Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Parameters and Their Associated Factors in Cynomolgus Macaques

被引:0
|
作者
Zhang, Yuan [1 ]
Ye, Guitong [1 ]
Chen, Kezhe [1 ]
Huang, Shaofen [1 ]
Xie, Rui [1 ]
Chen, Jianqi [1 ]
Liu, Wei [2 ]
Wang, Zhiwei [2 ]
Luo, Ruiyu [1 ]
Zhan, Jinan [1 ]
Zhuo, Yehong [1 ]
Li, Yiqing [1 ]
Zhu, Yingting [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, 7 Jinsui Rd, Guangzhou 510623, Peoples R China
[2] Huazhen Biosci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
cynomolgus macaques; retinal nerve fiber layer (RNFL) thickness; refractive errors; axial length (AL); OPTICAL COHERENCE TOMOGRAPHY; AXIAL LENGTH; GLAUCOMA-PROGRESSION; CHINESE CHILDREN; THICKNESS; MYOPIA; EYES; AGE; HEAD; PROFILE;
D O I
10.1167/iovs.65.11.14
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The purpose of this study was to define the normal range of peripapillary retinal nerve fiber layer (pRNFL), macular ganglion cell layer (mGCL), and macular inner plexiform layer (mIPL) thickness in cynomolgus macaques, and explore their inter-relationship and correlation with age, refractive errors, and axial length (AL). METHODS. In this cross-sectional study, we measured biometric and refractive parameters, and pRNFL/mGCL/mIPL thickness in 357 healthy cynomolgus macaques. Monkeys were divided into groups by age and spherical equivalent (SE). Correlation and regression analyses were used to explore the relationship between pRNFL and mGCL/mIPL thickness, and their correlation with the above parameters. RESULTS. The mean age, SE, and AL were 14.46 +/- 6.70 years, -0.96 +/- 3.23 diopters (D), and 18.39 +/- 1.02 mm, respectively. The mean global pRNFL thickness was 95.06 +/- 9.42 mu m (range = 54-116 mu m), with highest values in the inferior quadrant, followed by the superior, temporal, and nasal quadrants (P < 0.001). Temporal pRNFL thickness correlated positively with age (r = 0.218, P < 0.001) and AL (r = 0.364, P < 0.001), and negatively with SE (r = -0.270, P < 0.001). In other quadrants, pRNFL thickness correlated negatively with age and AL, but positively with SE. In the multivariable linear regression model, adjusted for sex and AL, age (9 = -0.350, P < 0.001), and SE (9 = 0.206, P < 0.001) showed significant associations with global pRNFL thickness. After adjusting for age, sex, SE, and AL, pRNFL thickness positively correlated with mGCL (9 = 0.433, P < 0.001) and mIPL thickness (9 = 0.465, P < 0.001). CONCLUSIONS. The pRNFL/mGCL/mIPL thickness distribution and relationship with age, AL, and SE in cynomolgus macaques were highly comparable to those in humans, suggesting that cynomolgus monkeys are valuable animal models in ophthalmic research.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Retinal ganglion cell-inner plexiform and nerve fiber layers in neuromyelitis optica
    Hu, Sai-Jing
    Lu, Pei-Rong
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (01) : 89 - 93
  • [42] Macular ganglion cell-inner plexiform layer thickness for detection of early retinal toxicity of hydroxychloroquine
    Kan, Emrah
    Yakar, Konuralp
    Demirag, Mehmet Derya
    Gok, Mustafa
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1635 - 1640
  • [43] The thickness of the retinal nerve fiber layer, macula, and ganglion cell-inner plexiform layer in people with drug-resistant epilepsy
    Chen, Yujie
    Xiong, Weixi
    Lu, Lu
    Wu, Xintong
    Cao, Le
    Chen, Jiani
    Xiao, Yingfeng
    Sander, Josemir W.
    Wu, Bo
    Zhou, Dong
    EPILEPSIA OPEN, 2024, 9 (05) : 1783 - 1792
  • [44] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness, Functional Subzones, and Macular Ganglion Cell-Inner Plexiform Layer in Differentiating Patients With Mild, Moderate, and Severe Open-angle Glaucoma
    Huo, Yan Jiao
    Thomas, Ravi
    Li, Lei
    Cao, Kai
    Wang, Huai Zhou
    Wang, Ning Li
    JOURNAL OF GLAUCOMA, 2020, 29 (09) : 761 - 766
  • [45] Evaluation of the Macular Ganglion Cell-Inner Plexiform Layer and the Circumpapillary Retinal Nerve Fiber Layer in Early to Severe Stages of Glaucoma: Correlation with Central Visual Function and Visual Field Indexes
    Pilar Bambo, Maria
    Guerri, Noemi
    Ferrandez, Blanca
    Cameo, Beatriz
    Fuertes, Isabel
    Polo, Vicente
    Garcia-Martin, Elena
    OPHTHALMIC RESEARCH, 2017, 57 (04) : 216 - 223
  • [46] Decreases in retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in schizophrenia, relation to insight: a controlled study
    Delibas, Dursun Hakan
    Karti, Omer
    Erdogan, Esin
    Sahin, Tuba
    Bilgic, Omer
    Erol, Almila
    ANADOLU PSIKIYATRI DERGISI-ANATOLIAN JOURNAL OF PSYCHIATRY, 2018, 19 (03): : 264 - 273
  • [47] Macular Ganglion Cell Inner Plexiform Layer Thickness in Glaucomatous Eyes with Localized Retinal Nerve Fiber Layer Defects
    Zhang, Chunwei
    Tatham, Andrew J.
    Abe, Ricardo Y.
    Hammel, Na'ama
    Belghith, Akram
    Weinreb, Robert N.
    Medeiros, Felipe A.
    Liebmann, Jeffrey M.
    Girkin, Christopher A.
    Zangwill, Linda M.
    PLOS ONE, 2016, 11 (08):
  • [48] A comparison of false positives in retinal nerve fiber layer, optic nerve head and macular ganglion cell-inner plexiform layer from two spectral-domain optical coherence tomography devices
    Leal-Fonseca, Marina
    Rebolleda, Gema
    Oblanca, Noelia
    Moreno-Montanes, Javier
    Munoz-Negrete, Francisco J.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (02) : 321 - 330
  • [49] Macular Inner Plexiform and Retinal Nerve Fiber Layer Thickness in Glaucoma
    Jung, Hyun-Ho
    Sung, Mi-Sun
    Heo, Hwan
    Park, Sang-Woo
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (11) : 1320 - 1327
  • [50] Retinal nerve fibre layer/ganglion cell-inner plexiform layer thickness ratio in patients with systemic hypertension
    Lee, Woo Hyuk
    Lee, Min-Woo
    Lim, Hyung-Bin
    Kim, Min-Su
    Ryu, Cheon Kuk
    Han, Yong-Seop
    Kim, Jung-Yeul
    ACTA OPHTHALMOLOGICA, 2022, 100 (01) : E150 - E156