On the optical response of novel coumarin-fused NIR BODIPY dyes to X-rays

被引:0
作者
Lifanovsky, Nikita [1 ,2 ]
Spector, Daniil [3 ,4 ]
Egorov, Anton [1 ]
Mazur, Dmitrii [3 ]
Bubley, Anna [3 ]
Belousov, Alexandr [1 ,5 ]
Klimovich, Mikhail [1 ]
Kostyukov, Alexey [1 ]
Kolyvanova, Maria [1 ,5 ]
Beloglazkina, Elena [3 ]
Kuzmin, Vladimir [1 ]
Krasnovskaya, Olga [3 ,4 ]
Morozov, Vladimir [1 ]
机构
[1] Russian Acad Sci, Emanuel Inst Biochem Phys, 4 Kosygina, Moscow 119334, Russia
[2] Natl Res Nucl Univ MEPhI, 31 Kashirskoe Sh, Moscow 115409, Russia
[3] Lomonosov Moscow State Univ, Dept Chem, Leninskie Gory 1,3, Moscow 119991, Russia
[4] Natl Univ Sci & Technol MISIS, Dept Mat Sci Semicond & Dielect, Leninskiy Prospect 4, Moscow 101000, Russia
[5] Fed Med Biol Agcy Russian Federat, Burnazyan Fed Med Biophys Ctr, 23 Marshala Novikova, Moscow 123182, Russia
基金
俄罗斯科学基金会;
关键词
BODIPY; Dyes; Dosimetry; Radiation detection; Fluorescence; X-ray; LOW-DOSE DETECTION; GAMMA-RADIATION; IONIZING-RADIATION; RADIOLYSIS; DOSIMETRY; CHLOROFORM; CHEMISTRY; MECHANISM; SOLVENTS; DEGRADATION;
D O I
10.1016/j.saa.2024.125227
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This paper reports synthesis and characterization of three new coumarin-fused NIR BODIPY dyes 16-18, - 18 , as well as the detailed study of their optical response to exposure with X-rays (up to 1000 Gy) in solvents of various nature. A strong reaction to irradiation (both in terms of absorption and fluorescence changing) is found in chlorinated solvents (CCl4 4 and CHCl3) 3 ) and acetonitrile, while no significant respond of the dyes is observed in toluene and propanol-1. Herewith, their responses turned out to be very versatile: a complex change in fluorescence (quenching of the main band accompanied by the flare-up in a new spectral region) is observed together with colorimetric reaction (e.g., the color of 17 changes from green to blue at 50-80 Gy, and then becomes pink closer to approximate to 350 Gy). In general, the dyes show good linearity in their response to irradiation up to approximate to 70-100 Gy and are quite sensitive. For example, the limit of detection (LOD) values for 18 are from 0.29 to 6.73. At the same time, the ratiometric fluorescent response of the compound 16 turns out to be linear over the entire range up to 1000 Gy (to date, this is the first BODIPY-based X-ray probe with optical response over such a wide dose range). Thus, the synthesized dyes seem to be promising for dosimetric support of radiation processing/sterilization procedures.
引用
收藏
页数:16
相关论文
共 78 条
  • [1] RADIOLYSIS OF LIQUID CHLOROFORM IN AN OXYGEN FREE ATMOSPHERE
    ABADIE, MJM
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1982, 19 (01): : 63 - 71
  • [2] Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
    Adamovics, J.
    Maryanski, M. J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 107 - 112
  • [3] A Fluorescent Visual Proton Donor and Photoacid Sterilant Based on Sulfonate-conjugated BODIPY
    Ali, Abbas Mohammed
    Shao, Jian
    Wang, Jia-Xin
    Chen, Qiu-Yun
    Li, Yang
    Qu, Ling-Ling
    [J]. JOURNAL OF FLUORESCENCE, 2021, 31 (02) : 501 - 507
  • [4] BODIPY Conjugates as Functional Compounds for Medical Diagnostics and Treatment
    Antina, Elena
    Bumagina, Natalia
    Marfin, Yuriy
    Guseva, Galina
    Nikitina, Liliya
    Sbytov, Dmitry
    Telegin, Felix
    [J]. MOLECULES, 2022, 27 (04):
  • [5] Gamma radiation induced degradation of anthraquinone Reactive Blue-19 dye using hydrogen peroxide as oxidizing agent
    Arshad, Rabia
    Bokhari, Tanveer H.
    Khosa, Kaleem K.
    Bhatti, Ijaz A.
    Munir, Majid
    Iqbal, Mazhar
    Iqbal, Dure N.
    Khan, M. I.
    Iqbal, Munawar
    Nazir, Arif
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [6] AQUEOUS COUMARIN SYSTEM AS A LOW RANGE CHEMICAL DOSIMETER
    ASHAWA, SC
    KINI, UR
    MADHVANATH, U
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1979, 30 (01): : 7 - 10
  • [7] GAMMA RADIOLYSIS OF ACETONITRILE
    AYSCOUGH, PB
    DRAWE, H
    KOHLER, P
    [J]. RADIATION RESEARCH, 1968, 33 (02) : 263 - &
  • [8] Modulation of the photophysical properties of BODIPY dyes by substitution at their meso position.
    Banuelos, Jorge
    Arroyo-Cordoba, Ismael J.
    Valois-Escamilla, Ismael
    Alvarez-Hernandez, Alejandro
    Pena-Cabrera, Eduardo
    Hu, Rongrong
    Tang, Ben Zhong
    Esnal, Ixone
    Martinez, Virginia
    Lopez Arbeloa, Inigo
    [J]. RSC ADVANCES, 2011, 1 (04) : 677 - 684
  • [9] Use of some organic dyes in gamma irradiation dose determination
    Barakat, M. F.
    El-Banna, M.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (02) : 367 - 375
  • [10] Radiation effects on some dyes in non-aqueous solvents and in some polymeric films
    Barakat, MF
    El-Salamawy, K
    El-Banna, M
    Abdel-Hamid, M
    Taha, AAR
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (02) : 129 - 136