Field test and long-term heat extraction performance evaluation of the deep U-type borehole heat exchanger system

被引:1
作者
Cai, Wanlong [1 ]
Wang, Fenghao [1 ]
Zhang, Yuping [2 ]
Jiang, Jinghua [1 ]
Wang, Qiuwang [3 ]
Shao, Haibing [4 ]
Kolditz, Olaf [4 ,5 ]
Nagel, Thomas [4 ,6 ]
Chen, Chaofan [4 ,6 ,7 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Peoples R China
[2] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Utili, Xian 710049, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[4] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[5] Tech Univ Dresden, Fac Environm Sci, D-01069 Dresden, Germany
[6] Tech Univ Bergakad Freiberg, Geotech Inst, D-09599 Freiberg, Germany
[7] China Univ Min & Technol Beijing, Sch Energy & Min Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Deep U-type Borehole Heat Exchanger (DUBHE); Field test; Long-term performance; System optimization; Eavor-loop technology; OpenGeoSys; NUMERICAL-ANALYSIS; BEND PIPE;
D O I
10.1016/j.renene.2024.122171
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concept of the deep U-type borehole heat exchanger (DUBHE) has been proposed and implemented in recent years to achieve higher heat extraction capacity and efficiency. Given the substantial initial investment required for implementation, it becomes imperative to quantitatively assess the long-term thermo-technoeconomic performance of the DUBHE system. In this study, the pilot DUBHE project in Xi'an, China, is first introduced in detail, along with 60-day in-situ monitoring data. The monitoring data are used for the validation of a heterogeneous 3D numerical model that is established in OpenGeoSys (OGS) software. Based on the validated model, a series of extended scenarios of the DUBHE system are simulated to show that the maximum sustainable heat extraction rate of the pilot DUBHE system is around 480 kW. The heat extraction capacity of the DUBHE can be significantly improved by a larger depth rather than a longer horizontal length. The thermally affected distance extends more than 35 m away from the borehole. The techno-economic analysis shows that the lowest value of the Levelized Cost of Energy (LCOE) of the DUBHE system is 0.584 Yuan/kWh, which corresponds to the scenario with a vertical depth of 2800 m and a horizontal length of 600 m.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Thermal Performance Analysis on the Seasonal Heat Storage by Deep Borehole Heat Exchanger with the Extended Finite Line Source Model
    Qin, Xiangxi
    Zhao, Yazhou
    Dai, Chengjun
    Wei, Jian
    Xue, Dahai
    ENERGIES, 2022, 15 (22)
  • [42] Repurposing a Geothermal Exploration Well as a Deep Borehole Heat Exchanger: Understanding Long-Term Effects of Lithological Layering, Flow Direction, and Circulation Flow Rate
    Kolo, Isa
    Brown, Christopher S.
    Falcone, Gioia
    Banks, David
    SUSTAINABILITY, 2023, 15 (05)
  • [43] Can deep borehole heat exchangers operate stably in long-term operation? Simulation analysis and design method
    Deng, Jiewen
    Qiang, Wenbo
    Peng, Chenwei
    Wei, Qingpeng
    Cai, Wanlong
    Zhang, Hui
    JOURNAL OF BUILDING ENGINEERING, 2022, 62
  • [44] Numerical investigation of the deep borehole heat exchanger in medium-depth geothermal heat pump system for building space heating
    Wang, Xiaoyan
    Su, Yanmin
    Liu, Guang
    Ni, Long
    ENERGY AND BUILDINGS, 2024, 304
  • [45] Field test and geologic-thermal-economic analysis of medium-depth borehole heat exchanger
    Dong, Shihao
    Yu, Yuelong
    Li, Bingxue
    Ni, Long
    JOURNAL OF CLEANER PRODUCTION, 2024, 447
  • [46] Influencing factor analysis and optimization of heat extraction performance of moderately deep coaxial borehole heat exchangers in northern Shaanxi, China
    Zou H.
    Li Y.
    Zhang L.
    Hui P.
    Liu H.
    Shen F.
    Wang F.
    Meitiandizhi Yu Kantan/Coal Geology and Exploration, 2024, 52 (01): : 1 - 7
  • [47] A comprehensive investigation on U-tube ground heat exchanger performance considering insulation layer in deep geothermal system
    Xu, Ningning
    He, Miao
    Xu, Mingbiao
    Chen, Huan
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [48] System design and long-term field test for a novel multi-mode heating tower heat pump system in cold regions
    Zhao, Shanguo
    Zhang, Xiaosong
    Liang, Caihua
    Huang, Shifang
    SUSTAINABLE CITIES AND SOCIETY, 2023, 89
  • [49] Comparison of the experimental and numerical results of coaxial-type and U-type deep-buried pipes' heat transfer performances
    Li, Chao
    Jiang, Chao
    Guan, Yanling
    Chen, Hao
    Yang, Ruitao
    Wan, Rong
    Shen, Lu
    RENEWABLE ENERGY, 2023, 210 : 95 - 106
  • [50] Heat extraction from hot dry rock by super-long gravity heat pipe: A field test
    Huang, Wenbo
    Cen, Jiwen
    Chen, Juanwen
    Cao, Wenjiong
    Li, Zhibin
    Li, Feng
    Jiang, Fangming
    ENERGY, 2022, 247