Dynamic variation of tibiofemoral compression force during total knee arthroplasty: Implications for soft tissue balance and functional outcomes

被引:0
作者
Okamoto, Yoshinori [1 ]
Okayoshi, Tomohiro [1 ]
Wakama, Hitoshi [1 ]
Saika, Takafumi [1 ]
Otsuki, Shuhei [1 ]
机构
[1] Osaka Med & Pharmaceut Univ, Dept Orthoped Surg, 2-7 Daigaku Machi, Takatsuki 5698686, Japan
关键词
Compressive force; Dynamic analysis; Patient-reported outcomes; Total knee arthroplasty; ALIGNMENT; FLEXION;
D O I
10.1016/j.knee.2024.11.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Achieving precise alignment and soft tissue balance is crucial for optimal total knee arthroplasty (TKA) outcomes. We aimed to explore how tibiofemoral compression force (TFCF) varies with knee flexion and its correlation with functional outcomes. Methods: This prospective study included 60 patients undergoing cruciate-retaining TKA (FINE Total Knee System). Sensor-equipped trial inserts were used to measure the TFCF at 15 degrees intervals, from full extension to 90 degrees flexion. Patients were classified into anterior and posterior force groups based on whether the medial TFCF was higher in the anterior than in the posterior region at 60 degrees flexion. The 2-year outcomes were assessed using the Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS-JR). Results: The total TFCF increased from 0 degrees to 60 degrees flexion and then decreased. The medial compressive forces were consistently higher than lateral forces. Anteromedial TFCF differed significantly between the anterior and posterior force groups at 60 degrees, 75 degrees, and 90 degrees flexion. KOOS-JR scores showed a significant interaction between force type and time, with greater improvements in the anterior force group. Anteromedial TFCF at 60 degrees flexion and KOOS-JR correlated significantly (R = 0.574). Conclusion: Evaluating TFCF at multiple knee flexion angles provides valuable insights into optimising outcomes in TKA. TFCF variations, especially in the anteromedial compartment, considerably impact functional outcomes. Dynamic TFCF measurements during TKA may enhance soft tissue balance and improve outcomes. Further research is needed to validate these findings in diverse populations and with long-term follow ups. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:49 / 61
页数:13
相关论文
共 50 条
  • [31] Tibiofemoral compressive force during downhill walking in patients with primary total knee arthroplasty: A statistical parametric mapping approach
    Thorsen, Tanner
    Wen, Chen
    Porter, Jared
    Reinbolt, Jeffery
    Weinhandl, Joshua T.
    Zhang, Songning
    CLINICAL BIOMECHANICS, 2023, 102
  • [32] Influence of Intraoperative Soft Tissue Balance on Postoperative Active Knee Extension in Posterior-Stabilized Total Knee Arthroplasty
    Nagai, Kanto
    Muratsu, Hirotsugu
    Matsumoto, Tomoyuki
    Takahara, Shunsuke
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    JOURNAL OF ARTHROPLASTY, 2015, 30 (07) : 1155 - 1159
  • [33] Intraoperative Soft Tissue Balance/Kinematics and Clinical Evaluation of Modified Kinematically versus Mechanically Aligned Total Knee Arthroplasty
    Matsumoto, Tomoyuki
    Takayama, Koji
    Ishida, Kazunari
    Kuroda, Yuichi
    Tsubosaka, Masanori
    Muratsu, Hirotsugu
    Hayashi, Shinya
    Hashimoto, Shingo
    Matsushita, Takehiko
    Niikura, Takahiro
    Kuroda, Ryosuke
    JOURNAL OF KNEE SURGERY, 2020, 33 (08) : 777 - 784
  • [34] Comparison of intraoperative soft tissue balance measurement between two tensor systems in total knee arthroplasty
    Takashima, Yoshinori
    Takayama, Koji
    Ishida, Kazunari
    Muratsu, Hirotsugu
    Matsushita, Takehiko
    Niikura, Takahiro
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    KNEE, 2020, 27 (03) : 1071 - 1077
  • [35] The influence of intraoperative soft tissue balance on patellar pressure in posterior-stabilized total knee arthroplasty
    Matsumoto, Tomoyuki
    Shibanuma, Nao
    Takayama, Koji
    Sasaki, Hiroshi
    Ishida, Kazunari
    Matsushita, Takehiko
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    KNEE, 2016, 23 (03) : 540 - 544
  • [36] Intraoperative pressure sensors improve soft-tissue balance but not clinical outcomes in total knee arthroplasty: a multicentre randomized controlled trial
    MacDessi, S. J.
    Wood, J. A.
    Diwan, A.
    Harris, I. A.
    BONE & JOINT JOURNAL, 2022, 104B (05) : 604 - 612
  • [37] Soft Tissue Coverage of Complex Periprosthetic Defects in Patients With Total Knee Arthroplasty: Analysis of Factors That Influence Reconstructive and Functional Outcomes
    Economides, James M.
    DeFazio, Michael, V
    Golshani, Kayvon
    Cinque, Mark
    Anghel, Ersilia L.
    Lakhiani, Chrisovalantis
    Hung, Rex
    Attinger, Christopher E.
    Evans, Karen K.
    WOUNDS-A COMPENDIUM OF CLINICAL RESEARCH AND PRACTICE, 2018, 30 (10): : 283 - +
  • [38] Intraoperative Soft Tissue Balance Reflects Minimum 5-Year Midterm Outcomes in Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty
    Matsumoto, Tomoyuki
    Muratsu, Hirotsugu
    Kubo, Seiji
    Matsushita, Takehiko
    Kurosaka, Masahiro
    Kuroda, Ryosuke
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09) : 1723 - 1730
  • [39] An electronic force sensor accurately detects increased but not decreased soft tissue tension in total knee arthroplasty
    Kuriyama, Shinichi
    Nishitani, Kohei
    Nakamura, Shinichiro
    Matsuda, Shuichi
    KNEE, 2023, 42 : 210 - 219
  • [40] Insertion of a spacer block translates the tibia anteriorly during evaluation of soft tissue balance in cruciate-retaining total knee arthroplasty
    Nitta, Akihiro
    Wada, Keizo
    Hamada, Daisuke
    Oba, Koichi
    Mikami, Hiroshi
    Sairyo, Koichi
    KNEE, 2023, 42 : 125 - 129