Near Real-Time Measurement of Airborne Carbon Nanotubes with Metals Using Raman-Spark Emission Spectroscopy

被引:1
作者
Zheng, Lina [1 ]
Li, Jialin [2 ]
Huang, Jing [2 ]
Feng, Wenting [2 ]
Zhan, Yuhan [3 ]
Liu, Dou [1 ]
机构
[1] China Univ Min & Technol, Jiangsu Engn Res Ctr Dust Control & Occupat Protec, Xuzhou, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Safety Engn, Xuzhou 221116, Jiangsu, Peoples R China
[3] China Univ Min & Technol, Sch Architecture & Design, Xuzhou, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon nanotubes; CNT; Raman spectroscopy; spark emission spectroscopy; INDUCED BREAKDOWN SPECTROSCOPY; TOXICITY; PIGMENTS;
D O I
10.1177/00037028241307258
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a near real-time measurement method that combines Raman and spark emission spectroscopy to quantitatively analyze the molecular structure of airborne single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs), as well as detect toxic metals within CNTs. A corona-based aerosol microconcentrator was used for airborne CNTs sampling to enhance the measurement accuracy and sensitivity. The intensity of the characteristic Raman bands of CNTs and atomic emission lines of metals exhibited a linear relationship with the analyte mass, yielding high coefficient R2 values. By carefully selecting appropriate signal peaks for calibration, we achieved a limit of detection (LOD) in terms of air concentration as low as 0.09 mu g/m3 for SWCNT and 0.81 mu g/m3 for MWCNT with a sampling time of 10 min. Additionally, our method exhibited excellent performance in measuring metals, with a mass LOD of 0.8-0.9 ng for Co and Ni and a mass LOD of 35.09 ng for Fe. The method performed well for the measurement of CNT and relevant metal composition with advantages of near real-time monitoring, low LOD, and portable use, making it a valuable tool for various applications in nanomaterial analysis.
引用
收藏
页数:10
相关论文
共 47 条
[1]  
[Anonymous], Current Intelligence Bulletin 63: Occupational Exposure to Titanium Dioxide
[2]  
Ashley K, 2017, NIOSH manual of analytical methods (NMAM), VFifth
[3]  
ASTM International, 2014, D7948-20: Standard Test Method for Measurement of Respirable Crystalline Silica in Workplace Air by Infrared Spectrometry
[4]  
Aylward G., 2008, SI CHEM DATA
[5]  
Birch M.E., Analysis of Carbon Nanotubes and Nanofibers on Mixed Cellulose Ester Filters by Transmission Electron Microscopy
[6]   Use of Raman spectroscopy to identify carbon nanotube contamination at an analytical balance workstation [J].
Braun, Elizabeth I. ;
Huang, An ;
Tusa, Carolyn A. ;
Yukica, Michael A. ;
Pantano, Paul .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (12) :915-923
[7]   An example of the complementarity of laser-induced breakdown spectroscopy and Raman microscopy for wall painting pigments analysis [J].
Bruder, Romain ;
Detalle, Vincent ;
Coupry, Claude .
JOURNAL OF RAMAN SPECTROSCOPY, 2007, 38 (07) :909-915
[8]   Analysis of pigments in polychromes by use of laser induced breakdown spectroscopy and Raman microscopy [J].
Castillejo, M ;
Martín, M ;
Silva, D ;
Stratoudaki, T ;
Anglos, D ;
Burgio, L ;
Clark, RJH .
JOURNAL OF MOLECULAR STRUCTURE, 2000, 550 :191-198
[9]   Contemporary review on carbon nanotube (CNT) composites and their impact on multifarious applications [J].
Choudhary, Megha ;
Sharma, Aaruni ;
Raj, S. Aravind ;
Sultan, Mohamed Thariq Hameed ;
Hui, David ;
Shah, Ain Umaira Md .
NANOTECHNOLOGY REVIEWS, 2022, 11 (01) :2632-2660
[10]  