Influence of mechanical anchors on bond performance of fiber fabric-steel joints

被引:1
作者
Zhao, Zhongwei [1 ,2 ]
Jin, Zeyuan [2 ]
机构
[1] Liaoning Tech Univ, Ordos Inst, Ordos 017004, Peoples R China
[2] Liaoning Tech Univ, Sch Civil Engn, Fuxin 123000, Peoples R China
关键词
Bond-slip behavior; Carbon fiber fabric; Steel structure reinforcement; Mechanical anchors; FRP; BEHAVIOR; COMPOSITES;
D O I
10.1016/j.jcsr.2024.109057
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes an experimental model for anchor reinforcement and conducts uniaxial static tensile tests. The influence of anchor reinforcement on the failure mode of specimens is revealed. This includes the effects of bond length, number of layers, and types of fiber fabric under anchor reinforcement on the ultimate bearing capacity and bond-slip curve. The results demonstrate that anchors can effectively increase the ultimate bearing capacity of the test specimens. There are differences in bond-slip behavior between the anchors near the free end and the joint end. Higher stresses are experienced near the joint end. The use of anchor reinforcement can significantly enhance the load-bearing capacity of multi-layer carbon fiber specimens. Increasing the number of anchors and reducing the distance between the anchor and the joint end can further improve the stiffness of the specimens. A finite element model is established using ANSYS, which agrees well with the experimental results and parameterized analysis results reveal a linear increase in load-bearing capacity and stiffness with higher anchor bolt preload, achieving an 84.42 % increase at 11kN. Increased preload enhances friction at the carbon fiber-steel interface, reducing deformation. Similarly, expanding anchor width from 9 mm to 39 mm improves load-bearing capacity by 54.28 %, with larger anchors significantly boosting stiffness and bonding performance, which can be used to predict the mechanical properties of fiber fabric-steel reinforced by anchors.
引用
收藏
页数:17
相关论文
共 32 条
[1]   Derivation of the bond-slip characteristics for FRP plated steel members [J].
Akbar, Ibrisam ;
Oehlers, Deric John ;
Ali, M. S. Mohamed .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (8-9) :1047-1056
[2]  
Cheng Jiangmin, 2012, Steel Struct., V27, P1
[3]   Seismic behaviors of CFT-column frame-four-corner bolted connected buckling-restrained steel plate shear walls using ALC/RAC panels [J].
Du, Yansheng ;
Amer, Mohammed ;
Chen, Zhihua ;
Al-Haaj, Mohammed ;
Huang, Jin .
THIN-WALLED STRUCTURES, 2024, 195
[4]   Experimental and theoretical investigation of FRP-steel composite plate under cyclic tensile loading [J].
Du, Yansheng ;
Gao, Dinghui ;
Chen, Zhihua ;
Yan, Jia-Bao ;
Jia, Peihai ;
Dong, Shaohua .
THIN-WALLED STRUCTURES, 2023, 183
[5]   Behaviors of FRP confined rectangular concrete-filled thin-walled steel tubular stub columns using high-strength materials under axial load [J].
Du, Yansheng ;
Gao, Dinghui ;
Chen, Zhihua ;
Zheng, Zihan ;
Wang, Xiaodun .
COMPOSITE STRUCTURES, 2022, 280
[6]   Fatigue strengthening of damaged metallic beams using prestressed unbonded and bonded CFRP plates [J].
Ghafoori, E. ;
Motavalli, M. ;
Botsis, J. ;
Herwig, A. ;
Galli, M. .
INTERNATIONAL JOURNAL OF FATIGUE, 2012, 44 :303-315
[7]  
Halliwell S, 2004, P I CIVIL ENG-STR B, V157, P99
[8]   Effects of moisture on the long-term performance of adhesively bonded FRP/steel joints used in bridges [J].
Heshmati, Mohsen ;
Haghani, Reza ;
Al-Emrani, Mohammad .
COMPOSITES PART B-ENGINEERING, 2016, 92 :447-462
[9]   A review of the present and future utilisation of FRP composites in the civil infrastructure with reference to their important in-service properties [J].
Hollaway, L. C. .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (12) :2419-2445
[10]   Effect of carbon nanotube modified epoxy adhesive on CFRP-to-steel interface [J].
Korayem, Asghar H. ;
Li, Chen Yang ;
Zhang, Qian Hui ;
Zhao, Xiao Ling ;
Duan, Wen Hui .
COMPOSITES PART B-ENGINEERING, 2015, 79 :95-104