phase mode in suppressing illumination interference and improving imaging quality has been theoretically proven. Better spatial resolution and the more realistic imaging effect are realized by LAPS in amplitude-phase mode. The amplitude-phase mode LAPS provides a feasible implementation for improving LAPS spatial resolution under a reducing illumination intensity.
引用
收藏
页数:11
相关论文
共 53 条
[2]   INVESTIGATION OF CARRIER TRANSPORT THROUGH SILICON-WAFERS BY PHOTOCURRENT MEASUREMENTS [J].
BOUSSE, L ;
MOSTARSHED, S ;
HAFEMAN, D ;
SARTORE, M ;
ADAMI, M ;
NICOLINI, C .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (08) :4000-4008
[3]   FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[4]   Trench Bottom Optical Isolation for Suppressing Lateral Diffusion of Photocarriers in LAPS [J].
Chen, Dong ;
Hao, Zheng ;
Li, Xueliang ;
Liang, Jintao ;
Tong, Xingyuan .
IEEE SENSORS JOURNAL, 2023, 23 (10) :10538-10545
[5]   A closed-loop detection system based on orthogonal phase locking for EISCAP sensor [J].
Chen, Dong ;
Liang, Jin-tao ;
Tong, Xing-yuan ;
Li, Hong-zhou ;
Lai, Jun-xiang ;
Liu, Shi-bin .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 860
[6]   Decreasing lateral diffusion of photo-generated carriers for light-addressable potentiometric array by using meshed working electrode [J].
Chen, Dong ;
Liu, ShiBin ;
Yin, ShiMin ;
Liang, JinTao .
OPTICAL ENGINEERING, 2016, 55 (09)
[7]   A high-speed, flexible-scanning chemical imaging system using a light-addressable potentiometric sensor integrated with an analog micromirror [J].
Dasa, Anirban ;
Chen, Tsung-Cheng ;
Yang, Chia-Ming ;
Lai, Chao-Sung .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 :225-232
[8]   Odor Biosensors Based on Cell Expressing Olfactory Receptor: Recent Advances [J].
Deng, Hongchao ;
Nakamoto, Takamichi .
ANALYSIS & SENSING, 2024, 4 (05)
[9]   Device simulation of the light-addressable potentiometric sensor for the investigation of the spatial resolution [J].
Guo, Yuanyuan ;
Miyamoto, Ko-ichiro ;
Wagner, Torsten ;
Schoening, Micheal J. ;
Yoshinobu, Tatsuo .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 :659-665
[10]   LIGHT-ADDRESSABLE POTENTIOMETRIC SENSOR FOR BIOCHEMICAL SYSTEMS [J].
HAFEMAN, DG ;
PARCE, JW ;
MCCONNELL, HM .
SCIENCE, 1988, 240 (4856) :1182-1185