Real-Time Biomarkers of Liver Graft Quality in Hypothermic Oxygenated Machine Perfusion

被引:0
|
作者
Zhylko, Andriy [1 ,2 ]
Morawski, Marcin [1 ,2 ]
Rykowski, Pawel [1 ,2 ]
Krasnodebski, Maciej [1 ]
Wyporski, Anya [1 ]
Borkowski, Jan [1 ]
Zhylko, Dmytro [3 ]
Kobryn, Konrad [1 ]
Stankiewicz, Rafal [1 ]
Stypulkowski, Jan [1 ,2 ]
Holowko, Waclaw [1 ]
Patkowski, Waldemar [1 ]
Wroblewski, Tadeusz [1 ]
Szczepankiewicz, Benedykt [4 ]
Gornicka, Barbara [4 ]
Mielczarek-Puta, Magdalena [5 ]
Struga, Marta [5 ]
Krawczyk, Marek [1 ]
Grat, Michal [1 ,2 ]
机构
[1] Med Univ Warsaw, Dept Gen Transplant & Liver Surg, Banacha 1a, PL-02097 Warsaw, Poland
[2] Med Univ Warsaw, Doctoral Sch, PL-02091 Warsaw, Poland
[3] New York Univ Abu Dhabi, Comp Engn Div, POB 129188, Abu Dhabi, U Arab Emirates
[4] Med Univ Warsaw, Dept Pathol, PL-02004 Warsaw, Poland
[5] Med Univ Warsaw, Dept Biochem, PL-02097 Warsaw, Poland
关键词
allograft function; biomarkers; liver transplantation; machine perfusion; EARLY ALLOGRAFT DYSFUNCTION; STATIC COLD-STORAGE; TRANSPLANTATION; DEATH; PRESERVATION; DONATION; REPERFUSION; CRITERIA; INJURY; METABOLOMICS;
D O I
10.3390/jcm14020471
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Hypothermic oxygenated machine perfusion has emerged as a strategy to alleviate ischemic-reperfusion injury in liver grafts. Nevertheless, there is limited data on the effectiveness of hypothermic liver perfusion in evaluating organ quality. This study aimed to introduce a readily accessible real-time predictive biomarker measured in machine perfusate for post-transplant liver graft function. Methods: The study evaluated perfusate analytes over a 90-day postoperative period in 26 patients randomly assigned to receive a liver graft following dual hypothermic machine perfusion in a prospective randomized controlled trial. Machine perfusion was consistently conducted end-ischemically for at least 120 min, with real-time perfusate assessment at 30-min intervals. Graft functionality was assessed using established metrics, including Early Allograft Dysfunction (EAD). Results: Perfusate lactate concentration after 120 min of machine perfusion demonstrated significant predictive value for EAD (AUC ROC: 0.841, p = 0.009). Additionally, it correlated with post-transplant peak transaminase levels and extended hospital stays. Subgroup analysis revealed significantly higher lactate accumulation in livers with post-transplant EAD. Conclusions: Liver graft quality can be effectively assessed during hypothermic machine perfusion using simple perfusate lactate measurements. The reliability and accessibility of this evaluation support its potential integration into diverse transplant centers.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Novel Real-time Prediction of Liver Graft Function During Hypothermic Oxygenated Machine Perfusion Before Liver Transplantation
    Muller, Xavier
    Schlegel, Andrea
    Kron, Philipp
    Eshmuminov, Dilmurodjon
    Wuerdinger, Michael
    Meierhofer, David
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    ANNALS OF SURGERY, 2019, 270 (05) : 783 - 790
  • [2] Hypothermic Oxygenated Machine Perfusion of Liver Grafts: Preliminary Experience in a Single Center
    Nicolaescu, Diana
    Barcu, Alexandru
    Verdea, Cosmin
    Picu, Catalina Nausica
    Zamfir, Radu
    Hrehoret, Doina
