Research on design and optimization method for a supercritical CO2 centrifugal compressor for gas-cooled micro reactors

被引:1
作者
Lu, Daogang [1 ,2 ]
Liu, Minglei [1 ,2 ]
Wang, Xiaotian [1 ,2 ]
Cao, Qiong [1 ,2 ]
Liu, Yu [1 ,2 ]
Li, Jinjian [1 ,2 ]
机构
[1] North China Elect Power Univ, Sch Nucl Sci & Engn, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Beijing Key Lab Pass Safety Technol Nucl Energy, Beijing 102206, Peoples R China
关键词
Supercritical carbon dioxide; Centrifugal compressor; Orthogonal test; Numerical simulation; Blade wrap angle; Tip clearance; HEAT-TRANSFER; PERFORMANCE; CYCLE;
D O I
10.1016/j.pnucene.2025.105630
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The supercritical carbon dioxide(sCO2) Brayton cycle shows significant advantages over the steam Rankine cycle due to its compact size, minimal space requirements, and high energy density. It has become a highly promising research direction in the field of fourth-generation nuclear reactors. The compressor, a core component of this cycle, plays a crucial role in ensuring system efficiency and stable operation. Among various typical compressors, the centrifugal compressor stands out as an excellent choice for the sCO2Brayton cycle due to its compact size, ease of manufacturing and installation, superior performance, and efficient operation. The conventional onedimensional (1D) centrifugal compressor design does not accurately reflect the flow and compression process especially near the critical point, while the conventional three-dimensional (3D) design lacks boundary conditions and geometric parameter selection basis, therefore, this paper proposes an effective combination method of 1D and 3D design. First, this paper introduces the orthogonal test method to determine the primary parameters for the 1D design of sCO2centrifugal compressors, which shows an effective reduction in workload. Next, after validating the design method, the design and optimization of a 300 kW sCO2 compressor in 3D has been carried out. Performance curves are obtained under different blade wrap angles and tip clearances. The optimal values of blade wrap angle and tip clearance of the compressor are identified using the sensitivity analysis. Finally, the performance of the optimized centrifugal compressor has been investigated through numerical simulation under several rotational speeds, inlet pressures, and inlet temperatures around the set operating conditions. This research holds significant implications for the design of sCO2centrifugal compressors in gas-cooled micro reactors.
引用
收藏
页数:14
相关论文
共 26 条
[1]  
Balje O.E., 1952, T AM SOC MECH ENG, V74, P451, DOI DOI 10.1115/1.4015814
[2]  
Brenes BenjaminMonge, 2014, THESIS U SEVILLA
[3]   A COMPUTATIONAL GEOMETRY FOR THE BLADES AND INTERNAL FLOW CHANNELS OF CENTRIFUGAL COMPRESSORS [J].
CASEY, MV .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1983, 105 (02) :288-295
[4]   Off-design performance and control strategies of sCO2 recompression power systems considering compressor operating safety [J].
Chang, Zhiyuan ;
Zhao, Yu ;
Zhao, Yuanyang ;
Liu, Guangbin ;
Yang, Qichao ;
Li, Liansheng .
APPLIED THERMAL ENGINEERING, 2023, 232
[5]  
Cho S.K., 2019, APPL SCI-BASEL, V9, P4057, DOI [10.3390/app9194057, DOI 10.3390/app9194057]
[6]   High-performance supercritical carbon dioxide cycle for next-generation nuclear reactors [J].
Dostal, Vaclav ;
Hejzlar, Pavel ;
Driscoll, Michael J. .
NUCLEAR TECHNOLOGY, 2006, 154 (03) :265-282
[7]   One-dimensional optimisation design and off-design operation strategy of centrifugal compressor for supercritical carbon dioxide Brayton cycle [J].
Du, Yadong ;
Yang, Ce ;
Wang, Haimei ;
Hu, Chenxing .
APPLIED THERMAL ENGINEERING, 2021, 196
[8]   Optimal design of supercritical CO2 power cycle for next generation nuclear power conversion systems [J].
Guo, Zhangpeng ;
Zhao, Yang ;
Zhu, Yaoxuan ;
Niu, Fenglei ;
Lu, Daogang .
PROGRESS IN NUCLEAR ENERGY, 2018, 108 :111-121
[9]  
Jansen W., 1970, Inst. Mech. Eng, Internal Aerodynamics
[10]   The performance of a transcritical CO2 cycle with an internal heat exchanger for hot water heating [J].
Kim, SG ;
Kim, YJ ;
Lee, G ;
Kim, MS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (07) :1064-1072