Automated insulin delivery systems in elderly patients with brittle type 2 diabetes

被引:1
作者
Caklili, Ozge Telci [1 ]
Cetin, Ferhat [2 ]
Ozkan, Melike [3 ]
Sahiner, Elif [4 ]
Cakmak, Ramazan [5 ]
Keskin, Ela [3 ]
Hacisahinogullari, Hulya [6 ]
Goncuoglu, Enver Sukru [2 ]
Yilmaz, M. Temel [7 ,8 ]
机构
[1] Kocaeli City Hosp, Clin Endocrinol & Metab, Kocaeli, Turkiye
[2] Turkish Diabet Assoc, Istanbul, Turkiye
[3] Demiroglu Bilim Univ, Endocrinol & Diabet Clin, Istanbul, Turkiye
[4] Sultan Abdulhamid Han Training & Res Hosp, Dept Dietet, Istanbul, Turkiye
[5] Med Pk Hosp Gaziosmanpasa, Dept Endocrinol & Metab, Istanbul, Turkiye
[6] Istanbul Univ, Fac Med, Dept Endocrinol & Metab, Istanbul, Turkiye
[7] Acibadem Diabet Ctr, Istanbul, Turkiye
[8] Arateus Diabet Inst, Istanbul, Turkiye
关键词
Geriatric diabetes; Elderly; Type; 2; diabetes; Pump; Automated insulin delivery; Cancer; Steroid; HYPOGLYCEMIA; TECHNOLOGY; ADULTS; MORTALITY; SAFETY; PUMP;
D O I
10.1016/j.diabres.2024.111913
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Geriatric diabetes is complicated by the frailty of this population, and hypoglycemia with insulin is not uncommon in these patients. Automated Insulin Delivery (AID) systems may provide better glycemic control in elderly patients with brittle type 2 diabetes. Methods: Thirty-four patients (>= 60 years) including cancer patients with brittle diabetes were switched to an AID system from multiple-dose insulin (MDI) treatment. HbA1c level, weight, total daily insulin requirement, and C-peptide, creatinine, and lipids were followed for at least six months. Results: There were 34 patients (14 male, 41.2 %) with a median age of 67 (IQR 63.0-75.5). Six patients (17.6 %) were on chemotherapy and/or steroids (Ch/S). The patients' initial median HbA1c % was 9.3 (IQR 7.6-11.0), c-peptide level was 0.9 (IQR 0.5-2.2) ng/mL, and median total daily insulin dose was 41 IU (IQR 32-53). Six months after the patients were switched to an AID system their HbA1c % decreased to 7.1 (IQR 6.5-8.1), p < 0.001 and c-peptide increased to 1.21 (IQR 0.2-1.7) ng/mL, p = 0.878. Total insulin dose decreased with AID systems [32 IU (IQR 23.9-37.8)), p < 0.001]. There was a decrease in median HbA1c % in patients on Ch/S [8.7 (IQR 7.0-11.5) to 6.9 (IQR 6.3-9.2)] however it didn't reach statistical significance p = 0.225. Total insulin dose also decreased without statistical significance [33 IU (IQR 41-28) to 28 (IQR 23-35), p = 0.173]. The mean time in range (TIR) percent of the patients with AID systems were as follows; <54 mg/dL was 0.5 %, 56-70 mg/dL was 1.3 %, 70-180 mg/dL was 64.8 %, >180 mg/dL was 26.7 % and > 250 mg/dL was 6.7 %. Conclusion: Although AID systems are tested mostly in young type 1 patients our results show that elderly patients with brittle type 2 diabetes also benefit from an AID system. Even in very frail patients such as cancer patients, improvement can be seen.
引用
收藏
页数:5
相关论文
共 33 条
[1]   The consequences of hypoglycaemia [J].
Amiel, Stephanie A. .
DIABETOLOGIA, 2021, 64 (05) :963-970
[2]  
[Anonymous], IDF Diabetes Atlas 2021 | IDF Diabetes Atlas
[3]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[4]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[5]   Diabetes-related morbidity and mortality in a national sample of US elders [J].
Bertoni, AG ;
Anderson, GF ;
Krop, JS ;
Brancati, FL .
