Multi-angle acquisition and 3D composite reconstruction for organ-targeted PET using planar detectors

被引:0
|
作者
Shahi, Anirudh [1 ]
Poladyan, Harutyun [1 ]
Anashkin, Edward [2 ]
Komarov, Borys [2 ]
Baldassi, Brandon [2 ]
Rapley, Madeline [1 ]
Babich, Alexey [2 ]
Bubon, Oleksandr [1 ,2 ]
Reznik, Alla [1 ,3 ]
机构
[1] Lakehead Univ, Dept Phys, Thunder Bay, ON, Canada
[2] Radialis Inc, Thunder Bay, ON, Canada
[3] Thunder Bay Reg Hlth Res Inst, Thunder Bay, ON, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
brain PET; breast PET; organ-targeted; planar detectors; PET; DEDICATED BREAST; LIMITED ANGLE; HUMAN BRAIN; DESIGN; PERFORMANCE; SCANNER;
D O I
10.1002/mp.17606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThis study investigates a multi-angle acquisition method aimed at improving image quality in organ-targeted PET detectors with planar detector heads. Organ-targeted PET technologies have emerged to address limitations of conventional whole-body PET/CT systems, such as restricted axial field-of-view (AFOV), limited spatial resolution, and high radiation exposure associated with PET procedures. The AFOV in organ-targeted PET can be adjusted to the organ of interest, minimizing unwanted signals from other parts of the body, thus improving signal collection efficiency and reducing the dose of administered radiotracer. However, while planar detector PET technology allows for quasi-3D image reconstruction due to the separation between detector heads, it suffers from degraded axial spatial resolution and, consequently, reduced recovery coefficients (RCs) along the axial direction perpendicular to the detectors.PurposeThe purpose of this study was to evaluate the concept of multi-angle image acquisition with two planar PET detectors and composite full 3D image reconstruction. This leverages data collection from multiple polar angles to improve the axial spatial resolution in the direction perpendicular to the detector heads. In such, the concept allows to overcome the intrinsic limitations of planar detectors in axial resolution.MethodsThis study evaluates the improvement in the quality of images acquired with the Radialis organ-targeted PET camera through multi-angle image acquisition, in both experimental and simulated imaging scenarios. This includes the use of custom-made phantom with fillable spherical hot inserts, the NEMA NU4-2008 image quality (IQ) phantom, and simulations with a digital brain phantom. The analysis involves the comparison of line profiles drawn through the spherical hot inserts, image uniformity, RCs, and the reduction of smearing observed in the axial planes with and without the multi-angle acquisition strategy.ResultsSignificant improvements were observed in reducing smearing, enhancing image uniformity, and increasing RCs using the evaluated multi-angle acquisition method. In the composite images, the hot spheres appear more symmetrical in all planes. The image uniformity, calculated from the IQ phantom, improves from 7.79% and 10.98%, as measured in the images from the individual acquisitions, to 2.72% in the composite image. There is also an overall improvement in the RCs as measured from the hot rods of the IQ phantom. Furthermore, the simulation study using the digital human brain phantom demonstrates minimal smearing in the four-angle scan, as opposed to a two-angle scan.ConclusionThe multi-angle acquisition method offers a promising approach to transform planar PET detector technology into a true tomographic organ-targeted PET system and to enable improvement in image quality while preserving a versatility inherent to planar detector technology. Future research will focus on optimizing the multi-angle imaging protocol, including adjustments to detector separations, number of acquisition angles, and reconstruction iterations, alongside incorporating TOF, and reconstruction with point spread function modeling to further improve image quality.
引用
收藏
页数:13
相关论文
共 14 条
  • [1] Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA
    Cui, Jing-yu
    Pratx, Guillem
    Prevrhal, Sven
    Levin, Craig S.
    MEDICAL PHYSICS, 2011, 38 (12) : 6775 - 6786
  • [2] A 3D k-space Fourier encoding and reconstruction framework for simultaneous multi-slab acquisition
    Dai, Erpeng
    Wu, Yuhsuan
    Wu, Wenchuan
    Guo, Rui
    Liu, Simin
    Miller, Karla L.
    Zhang, Zhe
    Guo, Hua
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1012 - 1024
  • [3] Accuracy of 3D acquisition mode for myocardial FDG PET studies using a BGO-based scanner
    van der Weerdt, Arno P.
    Boellaard, Ronald
    Visser, Frans C.
    Lammertsma, Adriaan A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (09) : 1439 - 1446
  • [4] Accuracy of 3D acquisition mode for myocardial FDG PET studies using a BGO-based scanner
    Arno P. van der Weerdt
    Ronald Boellaard
    Frans C. Visser
    Adriaan A. Lammertsma
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1439 - 1446
  • [5] Multi-view 3D scene reconstruction using ant colony optimization techniques
    Chrysostomou, Dimitrios
    Gasteratos, Antonios
    Nalpantidis, Lazaros
    Sirakoulis, Georgios C.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (11)
  • [6] A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors
    Zeng, Tianyi
    Gao, Juan
    Gao, Dongfang
    Kuang, Zhonghua
    Sang, Ziru
    Wang, Xiaohui
    Hu, Lingzhi
    Chen, Qun
    Chu, Xu
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [7] A feasibility study of the 3D fluorescent image reconstruction for the simultaneous PET and fluorescent CT Imaging system using depth of interaction PET detector
    Tashima, Hideaki
    Obi, Takashi
    Yamaya, Taiga
    Murayama, Hideo
    Kitamura, Keiji
    Oda, Ichiro
    Yamaguchi, Masahiro
    Ohyama, Nagaaki
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [8] Efficient 3D TOF PET Reconstruction Using View-Grouped Histo-Images: DIRECT - Direct Image Reconstruction for TOF
    Matej, Samuel
    Jayanthi, Shridhar
    Surti, Suleman
    Daube-Witherspoon, Margaret E.
    Muehllehner, Gerd
    Karp, Joel S.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1728 - 1735
  • [9] Unsupervised 3D PET-CT Image Registration Method Using a Metabolic Constraint Function and a Multi-Domain Similarity Measure
    Yu, Hengjian
    Jiang, Huiyan
    Zhou, Xiangrong
    Hara, Takeshi
    Yao, Yu-Dong
    Fujita, Hiroshi
    IEEE ACCESS, 2020, 8 (08): : 63077 - 63089
  • [10] Simulation study on 3D convolutional neural networks for time-of-flight prediction in monolithic PET detectors using digitized waveforms
    Maebe, Jens
    Vandenberghe, Stefaan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12):