The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

被引:0
|
作者
Tabucol, Johnnidel [1 ]
Kooiman, Vera G. M. [2 ,3 ]
Leopaldi, Marco [1 ]
Leijendekkers, Ruud [4 ,5 ]
Selleri, Giacomo [1 ]
Mellini, Marcello [1 ]
Verdonschot, Nico [6 ,7 ]
Oddsson, Magnus [8 ]
Carloni, Raffaella [9 ]
Zucchelli, Andrea [1 ]
Brugo, Tommaso M. [1 ]
机构
[1] Univ Bologna, Dept Ind Engn, I-40131 Bologna, Italy
[2] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, Dept Rehabil, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Radboud Inst Hlth Sci, Orthoped Res Lab,Dept Rehabil,Med Ctr, NL-6500 HB Nijmegen, Netherlands
[5] Radboud Univ Nijmegen, Med Ctr, IQ Healthcare, NL-6500 HB Nijmegen, Netherlands
[6] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, NL-6500 HB Nijmegen, Netherlands
[7] Univ Twente, Fac Engn & Technol, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
[8] Ossur, IS-110 Reykjavik, Iceland
[9] Univ Groningen, Fac Sci & Engn, Dept Artificial Intelligence, Bernoulli Inst Math Comp Sci & Artificial Intelli, Groningen, Netherlands
关键词
Foot; Prosthetics; Legged locomotion; Ankle; Particle measurements; Force; Atmospheric measurements; Costs; Blades; Biomechanics; Amputation; biomechanical tests; prosthesis design; prosthetic feet; variable stiffness; TRANSTIBIAL AMPUTEES; POWERED KNEE; WALKING; AMPUTATION; DESIGN; ACTUATOR; FEET;
D O I
10.1109/TNSRE.2025.3534096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex- zeta , an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex- zeta adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant's results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex- zeta offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex- zeta could mark significant progress in prosthesis technology.
引用
收藏
页码:653 / 663
页数:11
相关论文
共 50 条
  • [21] A PASSIVE TWO-DEGREE-OF-FREEDOM ANKLE-FOOT PROSTHESIS
    Elley, Colin
    Nelson, Carl A.
    2018 DESIGN OF MEDICAL DEVICES CONFERENCE, 2018,
  • [22] A Study of Human Walking Biomechanics for Ankle-Foot Prosthesis Design
    Fandakli, Selin Aydin
    Okumus, Halil Ibrahim
    Ozturk, Mehmet
    2018 6TH INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING & INFORMATION TECHNOLOGY (CEIT), 2018,
  • [23] Design, Control, and Evaluation of a Robotic Ankle-Foot Prosthesis Emulator
    Anderson, Anthony J.
    Hudak, Yuri F.
    Muir, Brittney C.
    Aubin, Patrick M.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2023, 5 (03): : 741 - 752
  • [24] Biomechanics of the ankle-foot system during stair ambulation: Implications for design of advanced ankle-foot prostheses
    Sinitski, Emily H.
    Hansen, Andrew H.
    Wilken, Jason M.
    JOURNAL OF BIOMECHANICS, 2012, 45 (03) : 588 - 594
  • [25] The influence of push-off timing in a robotic ankle-foot prosthesis on the energetics and mechanics of walking
    Malcolm, Philippe
    Quesada, Roberto E.
    Caputo, Joshua M.
    Collins, Steven H.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2015, 12
  • [26] A low-power ankle-foot prosthesis for push-off enhancement
    Mazzarini, Alessandro
    Fantozzi, Matteo
    Papapicco, Vito
    Fagioli, Ilaria
    Lanotte, Francesco
    Baldoni, Andrea
    Dell'Agnello, Filippo
    Ferrara, Paolo
    Ciapetti, Tommaso
    Molino Lova, Raffaele
    Gruppioni, Emanuele
    Trigili, Emilio
    Crea, Simona
    Vitiello, Nicola
    WEARABLE TECHNOLOGIES, 2023, 4
  • [27] An Ankle-Foot Prosthesis Emulator With Control of Plantarflexion and Inversion-Eversion Torque
    Kim, Myunghee
    Chen, Tianjian
    Chen, Tianyao
    Collins, Steven H.
    IEEE TRANSACTIONS ON ROBOTICS, 2018, 34 (05) : 1183 - 1194
  • [28] Bionic ankle-foot prosthesis normalizes walking gait for persons with leg amputation
    Herr, Hugh M.
    Grabowski, Alena M.
    PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2012, 279 (1728) : 457 - 464
  • [29] Design of a Quasi-Passive Ankle-Foot Orthosis with Customizable, Variable Stiffness
    Van Crey, Nikko
    Cavallin, Marcos
    Shepherd, Max
    Rouse, Elliott J.
    2023 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, ICORR, 2023,
  • [30] Multiplanar Stiffness of Commercial Carbon Composite Ankle-Foot Orthoses
    Shuman, Benjamin R.
    Russell Esposito, Elizabeth
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (01):