Evaluation of current patient-based real-time quality control in clinical chemistry testing

被引:0
作者
Cam, Ergin [1 ,3 ]
Topcu, Deniz i. [1 ,4 ]
Kural, Alev [2 ,3 ]
机构
[1] Univ Hlth Sci, Bakirkoy Dr Sadi Konuk Training & Res Hosp, Dept Clin Chem, Dept Biochem, Istanbul, Turkiye
[2] Izmir City Hosp, Minist Hlth, Izmir, Turkiye
[3] Tevfik Saglam Ave 11, TR-34147 Istanbul, Turkiye
[4] Sevket Ince Neighborhood,2148-11 St 1-11, TR-35540 Bayrakli Izmir, Turkiye
关键词
Data Analytics; Laboratory Information System; Laboratory Management; Patient Based Real Time Quality Control; Systematic Error; PERFORMANCE; ALGORITHM;
D O I
10.1016/j.cca.2024.120115
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: To perform simulation studies on patient-based real-time quality control (PBRTQC) for aspartate aminotransferase (AST), iron (Fe), potassium (K), and thyrotropin (thyroid stimulating hormone, TSH) analytes, focusing on optimizing systematic error detection while minimizing data loss. Methods: Clinical laboratory data for the four analytes were analyzed using various truncation methods. Among these methods, truncation limits corresponding to fixed percentiles (e.g., 1st-99th percentiles), reference change value based on between-individual biological variation (RCVg), and truncation limits derived from +/- 3 standard deviations from the mean were included. These exclusion methods were applied using trimming or winsorization techniques, and transformation methods (logarithmic, square root, and Yeo-Johnson transformations) were employed to fit the data to a normal or near-normal distribution. Moving average techniques, such as exponentially weighted moving average (EWMA), were used with various block sizes to evaluate systematic error detection performance. Results: Truncation based on RCVg improved performance for analytes with lower individuality indices-AST, potassium, and TSH-by enabling faster error detection. In contrast, methods either without truncation or with winsorization applied proved to be more effective for Fe. Among the moving average methods, EWMA with smaller block sizes (20 and 30) generally showed superior performance by detecting systematic errors more quickly. Conclusion: RCVg-based truncation improves error detection for analytes with low individuality when combined with PBRTQC methods like EWMA, minimizing data loss. Tailored strategies considering analyte-specific individuality and distribution are essential for optimal error monitoring, warranting further validation in diverse clinical settings.
引用
收藏
页数:8
相关论文
共 20 条
[1]   Patient-Based Real-Time Quality Control: Review and Recommendations [J].
Badrick, Tony ;
Bietenbeck, Andreas ;
Cervinski, Mark A. ;
Katayev, Alex ;
van Rossum, Huub H. ;
Loh, Tze Ping .
CLINICAL CHEMISTRY, 2019, 65 (08) :962-971
[2]   Understanding Patient-Based Real-Time Quality Control Using Simulation Modeling [J].
Bietenbeck, Andreas ;
Cervinski, Mark A. ;
Katayev, Alex ;
Loh, Tze Ping ;
van Rossum, Huub H. ;
Badrick, Tony .
CLINICAL CHEMISTRY, 2020, 66 (08) :1072-1083
[3]   Truncation limits of patient-based real-time quality control: a new model derived from between-subject biological variations [J].
Coskun, Abdurrahman ;
Cavusoglu, Coskun ;
Serteser, Mustafa ;
Serdar, Muhittin ;
Kilercik, Meltem ;
Aksungar, Fehime ;
Unsal, Ibrahim .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (04) :E133-E136
[4]   Assessment of patient-based real-time quality control algorithm performance on different types of analytical error [J].
Duan, Xincen ;
Wang, Beili ;
Zhu, Jing ;
Shao, Wenqi ;
Wang, Hao ;
Shen, Junfei ;
Wu, Wenhao ;
Jiang, Wenhai ;
Yiu, Kwok Leung ;
Pan, Baishen ;
Guo, Wei .
CLINICA CHIMICA ACTA, 2020, 511 :329-335
[5]   Changing the paradigm of laboratory quality control through implementation of real-time test results monitoring: For patients by patients [J].
Fleming, James K. ;
Katayev, Alexander .
CLINICAL BIOCHEMISTRY, 2015, 48 (7-8) :508-513
[6]   Observed, unknown distributions of clinical chemical quantities should be considered to be log-normal: a proposal [J].
Haeckel, Rainer ;
Wosniok, Werner .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) :1393-1396
[7]   A study of the moving rate of positive results for use in a patient-based real-time quality control program on a procalcitonin point-of-care testing analyzer [J].
He, Yili ;
Gu, Daqing ;
Kong, Xiangzhi ;
Feng, Zhiqiang ;
Lin, Weishang ;
Cai, Yunfeng .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (04)
[8]   Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium [J].
Li, Yuanyuan ;
Yu, Qian ;
Zhang, Xiaoyan ;
Chen, Xiaoling .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (10)
[9]   Recommendation for performance verification of patient-based real-time quality control [J].
Loh, Tze Ping ;
Bietenbeck, Andreas ;
Cervinski, Mark A. ;
van Rossum, Huub H. ;
Katayev, Alex ;
Badrick, Tony .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (08) :1205-1213
[10]   Recommendations for laboratory informatics specifications needed for the application of patient-based real time quality control [J].
Loh, Tze Ping ;
Cervinski, Mark A. ;
Katayev, Alex ;
Bietenbeck, Andreas ;
van Rossum, Huub ;
Badrick, Tony .
CLINICA CHIMICA ACTA, 2019, 495 :625-629