TLC vs. HPLC: A green comparison for veterinary drug analysis

被引:1
|
作者
Hemdan, Ahmed [1 ,2 ]
Ahmed, Naglaa [2 ]
Galal, Maha Mohammed [3 ]
Zaazaa, Hala Elsayed [3 ]
机构
[1] Kuwait Univ, Fac Pharm, Dept Pharmaceut Chem, Kuwait, Kuwait
[2] Ahram Canadian Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, 6th October, Egypt
[3] Cairo Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Cairo, Egypt
关键词
Lidocaine; Oxytetracycline; 6; dimethylaniline; TLC; HPLC; Greenness assessment; OXYTETRACYCLINE; PERFORMANCE; LIDOCAINE; MILK;
D O I
10.1016/j.microc.2024.112149
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes two analytical methods for determining lidocaine (LD) and oxytetracycline (OTC) in veterinary dosage form: a traditional Thin-Layer Chromatography (TLC) method and a more environmentally friendly Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method. Initially, the TLC method was used due to its speed, simplicity, and accuracy. It successfully separated LD and OTC in veterinary dosage forms with a linearity range of 0.5-11.0 mu g/band for LD and 4.0-34.0 mu g/band for OTC. However, TLC proved to be inadequate for resolving the binary mixture in the presence of toxic lidocaine impurity (2,6-dimethylaniline) (DMA), and was less environmentally friendly. Consequently, an RP-HPLC method was developed using a C18 column and a mobile phase consisting of ethanol and phosphate buffer (pH 7) in a 70:30 ratio, with a flow rate of 1.0 mL/min. This method effectively separated OTC, LD and DMA, using a PDA detector at wavelengths of 272, 232, and 210 nm and with retention times of 1.529, 2.77, and 3.581 min for OTC, DMA, and LD respectively. The RP-HPLC method showed linearity ranges of 270.0-972.0 mu g/mL for OTC, 0.5-25.0 mu g/mL for DMA, and 5.0-18.0 mu g/mL for LD. Both methods were validated for linearity, precision, accuracy, robustness, detection limit, and quantitation limit. The greenness of each method was evaluated using NEMI, Eco-scale, and Agree tools, with results demonstrating the RP-HPLC method as the more environmentally sustainable method.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Chat GPT vs. Clinical Decision Support Systems in the Analysis of Drug-Drug Interactions
    Bischof, Thorsten
    al Jalali, Valentin
    Zeitlinger, Markus
    Jorda, Anselm
    Hana, Michelle
    Singeorzan, Karla-Nikita
    Riesenhuber, Nikolaus
    Stemer, Gunar
    Schoergenhofer, Christian
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2025, 117 (04) : 1142 - 1147
  • [42] THE ANALYSIS OF ANTHRAQUINONE IN PULPING LIQUORS AND PULP PRODUCTS BY HPLC AND TLC
    MORTIMER, RD
    FLEMING, BI
    TAPPI, 1981, 64 (11): : 114 - 116
  • [43] THE DEVELOPMENT AND APPLICATION OF COUPLED HPLC-TLC FOR PHARMACEUTICAL ANALYSIS
    BANKS, CT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) : 705 - 710
  • [44] Comparison of Outcomes Following a Switch from a Brand to an Authorized vs. Independent Generic Drug
    Hansen, Richard A.
    Qian, Jingjing
    Berg, Richard
    Linneman, James
    Seoane-Vazquez, Enrique
    Dutcher, Sarah
    Raofi, Saeid
    Peissig, Peggy
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2016, 25 : 602 - 603
  • [45] HPLC AND DRUG ANALYSIS
    STEWART, MJ
    CLINICAL CHEMISTRY, 1994, 40 (06) : 953 - 953
  • [46] DRUG ANALYSIS BY HPLC
    KARGER, BL
    GIESE, RW
    EKSTEEN, R
    TANAKA, N
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 6 - 6
  • [47] COMPARISON OF MULTIPLE SCLEROSIS DRUG PRICES IN SAUDI ARABIA VS. UNITED ARAB OF EMIRATES
    Turkistani, F.
    Bin Sawad, A.
    VALUE IN HEALTH, 2020, 23 : S271 - S271
  • [48] RP-HPLC and RP-TLC in the analysis of flavonoids
    Baranowski, R
    Kabut, J
    Baranowska, I
    CHEMIA ANALITYCZNA, 2005, 50 (01): : 301 - 313
  • [49] Comparison of Manual Vs. Semi-Automatic CBCT Image Analysis
    Claps, L.
    Alaei, P.
    MEDICAL PHYSICS, 2019, 46 (06) : E556 - E556
  • [50] MANET Routing Protocols vs. Mobility Models: Performance Analysis and Comparison
    Timcenko, Valentina
    Stojanovic, Mirjana
    Rakas, Slavica Bostjancic
    AIC '09: PROCEEDINGS OF THE 9TH WSEAS INTERNATIONAL CONFERENCE ON APPLIED INFORMATICS AND COMMUNICATIONS: RECENT ADVANCES IN APPLIED INFORMAT AND COMMUNICATIONS, 2009, : 271 - +