Neurodegenerative diseases early detection and monitoring system for point-of-care applications

被引:0
作者
Thakur, Rajiv [1 ,2 ]
Saini, Anil Kumar [2 ,3 ]
Taliyan, Rajeev [4 ]
Chaturvedi, Nidhi [1 ,2 ]
机构
[1] CSIR, Cent Elect Engn Res Inst, Semicond Sensors & Microsyst Grp, Pilani 333031, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[3] CSIR, Cent Elect Engn Res Inst, Integrated Circuits & Syst Grp, Pilani 333031, India
[4] Birla Inst Technol & Sci, Dept Pharm, Neuropsychopharmacol Div, Pilani 333031, Rajasthan, India
关键词
Neurodegenerative diseases; GaN HEMT biosensor; Early detection; Handheld system; Biomarkers; FIELD-EFFECT TRANSISTOR; BIOMARKERS; BIOSENSOR; ISFET;
D O I
10.1016/j.microc.2024.112280
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Millions of people worldwide are negatively impacted by a diverse range of brain conditions known as neurodegenerative diseases. The work reports a GaN HEMT-based biosensing system for the early detection and monitoring of neurodegenerative disease biomarkers in clinically relevant concentration ranges. The developed system offers a high sensitivity of 19.40 mu A/pg/ml, 0.52 mA/pg/ml, 0.69 mA/ng/ml, 0.13 mA/pg/ml, 23.66 mu A/ pg/ml, and 23.85 mu A/pg/ml for the detection of UCH-L1, GFAP, S100B, IL-6, A beta, and IFN-gamma respectively. The proposed biofunctionalization assay has an excellent specificity and selectivity, signal-to-noise ratio of 1:16, 1:23, and 1:38 for UCH-L1, GFAP, and S100B detection respectively with a LoD of 0.06 fg/ml. The platform has good repeatability with an average sensitivity of 19.41 mu A/pg/ml, 0.524 mA/pg/ml, and 0.704 mA/ng/ml for UCH-L1, GFAP, and S100B detection respectively. The sensors have a very good shelf-life for a storage time of 35 days with reductions of 1.39 %, 1.72 %, and 2.05 % in sensor response and 2.88 %, 2.76 %, and 2.96 % in sensitivity for UCH-L1, GFAP, and S100B respectively. The coefficient of variation (CV) values for conventional and meander-gated GaN HEMT biosensors were found to be similar to 0.038 and similar to 0.026 respectively. A slight variation of similar to 4.41 % in sensor response when the sensor was reused clearly demonstrates the sensor's reusability. A very high resolution with detection capability in the ultra-low concentration of fg/ml with good linearity and quantifiable sensor response which is a key requirement for early-stage detection of diseases has been observed for sensor design with source-to-drain distance (L-sd) of 10 mu m. Thus, the platform capability and suitability for early detection and prognosis of neurodegenerative disease detection and monitoring have been demonstrated. Further, the system can be imperative in patient screening in clinical, sports, and warfare for CT or MRI scan requirements.
引用
收藏
页数:12
相关论文
共 77 条
  • [61] GaN-based heterostructures for sensor applications
    Stutzmann, M
    Steinhoff, G
    Eickhoff, M
    Ambacher, O
    Nebel, CE
    Schalwig, J
    Neuberger, R
    Müller, G
    [J]. DIAMOND AND RELATED MATERIALS, 2002, 11 (3-6) : 886 - 891
  • [62] Tholen D., 2004, CLSI Document EP17-A24 (34), P1
  • [63] Interleukin-6 electrochemical sensor using poly (o-phenylenediamine)-based molecularly imprinted polymer
    Ting, Wei-Ting
    Wang, Meng-Jiy
    Howlader, Matiar M. R.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2024, 404
  • [64] Simultaneous determination of procalcitonin and interleukin-6 in human serum samples with a point-of-care biosensing device
    Tsounidi, Dimitra
    Tsaousis, Vasileios
    Xenos, Nikolaos
    Kroupis, Christos
    Moutsatsou, Paraskevi
    Christianidis, Vasileios
    Goustouridis, Dimitrios
    Raptis, Ioannis
    Kakabakos, Sotirios
    Petrou, Panagiota
    [J]. TALANTA, 2023, 258
  • [65] Detection of Amyloid-β(1-42) Aggregation With a Nanostructured Electrochemical Sandwich Immunoassay Biosensor
    Wang, Bing-Yu
    Gu, Bien-Chen
    Wang, Gou-Jen
    Yang, Yuan-Han
    Wu, Chia-Che
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [66] Advances in the Application of Transition-Metal Composite Nanozymes in the Field of Biomedicine
    Wang, Huixin
    Cheng, Chunfang
    Zhao, Jingyu
    Han, Fangqin
    Zhao, Guanhui
    Zhang, Yong
    Wang, Yaoguang
    [J]. BIOSENSORS-BASEL, 2024, 14 (01):
  • [67] Self-Luminescent Lanthanide Metal-Organic Frameworks as Signal Probes in Electrochemiluminescence Immunoassay
    Wang, Yaoguang
    Zhao, Guanhui
    Chi, Hong
    Yang, Shenghong
    Niu, Qingfen
    Wu, Dan
    Cao, Wei
    Li, Tianduo
    Ma, Hongmin
    Wei, Qin
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2021, 143 (01) : 504 - 512
  • [68] MoS2@Au as Label for Sensitive Sandwich-Type Immunoassay of Neuron-Specific Enolase
    Wang, Yingying
    Wang, Huixin
    Bai, Yaliang
    Zhao, Guanhui
    Zhang, Nuo
    Zhang, Yong
    Wang, Yaoguang
    Chi, Hong
    [J]. CHEMOSENSORS, 2023, 11 (06)
  • [69] Point-of-Care Devices Using Disease Biomarkers To Diagnose Neurodegenerative Disorders
    Wei, Ting-Yen
    Fu, Yun
    Chang, Kuo-Hsuan
    Lin, Kun-Ju
    Lu, Yu-Jen
    Cheng, Chao-Min
    [J]. TRENDS IN BIOTECHNOLOGY, 2018, 36 (03) : 290 - 303
  • [70] Wfneurology, Number of People Living With Brain Disease Expected to Double by 2050