The MyFlex-ζ Foot: A Variable Stiffness ESR Ankle-Foot Prosthesis

被引:0
|
作者
Tabucol, Johnnidel [1 ]
Kooiman, Vera G. M. [2 ,3 ]
Leopaldi, Marco [1 ]
Leijendekkers, Ruud [4 ,5 ]
Selleri, Giacomo [1 ]
Mellini, Marcello [1 ]
Verdonschot, Nico [6 ,7 ]
Oddsson, Magnus [8 ]
Carloni, Raffaella [9 ]
Zucchelli, Andrea [1 ]
Brugo, Tommaso M. [1 ]
机构
[1] Univ Bologna, Dept Ind Engn, I-40131 Bologna, Italy
[2] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, Dept Rehabil, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Donders Inst Brain Cognit & Behav, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Donders Inst Brain Cognit & Behav, Radboud Inst Hlth Sci, Orthoped Res Lab,Dept Rehabil,Med Ctr, NL-6500 HB Nijmegen, Netherlands
[5] Radboud Univ Nijmegen, Med Ctr, IQ Healthcare, NL-6500 HB Nijmegen, Netherlands
[6] Radboud Univ Nijmegen, Med Ctr, Orthoped Res Lab, NL-6500 HB Nijmegen, Netherlands
[7] Univ Twente, Fac Engn & Technol, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
[8] Ossur, IS-110 Reykjavik, Iceland
[9] Univ Groningen, Fac Sci & Engn, Dept Artificial Intelligence, Bernoulli Inst Math Comp Sci & Artificial Intelli, Groningen, Netherlands
关键词
Foot; Prosthetics; Legged locomotion; Ankle; Particle measurements; Force; Atmospheric measurements; Costs; Blades; Biomechanics; Amputation; biomechanical tests; prosthesis design; prosthetic feet; variable stiffness; TRANSTIBIAL AMPUTEES; POWERED KNEE; WALKING; AMPUTATION; DESIGN; ACTUATOR; FEET;
D O I
10.1109/TNSRE.2025.3534096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most commercially available foot prostheses are passive ESR feet, which store and release energy to reduce metabolic costs and improve comfort but cannot adjust to varying walking conditions. In contrast, bionic feet adapt to different tasks but are hindered by high weight, power consumption, and cost. This paper presents MyFlex- zeta , an ESR foot with a variable stiffness system, as a compromise between these two categories. MyFlex- zeta adjusts stiffness by varying the sagittal-plane distance between two key points, altering force interactions within the prosthesis and affecting overall stiffness. Clinical tests with three transfemoral amputees evaluated stiffness variation across two sessions: the first subjective, where participants assessed stiffness settings during different tasks, and the second biomechanical, measuring performance parameters. Two participants selected different stiffness settings for various tasks, while the third, with limited perception of stiffness changes, showed less distinction in outcomes. Greater sagittal-plane rotation and higher energy absorption were observed in most tasks with more compliant settings, although one participant's results were limited due to selecting close stiffness settings. Overall, these findings suggest MyFlex- zeta offers adaptability and performance improvements over traditional ESR feet. With further actuation and control system development, MyFlex- zeta could mark significant progress in prosthesis technology.
引用
收藏
页码:653 / 663
页数:11
相关论文
共 50 条
  • [1] The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness
    Shepherd, Max K.
    Rouse, Elliott J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (12) : 2375 - 2386
  • [2] An Ankle-Foot Prosthesis for Rock Climbing Augmentation
    Rogers, Emily A.
    Carney, Matthew E.
    Yeon, Seong Ho
    Clites, Tyler R.
    Solav, Dana
    Herr, Hugh M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 41 - 51
  • [3] Powered ankle-foot prosthesis
    Biomechatronics Group, MIT Media Lab., Cambridge, MA 02139, United States
    IEEE Rob Autom Mag, 2008, 3 (52-59): : 52 - 59
  • [4] Design and Mechanical Characterization of a Variable Stiffness ESR Foot Prosthesis
    Tabucol, Johnnidel
    Leopaldi, Marco
    Brugo, Tommaso Maria
    Oddsson, Magnus
    Zucchelli, Andrea
    IEEE ACCESS, 2024, 12 : 97544 - 97556
  • [5] Biologically Inspired Design and Development of a Variable Stiffness Powered Ankle-Foot Prosthesis
    Agboola-Dobson, Alexander
    Wei, Guowu
    Ren, Lei
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2019, 11 (04):
  • [6] Teleoperation of an Ankle-Foot Prosthesis With a Wrist Exoskeleton
    Welker, Cara G.
    Chiu, Vincent L.
    Voloshina, Alexandra S.
    Collins, Steven H.
    Okamura, Allison M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (05) : 1714 - 1725
  • [7] Design and development of ankle-foot prosthesis with delayed release of plantarflexion
    Mitchell, Michael
    Craig, Katelynn
    Kyberd, Peter
    Biden, Edmund
    Bush, Greg
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2013, 50 (03) : 409 - 422
  • [8] A Compact, Lightweight Robotic Ankle-Foot Prosthesis: Featuring a Powered Polycentric Design
    Gabert, Lukas
    Hood, Sarah
    Minh Tran
    Cempini, Marco
    Lenzi, Tommaso
    IEEE ROBOTICS & AUTOMATION MAGAZINE, 2020, 27 (01) : 87 - 102
  • [9] Evaluation of an articulated passive ankle-foot prosthesis
    Lathouwers, Elke
    Ampe, Toon
    Diaz, Maria Alejandra
    Meeusen, Romain
    De Pauw, Kevin
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [10] DEVELOPMENT OF AN ANKLE-FOOT PROSTHESIS FOR PHYSICAL THERAPY
    Nickel, Eric
    Voss, Gregory
    Hansen, Andrew
    Koehler-McNicholas, Sara
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,