Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise

被引:1
作者
Corral-Perez, Juan [1 ]
Marin-Galindo, Alberto [1 ]
Costilla, Manuel [1 ]
Casals, Cristina [1 ]
Munoz-Lopez, Alejandro [2 ,3 ]
Sanchez-Sixto, Alberto [1 ]
Sanudo, Borja [4 ]
Ponce-Gonzalez, Jesus Gustavo [1 ]
机构
[1] Univ Cadiz, Inst Invest Innovac Biomed Cadiz INiB, Dept Phys Educ, ExPhy Res Grp, Cadiz, Spain
[2] Univ Seville, Dept Motricidad Humana & Rendimiento Deport, Seville, Spain
[3] CEU San Pablo Cardenal Spinola Univ, Sport Dept, Madrid, Spain
[4] Univ Seville, Dept Phys Educ & Sport, Seville, Spain
关键词
NIRS; Exercise prescription; Resistance training; Full squat; Hypertrophy; RESISTANCE EXERCISE; BLOOD-FLOW; HORMONE;
D O I
10.1016/j.jsams.2024.07.006
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Monitoring of changes in skeletal muscle oxygenation during exercise has increased in recent years. Tissue oxygenation, which is related to fatigue and muscle hypertrophy, is often measured using near-infrared spectroscopy (NIRS). Objectives: This study aimed to determine the test-retest reliability of a non-portable NIRS (NIRO200Nx) during the full-squat exercise and recovery in young healthy men. Design: Twenty-five male participants (21.8 +/- 2.6 years) were recruited for this original research. Each participant completed an 8-repetition test with a load that elicited a velocity of 1 m<middle dot>s-1. The test was conducted twice, with a 48-hour washout period between sessions. Methods: The NIRS measured the changes of oxygenated-Hemoglobin (O2Hb), deoxygenated-Hemoglobin (HHb) and Tissue Oxygenation Index (TOI) in both Vastus Lateralis and Vastus Medialis during rest, exercise, and recovery. Coefficient of Variation (CV), Standard Error Measurement (SEM) and Intraclass Correlation Coefficient (ICC) were used to evaluate the reliability of the data. Significance was set at p < 0.05. Results: The results indicated that TOI had good to acceptable absolute reliability (CVTOI = 2.7-10.2 %). A good relative relativity for the overall test was found for Vastus Medialis O2Hb (ICC = 0.851), HHb (ICC = 0.852), and TOI (ICC = 0.864), and Vastus Lateralis O2Hb (ICC = 0.898), HHb (ICC = 0.899), and TOI (ICC = 0.897). Conclusions: We conclude that NIRO200Nx is a reliable instrument for measuring muscle oxygen saturation through the TOI parameter in not-to-failure dynamic resistance exercises (1 set of 8 reps against similar to 40 % 1 repetition maximum). Tissue oxygenation assessment could be a new way of individualizing exercise through dynamic resistance exercises.
引用
收藏
页码:805 / 813
页数:9
相关论文
共 35 条
[21]   Effects of velocity loss during resistance training on athletic performance, strength gains and muscle adaptations [J].
Pareja-Blanco, F. ;
Rodriguez-Rosell, D. ;
Sanchez-Medina, L. ;
Sanchis-Moysi, J. ;
Dorado, C. ;
Mora-Custodio, R. ;
Yanez-Garcia, J. M. ;
Morales-Alamo, D. ;
Perez-Suarez, I. ;
Calbet, J. A. L. ;
Gonzalez-Badillo, J. J. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2017, 27 (07) :724-735
[22]   Velocity Loss as a Critical Variable Determining the Adaptations to Strength Training [J].
Pareja-Blanco, Fernando ;
Alcazar, Julian ;
Sanchez-Valdepenas, Juan ;
Cornejo-Daza, Pedro J. ;
Piqueras-Sanchiz, Francisco ;
Mora-Vela, Raul ;
Sanchez-Moreno, Miguel ;
Bachero-Mena, Beatriz ;
Ortega-Becerra, Manuel ;
Alegre, Luis M. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (08) :1752-1762
[23]   Muscle Oximetry in Sports Science: An Updated Systematic Review [J].
Perrey, Stephane ;
Quaresima, Valentina ;
Ferrari, Marco .
SPORTS MEDICINE, 2024, 54 (04) :975-996
[24]   Muscle Oximetry in Sports Science: A Systematic Review [J].
Perrey, Stephane ;
Ferrari, Marco .
SPORTS MEDICINE, 2018, 48 (03) :597-616
[25]   Reduced leg blood flow during dynamic exercise in older endurance-trained men [J].
Proctor, DN ;
Shen, PH ;
Dietz, NM ;
Eickhoff, TJ ;
Lawler, LA ;
Ebersold, EJ ;
Loeffler, DL ;
Joyner, MJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (01) :68-75
[26]   Velocity Loss as an Indicator of Neuromuscular Fatigue during Resistance Training [J].
Sanchez-Medina, Luis ;
Jose Gonzalez-Badillo, Juan .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (09) :1725-1734
[27]   Reliability of telemetric electromyography and near-infrared spectroscopy during high-intensity resistance exercise [J].
Scott, Brendan R. ;
Slattery, Katie M. ;
Sculley, Dean V. ;
Lockie, Robert G. ;
Dascombe, Ben J. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (05) :722-730
[28]   EFFECTS OF L-CARNITINE L-TARTRATE SUPPLEMENTATION ON MUSCLE OXYGENATION RESPONSES TO RESISTANCE EXERCISE [J].
Spiering, Barry A. ;
Kraemer, William J. ;
Hatfield, Disa L. ;
Vingren, Jakob L. ;
Fragala, Maren S. ;
Ho, Jen-Yu ;
Thomas, Gwendolyn A. ;
Hakkinen, Keijo ;
Volek, Jeff S. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2008, 22 (04) :1130-1135
[29]   Evaluation of different near-infrared spectroscopy technologies for assessment of tissue oxygen saturation during a vascular occlusion test [J].
Steenhaut, Kevin ;
Lapage, Koen ;
Bove, Thierry ;
De Hert, Stefan ;
Moerman, Annelies .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (06) :1151-1158
[30]  
Taelman J, 2011, Estimation of Muscle Fatigue Using Surface Electromyography and Near-infrared Spectroscopy, P353