Long-Term Clinical Outcomes of Polymer-Free Sirolimus-Eluting Stent and Polymer-Coated Sirolimus-Eluting Stent in Patients with Type 2 Diabetes

被引:0
|
作者
Yang, Ou [1 ]
Teng, Yuhuan [1 ]
Zhang, Ruoxi [2 ]
Qu, Jie [1 ]
机构
[1] Jilin Univ, Dept Cadre Ward, Hosp 1, Changchun 130021, Jilin, Peoples R China
[2] Harbin Yinghua Hosp, Dept Cardiol, Harbin 150119, Heilongjiang, Peoples R China
来源
INTERNATIONAL JOURNAL OF NANOMEDICINE | 2024年 / 19卷
基金
中国博士后科学基金;
关键词
Polymer-free; polymer-coated; Nano Plus stent; drug-eluting stents; type 2 diabetes mellitus; optical coherence tomography; C-REACTIVE PROTEIN; OPTICAL COHERENCE TOMOGRAPHY; ACUTE CORONARY SYNDROMES; RE-ENDOTHELIALIZATION; RISK; THROMBOSIS; IMPLANTATION; ASSOCIATION; POPULATION; PRINCIPLES;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Introduction: Polymer-free sirolimus-eluting stent (PF-SES) possess multiple properties improving targeted drug elution and in-stent reendothelialization without the presence of polymers. The long-term clinical performance comparison between PF-SES and the latest generation polymer-coated sirolimus-eluting stents (SES), particularly regarding intravascular imaging assessment and in the type 2 Methods: We conducted a retrospective study involving 2646 diabetes patients meeting coronary artery disease (CAD) criteria underwent coronary stents in the real-world. All patients were divided into the PF-SES group and the SES group. Optical coherence tomography (OCT) was used to evaluate the imaging characteristics of in-stent reendothelialization. Patient information between the two groups was systematically compared in hospital and at 5-year follow-up. Results: In terms of basic characteristics, the proportion of current smoker and stable angina patients in the PF-SES group was significantly higher than that in the SES group. The PF-SES group exhibited significantly higher rate of left anterior descending (LAD) lesion and more stents per patients compared to the SES group. The value of minimum lumen area (MLA), neointimal area (NA) and neointimal thickness (NT) were higher in the PF-SES group. Additionally, the occurrence rates of heterogeneous, lipid layer, intimal tears, thrombi, and micro-vessels were notably lower in the PF-SES group compared to the SES group. A higher all-cause mortality was observed in the SES cohort. Discussion: PF-SES could effectively improve in-stent reendothelialization in patients with type 2 DM, with positive effects on survival rate and may, therefore, be considered as an alternative treatment option for improving clinical long-term outcomes.
引用
收藏
页码:11689 / 11700
页数:12
相关论文
共 50 条
  • [31] Comparative preclinical evaluation of a polymer- free sirolimus-eluting stent in porcine coronary arteries
    Sperling, Christian
    Waliszewski, Matthias W.
    Kherad, Behrouz
    Krackhardt, Florian
    THERAPEUTIC ADVANCES IN CARDIOVASCULAR DISEASE, 2019, 13 : 1 - 13
  • [32] The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence
    Chisari, Alberto
    Pistritto, Anna Maria
    Piccolo, Raffaele
    La Manna, Alessio
    Danzi, Gian Battista
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (09):
  • [33] Comparison of very early-phase vascular response to the CD34 antibody-covered sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent
    Goto, Hiroki
    Kitahara, Hideki
    Matsumoto, Tadahiro
    Tateishi, Kazuya
    Saito, Yuichi
    Kato, Ken
    Kobayashi, Yoshio
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2025,
  • [34] Cobalt chromium-based biodegradable polymer sirolimus-eluting stent: rationale, evidence and clinical experience
    Pan, D. R.
    Zhu, H.
    Hu, Z. Y.
    Pang, S.