DIABETES CARE, 2002, 25 (03) :471-475
[6]   Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trial [J].
Bosi, Emanuele ;
Choudhary, Pratik ;
de Valk, Harold W. ;
Lablanche, Sandrine ;
Castaneda, Javier ;
de Portu, Simona ;
Da Silva, Julien ;
Re, Roseline ;
Vorrink-de Groot, Linda ;
Shin, John ;
Kaufman, Francine R. ;
Cohen, Ohad ;
Bosi, Emanuele ;
Laurenzi, Andrea ;
Caretto, Amelia ;
Choudhary, Pratik ;
Slatterly, David ;
Henderson-Wilson, Marcia ;
Weisnagel, S. John ;
Dube, Marie-Christine ;
Julien, Valerie-Eve ;
Trevisan, Roberto ;
Lepore, Giuseppe ;
Bellante, Rosalia ;
Hramiak, Irene ;
Spaic, Tamara ;
Driscoll, Marsha ;
Borot, Sophie ;
Clergeot, Annie ;
Khiat, Lamia ;
Hammond, Peter ;
Ray, Sutapa ;
Dinning, Laura ;
Tonolo, Giancarlo ;
Manconi, Alberto ;
Ledda, Maura Serena ;
de Valk, Harold ;
de Ranitz, Wendela ;
Silvius, Bianca ;
Wojtusciszyn, Anne ;
Farret, Anne ;
Vriesendorp, Titia ;
Immeker-de Jong, Folkje ;
van der Linden, Joke ;
Brink, Huguette S. ;
Alkemade, Marije ;
Schaepelynck-Belicar, Pauline ;
Galie, Sebastien ;
Treglia, Clemence ;
Lablanche, Sandrine .
LANCET DIABETES & ENDOCRINOLOGY, 2019, 7 (06) :462-472
[7]   Outpatient Safety Assessment of an In-Home Predictive Low-Glucose Suspend System with Type 1 Diabetes Subjects at Elevated Risk of Nocturnal Hypoglycemia [J].
Buckingham, Bruce A. ;
Cameron, Fraser ;
Calhoun, Peter ;
Maahs, David M. ;
Wilson, Darrell M. ;
Chase, H. Peter ;
Bequette, B. Wayne ;
Lum, John ;
Sibayan, Judy ;
Beck, Roy W. ;
Kollman, Craig .
DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (08) :622-627
[8]   Improved Glycemic Outcomes With Medtronic MiniMed Advanced Hybrid Closed-Loop Delivery: Results From a Randomized Crossover Trial Comparing Automated Insulin Delivery With Predictive Low Glucose Suspend in People With Type 1 Diabetes [J].
Collyns, Olivia J. ;
Meier, Renee A. ;
Betts, Zara L. ;
Chan, Denis S. H. ;
Frampton, Chris ;
Frewen, Carla M. ;
Hewapathirana, Niranjala M. ;
Jones, Shirley D. ;
Roy, Anirban ;
Grosman, Benyamin ;
Kurtz, Natalie ;
Shin, John ;
Vigersky, Robert A. ;
Wheeler, Benjamin J. ;
de Bock, Martin I. .
DIABETES CARE, 2021, 44 (04) :969-975
[9]   Prevention of Hypoglycemia by Using Low Glucose Suspend Function in Sensor-Augmented Pump Therapy [J].
Danne, Thomas ;
Kordonouri, Olga ;
Holder, Martin ;
Haberland, Holger ;
Golembowski, Sven ;
Remus, Kerstin ;
Blaesig, Sara ;
Wadien, Tanja ;
Zierow, Susanne ;
Hartmann, Reinhard ;
Thomas, Andreas .
DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (11) :1129-1134
[10]   Diabetes management in chronic kidney disease: a consensus report by the American Diabetes Association (ADA) and Kidney Disease: Improving Global Outcomes (KDIGO) [J].
de Boer, Ian H. ;
Khunti, Kamlesh ;
Sadusky, Tami ;
Tuttle, Katherine R. ;
Neumiller, Joshua J. ;
Rhee, Connie M. ;
Rosas, Sylvia E. ;
Rossing, Peter ;
Bakris, George .
KIDNEY INTERNATIONAL, 2022, 102 (05) :974-989