    Pantis, Carmen
    Tomescu, Dana
    Herlea, Vlad
    Brasoveanu, Vlad
    Popescu, Irinel
    Botea, Florin
    CHIRURGIA, 2021, 116 (04) : 451 - 465
  • [3] Routine End-ischemic Hypothermic Oxygenated Machine Perfusion in Liver Transplantation From Donors After Brain Death A Randomized Controlled Trial
    Grat, Michal
    Morawski, Marcin
    Zhylko, Andriy
    Rykowski, Pawel
    Krasnodebski, Maciej
    Wyporski, Anya
    Borkowski, Jan
    Lewandowski, Zbigniew
    Kobryn, Konrad
    Stankiewicz, Rafal
    Stypulkowski, Jan
    Holowko, Waclaw
    Patkowski, Waldemar
    Mielczarek-Puta, Magdalena
    Struga, Marta
    Szczepankiewicz, Benedykt
    Gornicka, Barbara
    Krawczyk, Marek
    ANNALS OF SURGERY, 2023, 278 (05) : 662 - 668
  • [4] Graft protection of the liver by hypothermic machine perfusion involves recovery of graft regeneration in rats
    Jia, Jun-Jun
    Xie, Hai-Yang
    Li, Jian-Hui
    He, Yong
    Jiang, Li
    He, Ning
    Zhou, Lin
    Wang, Weilin
    Zheng, Shu-Sen
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (01) : 427 - 437
  • [5] Hypothermic machine perfusion for liver graft preservation
    Amin, Arpit
    Panayotova, Guergana
    Guarrera, James V.
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2022, 27 (02) : 98 - 105
  • [6] Biomarkers of Liver Injury during Transplantation in an Era of Machine Perfusion
    Bhogal, Ricky H.
    Mirza, Darius F.
    Afford, Simon C.
    Mergental, Hynek
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (05)
  • [7] Assessment of liver graft quality during hypothermic oxygenated perfusion: The first international validation study
    Eden, Jahnina
    Thorne, Adam M.
    Bodewes, Silke B.
    Patrono, Damiano
    Roggio, Dorotea
    Breuer, Eva
    Lonati, Caterina
    Dondossola, Daniele
    Panayotova, Guergana
    Boteon, Amanda P. C. S.
    Walsh, Daniel
    Carvalho, Mauricio Flores
    Schurink, Ivo J.
    Ansari, Fariha
    Kollmann, Dagmar
    Germinario, Giuliana
    Garrido, Elisabeth Alexis Rivas
    Benitez, Julio
    Rebolledo, Rolando
    Cescon, Matteo
    Ravaioli, Matteo
    Berlakovich, Gabriela A.
    De Jonge, Jeroen
    Uluk, Deniz
    Lurje, Isabella
    Lurje, Georg
    Boteon, Yuri L.
    Guarrera, James, V
    Romagnoli, Renato
    Galkin, Alexander
    Meierhofer, David
    Porte, Robert J.
    Clavien, Pierre Alain
    Schlegel, Andrea
    de Meijer, Vincent E.
    Dutkowski, Philipp
    JOURNAL OF HEPATOLOGY, 2025, 82 (03)
  • [8] Hypothermic oxygenated perfusion for a steatotic liver graft
    Lai, Quirino
    Ruberto, Franco
    Melandro, Fabio
    Laureiro, Zoe Larghi
    Rossi, Massimo
    Mennini, Gianluca
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2020, 19 (01) : 88 - 90
  • [9] Effluent Molecular Analysis Guides Liver Graft Allocation to Clinical Hypothermic Oxygenated Machine Perfusion
    Lonati, Caterina
    Schlegel, Andrea
    Battistin, Michele
    Merighi, Riccardo
    Carbonaro, Margherita
    Dongiovanni, Paola
    Leonardi, Patrizia
    Zanella, Alberto
    Dondossola, Daniele
    BIOMEDICINES, 2021, 9 (10)
  • [10] Hypothermic oxygenated perfusion (HOPE) for fatty liver grafts in rats and humans
    Kron, Philipp
    Schlegel, Andrea
    Mancina, Leandro
    Clavien, Pierre-Alain
    Dutkowski, Philipp
    JOURNAL OF HEPATOLOGY, 2018, 68 (01) : 82 - 91