    Wu, W.
    Tian, N. L.
    Xu, B.
    Iqbal, J.
    Zhang, Y. J.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (05): : 411 - 426
  • [35] Clinical and Angiographic Outcomes of the First Korean-made Sirolimus-Eluting Coronary Stent with Abluminal Bioresorbable Polymer
    Yang, Hyoung-Mo
    Seo, Kyoung-Woo
    Yoon, Junghan
    Kim, Hyo-Soo
    Chang, Kiyuk
    Lim, Hong-Seok
    Choi, Byoung-Joo
    Choi, So-Yeon
    Yoon, Myeong-Ho
    Lee, Seung-Hwan
    Ahn, Sung Gyun
    Youn, Young Jin
    Lee, Jun-Won
    Koo, Bon-Kwon
    Park, Kyung Woo
    Yang, Han-Mo
    Han, Jung-Kyu
    Seung, Ki-Bae
    Chung, Wook-Sung
    Kim, Pum-Joon
    Koh, Yoon-Seok
    Park, Hun-Jun
    Tahk, Seung-Jea
    KOREAN CIRCULATION JOURNAL, 2017, 47 (06) : 898 - 906
  • [36] Ultrathin, Biodegradable-Polymer Sirolimus-Eluting Stent vs Thin, Durable-Polymer Everolimus-Eluting Stent
    Nakamura, Masato
    Kadota, Kazushige
    Nakagawa, Yoshihisa
    Tanabe, Kengo
    Ito, Yoshiaki
    Amano, Tetsuya
    Maekawa, Yuichiro
    Takahashi, Akihiko
    Shiode, Nobuo
    Otsuka, Yoritaka
    Kawasaki, Tomohiro
    Hikichi, Yutaka
    Shite, Junya
    Kozuma, Ken
    Iijima, Raisuke
    Murakami, Yoshitaka
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (13) : 1324 - 1334
  • [37] Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated sirolimus-eluting stent: 12-month results from the FLEX Registry
    Lemos, Pedro A.
    Chandwani, Prakash
    Saxena, Sudheer
    Ramachandran, Padma Kumar
    Abhyankar, Atul
    Campos, Carlos M.
    Marchini, Julio Flavio
    Galon, Micheli Zanotti
    Verma, Puneet
    Sandhu, Manjinder Singh
    Parikh, Nikhil
    Bhupali, Ashok
    Jain, Sharad
    Prajapati, Jayesh
    BMJ OPEN, 2016, 6 (02):
  • [38] Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation
    Fu, Qiang
    Hu, Hongyu
    Chen, Wei
    Tan, Zhixu
    Li, Li
    Wang, Dezhao
    Chen, Buxing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2015, 8 (09): : 11068 - 11075
  • [39] Two-year Clinical Outcomes of Patients with Long Segments Drug-Eluting Stents: Comparison of Sirolimus-Eluting Stent with Paclitaxel-Eluting Stent
    Kim, Ung
    Lee, Sang-Hee
    Hong, Geu-Ru
    Park, Jong-Seon
    Shin, Dong-Gu
    Kim, Young-Jo
    Jang, Jae-Sik
    Yang, Tae-Hyun
    Kim, Dae-Kyeong
    Kim, Dong-Soo
    Kim, Dong-Kie
    Seol, Sang-Hoon
    Kim, Doo-Il
    Cho, Yoon-Kyung
    Kim, Hyung-Seop
    Nam, Chang-Wook
    Hur, Seung-Ho
    Kim, Kwon-Bae
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2011, 26 (10) : 1299 - 1304
  • [40] Vascular response profiles following a nano polymer-free sirolimus-eluting stent implantation assessed by optical coherence tomography in a porcine model
    Ma, Li
    Fu, Qiang
    Hu, Hongyu
    Chen, Wei
    Li, Li
    Tan, Zhixu
    Chen, Buxing
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (03) : 829 - 834