Lateral behavior of columns with high-strength steel coiled strip confinement

被引:0
作者
Barbachyn, Steven M. [1 ,2 ]
Oh, Shane [3 ]
Pearson, Lily A. [3 ,4 ]
Thrall, Ashley P. [5 ]
Weldon, Brad D. [6 ]
Kurama, Yahya C. [2 ]
机构
[1] Univ Minnesota Minneapolis, Galambos & MAST Struct Engn Labs, Minneapolis, MN 55455 USA
[2] Univ Notre Dame Notre Dame, Dept Civil & Environm Engn & Earth Sci, Notre Dame, IN USA
[3] Univ Notre Dame, Notre Dame, IN USA
[4] Frost Engn & Consulting, Mishawaka, IN USA
[5] Univ Notre Dame, Dept Civil & Environm Engn & Earth Sci, Struct Engn, Notre Dame, IN USA
[6] Univ Notre Dame, Civil Engn, Notre Dame, IN USA
来源
PCI JOURNAL | 2025年 / 70卷 / 01期
关键词
Column; confinement; high-strength steel; lateral load; reinforced concrete; strip reinforcement;
D O I
10.15554/pcij70.1-01
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the experimental investigation of the behavior of square reinforced concrete columns ksi [690 MPa]) steel coiled strips as embedded confinement reinforcement under Bodyreversed-cyclictext lateral loading and constant axial compression load. Six full-scale specimens (20 x 20 in. Keywords[508 x 508 mm] cross section) with the following variations were tested: confinement type (strip or reinforcingBody bar),textlayout(hoops and ties, spirals), and reinforcement ratios. The strip-confined specimens had similar peakReviewstrengths aspolicyaspecimenconfined by reinforcing bar ties, and this strength exceeded analytical predicBdytions.textThestiffness of the strip-confinedspecimens was greater than the reinforcing-bar-confined specimen. InReaderaccordance withthecommentsAmericanConcrete Institute's Acceptance Criteria for Moment Frames Based on Body Structural text Testing (T1.1-01),all specimens met the criterion that the lateral load at 3.5% drift was not below 75% of the peak. Strip-confined specimens demonstrated improved residual strength behavior relative to the reinforcing-bar-confined specimen. Overall, the study demonstrated the promise of steel strip confinement for reinforced concrete columns in seismic regions.
引用
收藏
页码:38 / 57
页数:20
相关论文
共 14 条
[1]  
ACI (American Concrete Institute), 2001, Acceptance criteria for moment frames based on structural testing
[2]  
[Anonymous], 2018, STANDARD TEST METHOD, DOI [DOI 10.1520/C0039_C0039M-21, 10.1520/C0039_C0039M-21]
[3]  
[Anonymous], 2008, 318 ACI
[4]  
ASTM International, 2022, C469C469M22 ASTM INT
[5]  
ASTM International, 2024, ASTM A1035/A1035M-24
[6]  
ASTM International, 2022, ASTM A615/A615M-22
[7]  
ASTM International, 2017, ASTM E111-17
[8]  
ASTM International, 2022, ASTM A370-22
[9]   Axial load behavior of reinforced concrete columns with high-strength steel coiled strips as confinement [J].
Barbachyn, Steven M. ;
O'Donnell, Anne ;
Thrall, Ashley P. ;
Kurama, Yahya C. .
PCI JOURNAL, 2023, 68 (05) :21-41
[10]  
Kidder F. E., 1911, Building Construction and Superintendence